Difference between revisions of "VTube-LASER v1.81"
From ATTWiki
(→New Winton ECNC 4 Bender Correction) |
(→New Winton ECNC 4 Bender Setup and Correction) |
||
(17 intermediate revisions by one user not shown) | |||
Line 18: | Line 18: | ||
* See [http://www.advancedtubular.com/customers/vtube VTube-LASER Customer Support Page] to download the latest version. | * See [http://www.advancedtubular.com/customers/vtube VTube-LASER Customer Support Page] to download the latest version. | ||
− | <br><br> | + | <br> |
+ | |||
+ | ===New Winton ECNC 4 Bender Setup and Correction=== | ||
+ | <table> | ||
+ | <tr> | ||
+ | <td width=300 valign=top> | ||
+ | [[image:winton_logo.jpg|300px]]<br> | ||
+ | [[image:winton_bender.jpg|300px]]<br> | ||
+ | *This version can read and write ECNC version 4 offline program files. | ||
+ | *Every value that can be setup in ECNC can also be setup in VTube-LASER. | ||
+ | </td> | ||
+ | <td valign=top> | ||
+ | [[image:winton_ecnc_4_screen.jpg|400px]]<br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <table> | ||
+ | <tr> | ||
+ | <td width=300 valign=top> | ||
+ | [[image:vtubelaser_winton_ecnc_4_wholescreen2.jpg|400px]] | ||
+ | <br> | ||
+ | </td> | ||
+ | <td valign="top"> | ||
+ | [[image:vtubelaser_winton_ecnc_4_screen.jpg|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
===New Separate Report Template Setup for STEP and LASER=== | ===New Separate Report Template Setup for STEP and LASER=== | ||
Line 24: | Line 51: | ||
*Some report templates are only appropriate in LASER because LASER handles inspections. | *Some report templates are only appropriate in LASER because LASER handles inspections. | ||
*Now the setup of each is stored separately. | *Now the setup of each is stored separately. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
<br> | <br> | ||
Latest revision as of 01:55, 19 January 2013
Revision 1.81
|
- See VTube-LASER Customer Support Page to download the latest version.
New Winton ECNC 4 Bender Setup and Correction
|
New Separate Report Template Setup for STEP and LASER
- Previous versions had identical setups in both modes.
- Some report templates are only appropriate in LASER because LASER handles inspections.
- Now the setup of each is stored separately.
New Supravision Project Wall Thickness Import/Output
- Previous versions did not save the wall thickness
- This version imports and exports the wall thickness value.
New Supravision Project Qualification Tolerance Envelopes Import/Export
- This version now imports and exports these values:
- Default Qualification Envelope Tolerance
- A End Length Qualification Tolerance
- B End Length Qualification Tolerance
- A End Angle Qualification Tolerance
- B End Angle Qualification Tolerance
New Inspection Grid Row Count Control
- VTube now controls the INSPECTION grid row count with the MASTER data row count rather than the MEASURED data row count.
- This allows the grid to be populated even if the Measured data is cleared.
Other Pages
- Back to the VTube-LASER page
- See VTube-LASER Customer Support Page to download the latest version.