Difference between revisions of "VTube-LASER v1.86"
(→25px ENHANCED: Measure Process Menu Reorganized) |
|||
(20 intermediate revisions by one user not shown) | |||
Line 40: | Line 40: | ||
<br><br> | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Project Open and Save Path is Stored=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | |||
+ | The most recently used project file open and save paths are now stored and used for future open and saves. | ||
+ | <br><br> | ||
+ | [[image:vtube-1.86-opendialog.png|500px]]<br><br> | ||
+ | |||
+ | </td> | ||
+ | <td width=300> | ||
+ | |||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
===[[image:Check.jpg|25px]] ENHANCED: Measure Process Menu Reorganized=== | ===[[image:Check.jpg|25px]] ENHANCED: Measure Process Menu Reorganized=== | ||
Line 48: | Line 66: | ||
To help ease the workflow in VTube-LASER, the Measure Tube-Cylinder panel is moved to the top of the Measure Process menu. | To help ease the workflow in VTube-LASER, the Measure Tube-Cylinder panel is moved to the top of the Measure Process menu. | ||
<br><br> | <br><br> | ||
− | + | [[image:vtube-laser-1.86_measureprocessmenu.png|400px]]<br><br> | |
− | [[image:vtube-laser-1. | + | |
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | + | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: Straight Count Controls Moved to Setup Menus=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | |||
+ | Sometimes the workflow to set the straight count before measuring was confusing, so now these controls are moved out of this menu and into separate windows that appear after operators press the scan buttons. They appear like this:<br><br> | ||
+ | [[image:vtube-laser-1.86_setuptubecylindermeasure.png|400px]]<br><br> | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-laser-1.86-userinterface.png|400px]]<br><br> | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 83: | Line 116: | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Other Bender Data Setup Menu Changes=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | |||
+ | * A new CLEAR the Adjustment is added to allow operators to clear the Adjustment Grid.<br><br> | ||
+ | * A new CLEAR the AddisonMckee Mark IV enhanced data button is added.<br><br> | ||
+ | [[image:vtube-laser-1.86-clearbuttons.png|400px]]<br><br> | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-laser-1.86-clearadjustmentbutton.png|600px]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | * The AUTO SEND buttons now send the the MASTER XYZ with the BLUE COLUMN LRA data automatically.<br><br> | ||
+ | [[image:vtube-laser-1.86-autosendbuttons.png|400px]]<br><br> | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
<br><br> | <br><br> | ||
Line 93: | Line 155: | ||
* Changes were made to the interface to clear up the potential for orphaned windows in Dell M6700 laptops. For example, when the LASER mode window displays, the STEP mode window is now made invisible.<br><br> | * Changes were made to the interface to clear up the potential for orphaned windows in Dell M6700 laptops. For example, when the LASER mode window displays, the STEP mode window is now made invisible.<br><br> | ||
* VTube-LASER Bender Data Setup is quicker to return an error message when it any network connection no longer exists. Previous versions could lock for minutes.<br><br> | * VTube-LASER Bender Data Setup is quicker to return an error message when it any network connection no longer exists. Previous versions could lock for minutes.<br><br> | ||
− | * The "Cancel Changes" button now works inside the Comment editors.<br><br> | + | * COMMENT Editor Window: The "Cancel Changes" button now works inside the Comment editors.<br><br> |
* The VTube splash screen now loads and displays before VTube starts loading.<br><br> | * The VTube splash screen now loads and displays before VTube starts loading.<br><br> | ||
Latest revision as of 17:03, 24 February 2014
Revision 1.86
|
- See VTube-LASER Customer Support Page to download the latest version.
ENHANCED: Bender Number Stored in Project
The bender number selected for communications is now stored in the project file for recall later. The assumption is that a given part is often bent on the same bender.
|
NEW: Project Open and Save Path is Stored
The most recently used project file open and save paths are now stored and used for future open and saves.
|
ENHANCED: Measure Process Menu Reorganized
To help ease the workflow in VTube-LASER, the Measure Tube-Cylinder panel is moved to the top of the Measure Process menu.
|
|
ENHANCED: Straight Count Controls Moved to Setup Menus
ENHANCED: AddisonMckee Mark IV EXTENDED Communications
Some AddisonMckee Mark IV benders require that its custom teach mode data be returned in the communication data during an automated bender correction from VTube. For benders that require this data during corrections from VTube, if this data is not found by the control, then a small message box will appear with a message that the incoming data is not AddisonMckee Mark IV data, and the correction data will be ignored. To solve this problem, VTube-LASER now takes in and stores this data during a RECALL from the bender. When VTube sends corrections back to the bender, it includes this custom data in the transmission. This means that a RECALL is required before corrections are made to this kind of control.
|
NEW: Other Bender Data Setup Menu Changes
|
|
Other Changes
|
Other
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER
- See VTube Language Editor