Difference between revisions of "VTube-LASER v1.88"
(→25px ENHANCEMENT and FIX: VTube Ball Probe Logic for Newer FARO Drivers) |
(→25px NEW: Project Open QuickLoad Window) |
||
Line 35: | Line 35: | ||
</table> | </table> | ||
− | ===[[image:Check.jpg|25px]] | + | ===[[image:Check.jpg|25px]] ENHANCEMENT: UniScan Ball Probe Measurements=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400> | <td width=400> | ||
− | + | The math logic used to separate the UniScan ball probe measurements is changed and improved.<br><br> | |
− | <br><br> | + | In this version, VTube-LASER will now assume that the last three points of a straight cylinder surface will be the furthest three points from the first points taken on the cylinder.<br><br> |
− | + | Follow these simple steps to use this new method:<br><br> | |
+ | |||
+ | 1 - Take three points at the starting end of the straight.<br> | ||
+ | 2 - Take three points at the other end of the straight.<br> | ||
+ | 3 - Press the red button.<br><br> | ||
+ | |||
+ | In UniScan mode, you can take as many points as you would like in between the two sets of three points.<br><br> | ||
+ | |||
+ | The minimum number of points in UniScan is 6. | ||
+ | |||
+ | |||
+ | |||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | |||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | + | <br> | |
===[[image:Check.jpg|25px]] NEW: Cylinder Laser Spike Filter=== | ===[[image:Check.jpg|25px]] NEW: Cylinder Laser Spike Filter=== |
Revision as of 20:33, 11 March 2014
Revision 1.88
|
- See VTube-LASER Customer Support Page to download the latest version.
ENHANCEMENT and FIX: VTube Ball Probe Logic for Newer FARO Drivers
In November of 2013, FARO drivers were updated to work with the new FARO Edge ES scanner. This new driver made changes to the way ball probe data was returned to VTube-LASER. Sometimes ball probe data would be returned as all zeros. At other times, it could be returned as data that was scanned in previous measures. |
]
|
ENHANCEMENT: UniScan Ball Probe Measurements
The math logic used to separate the UniScan ball probe measurements is changed and improved. 1 - Take three points at the starting end of the straight. In UniScan mode, you can take as many points as you would like in between the two sets of three points. The minimum number of points in UniScan is 6.
|
NEW: Cylinder Laser Spike Filter
NEW: Automatic Remeasure At Measure Error
ENHANCED: Added Radius Handling for Winton ECNC4 Benders
The Winton ECNC4 data now handles the radius value during communications.
|
Other Changes
|
Other
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER
- See VTube Language Editor