Difference between revisions of "TubeCAD Pro v8-20130304"
From ATTWiki
(21 intermediate revisions by one user not shown) | |||
Line 23: | Line 23: | ||
<td> | <td> | ||
[[image:tcadpro_xlsio.jpg|300px]]<br> | [[image:tcadpro_xlsio.jpg|300px]]<br> | ||
+ | [[image:tcadpro_excelrunning.jpg|300px]]<br> | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 29: | Line 30: | ||
<br> | <br> | ||
− | + | ===[[image:Check.jpg|25px]] NEW: Command "PointLabelSpacing" controls point LABEL offset=== | |
− | ===[[image:Check.jpg|25px]] | + | |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
− | |||
− | |||
− | |||
− | |||
<td width=300> | <td width=300> | ||
+ | TubeCAD can moves the point labels from on top of the points to outside the diameter automatically.<br><br> | ||
+ | The direction is always along a vector formed by the bisection of the two adjacent centerlines - toward the outside of the bend.<br><br> | ||
+ | [[image:tcadpro_pointlabel_vector.jpg|300px]]<br><br> | ||
+ | The automatic distance is always tied to the diameter entered in General Specs.<br><br> | ||
+ | Because of this new capability, users asked us to allow them to control how far the labels move away from the actual point object.<br><br> | ||
+ | This new command allows you to type a factor (multiplier) that will change the distance by multiplying the factor against the automatic distance generated.<br><br> | ||
+ | A value of 1.0 makes no change in the value. But a value of 0.5 moves the label halfway closer to the point it is labelling.<br><br> | ||
+ | This value affects all labels on all objects - not just the primary views.</td> | ||
+ | <td width=300> | ||
+ | [[image:tcadpro_pointlabelspacing_factor1.jpg|300px]]<br>Factor of "1"<br><br> | ||
+ | [[image:tcadpro_pointlabelspacing_factor.5.jpg|300px]] | ||
+ | <br>Factor of "0.2" | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 43: | Line 51: | ||
− | ===[[image:Check.jpg|25px]] ENHANCED: | + | ===[[image:Check.jpg|25px]] ENHANCED: Default Parts Folder Changed=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400> | <td width=400> | ||
− | TubeCAD was changed to | + | TubeCAD's default part folder was changed to depend on the user logged in in Windows (See the next enhancement for details how we now handle paths).<br><br> |
− | + | The path will be the "tcadpro" folder inside the "My Documents" folder. All data types are stored in this folder from this version on.<br><br> | |
+ | (Note: This folder will be unique for each user login.) | ||
+ | </td> | ||
<td width=300> | <td width=300> | ||
+ | [[image:tcadpro_mydocuments.jpg|300px]] | ||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | ===[[image:Check.jpg|25px]] | + | ===[[image:Check.jpg|25px]] ENHANCED: Changes for Multi-User Login and UAC Restrictions=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
+ | <td width=400> | ||
+ | TubeCAD was changed to install once in administrative mode, and then run with any new user login in Windows using the Microsoft data storage methods.<br><br> | ||
+ | * For IT departments: See [[How TubeCAD Handles Data Storage for Multiple User Logins]] for details.</td> | ||
<td width=300> | <td width=300> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | |||
+ | |||
==Other Pages== | ==Other Pages== | ||
*Back to the [[TubeCAD Pro]] page | *Back to the [[TubeCAD Pro]] page |
Latest revision as of 19:41, 6 March 2013
Version 8-20130304Back to TubeCAD Pro |
Contents |
NEW - Excel Import and Export
TubeCAD has a new XLS command that allows you to import or export XLS files that contain XYZ centerline data. |
NEW: Command "PointLabelSpacing" controls point LABEL offset
ENHANCED: Default Parts Folder Changed
TubeCAD's default part folder was changed to depend on the user logged in in Windows (See the next enhancement for details how we now handle paths). |
ENHANCED: Changes for Multi-User Login and UAC Restrictions
TubeCAD was changed to install once in administrative mode, and then run with any new user login in Windows using the Microsoft data storage methods.
|
Other Pages
- Back to the TubeCAD Pro page