Difference between revisions of "VTube-LASER v1.86"

From ATTWiki
Jump to: navigation, search
(25px ENHANCED: Measure Process Menu Reorganized)
(25px ENHANCED: Measure Process Menu Reorganized)
Line 54: Line 54:
 
<td width=300>
 
<td width=300>
 
[[image:vtube-laser-1.86_measureprocessmenu.png|400px]]<br><br>
 
[[image:vtube-laser-1.86_measureprocessmenu.png|400px]]<br><br>
 +
 +
</td>
 +
</tr>
 +
</table>
 +
 +
<br><br>
 +
 +
 +
===[[image:Check.jpg|25px]] ENHANCED: Straight Count Control Moved to Setup Menus===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=400>
 +
 +
Sometimes the workflow to set the straight count for measuring was confusing, so now these controls were moved out of this menu and into separate windows that appear after operators press the scan buttons.  They appear like this:<br><br>
 +
 +
</td>
 +
<td width=300>
 +
[[image:vtube-laser-1.86_setuptubecylindermeasure.png|400px]]<br><br>
  
 
</td>
 
</td>

Revision as of 15:39, 20 January 2014

Vtube-laser logo.jpg

Revision 1.86


Vtube-laser 1.81.4.jpg

Contents




Check.jpg ENHANCED: Bender Number Stored in Project

Vtube-laser 1.86 BenderNumber.png

The bender number selected for communications is now stored in the project file for recall later. The assumption is that a given part is often bent on the same bender.




Check.jpg ENHANCED: Measure Process Menu Reorganized

To help ease the workflow in VTube-LASER, the Measure Tube-Cylinder panel is moved to the top of the Measure Process menu.

Also, the STRAIGHT COUNT controls were moved out of this menu. These controls are in separate windows that appear after operators press the scan buttons. They appear like this:

Vtube-laser-1.86 setuptubecylindermeasure.png

Vtube-laser-1.86 measureprocessmenu.png




Check.jpg ENHANCED: Straight Count Control Moved to Setup Menus

Sometimes the workflow to set the straight count for measuring was confusing, so now these controls were moved out of this menu and into separate windows that appear after operators press the scan buttons. They appear like this:

Vtube-laser-1.86 setuptubecylindermeasure.png



Check.jpg ENHANCED: AddisonMckee Mark IV EXTENDED Communications

AddisonMckeeMarkIV.png

Some AddisonMckee Mark IV benders require that its custom teach mode data be returned in the communication data during an automated bender correction from VTube. For benders that require this data during corrections from VTube, if this data is not found by the control, then a small message box will appear with a message that the incoming data is not AddisonMckee Mark IV data, and the correction data will be ignored.

To solve this problem, VTube-LASER now takes in and stores this data during a RECALL from the bender. When VTube sends corrections back to the bender, it includes this custom data in the transmission. This means that a RECALL is required before corrections are made to this kind of control.

  • If the Mark IV data is available, then a new tab menu appears next to the correction grid in Bender Data Setup.

  • This tab menu shows the AddisonMckee custom data. It can be read but not modified.

  • Be sure to perform a RECALL from the AddisonMckee before attempting to SEND corrections. This will ensure that this data is stored and returned to the bender at correction time.



AddisonMckeeMarkIVExtendedData.png



Check.jpg Other Changes

  • More optimizations were performed on internal timers - making VTube faster.

  • Changes were made to the interface to clear up the potential for orphaned windows in Dell M6700 laptops. For example, when the LASER mode window displays, the STEP mode window is now made invisible.

  • VTube-LASER Bender Data Setup is quicker to return an error message when it any network connection no longer exists. Previous versions could lock for minutes.

  • The "Cancel Changes" button now works inside the Comment editors.

  • The VTube splash screen now loads and displays before VTube starts loading.



Other