The automatic end weighting Best Fit alignment method is significantly improved:<br><br> | The automatic end weighting Best Fit alignment method is significantly improved:<br><br> | ||
* Each iteration of the deviations are shown in real time in the Inspection Data menu. Watch the grids change rapidly as the engine tries new alignments.<br><br> | * Each iteration of the deviations are shown in real time in the Inspection Data menu. Watch the grids change rapidly as the engine tries new alignments.<br><br> | ||
− | * The progress window shows more information - like the goal precision level the engine is seeking for. For example, if the Automatic | + | * The progress window shows more information - like the goal precision level the engine is seeking for. For example, if the Automatic Alignment Stop value is 0.5 and the tolerance is 0.039, then the progress window will show a goal precision of "0.019". The goal precision is used in decision making during automatic alignments. If all tangent deviations are equal to or less than the goal precision, then alignment stops immediately. This makes automatic alignment much faster potentially.<br><br> |
* The Automatic Alignment Stop value is renamed to make it more understandable: "Automatic Alignment Stop at Deviation Multiplied Against..." is the new name. | * The Automatic Alignment Stop value is renamed to make it more understandable: "Automatic Alignment Stop at Deviation Multiplied Against..." is the new name. | ||
Revision as of 15:45, 28 June 2014
Revision 1.91
|
- See VTube-LASER Customer Support Page to download the latest version.
NEW: Use Leapfrog To Measure Tubes Longer Than the Arm's Reach
NEW: Redesign for XYZ INTERSECTION Inspection Values
The data shown on the right is from the new Expanded Grid (see "Expanded Grid" section below). |
NEW: Redesign for XYZ TANGENT Inspection Values
The data shown on the right is from the new Expanded Grid (see "Expanded Grid" section below). |
NEW: Expanded Grid Window for Inspection Data, Send to MS Office
The XYZ Intersection deviation and the XYZ Tangent point deviation values can now be displayed in the Expanded Grid window.
|
NEW: XYZ Intersection +/- Tolerance Values in Printed Reports
The new XYZ Intersection deviation values are included in reports:
|
ENHANCED and NEW: Alignment Feature Changes
FEATURE 1 - ALIGNMENT ENGINE: Fixes and Significantly More Powerful
The automatic end weighting Best Fit alignment method is significantly improved:
|
FEATURE 2 - MEASURE COMPLETE WINDOW: Measurement Complete Dialog REDESIGNED with Alignment Choices
This new measurement complete dialog gives you more choices than before. It no longer assumes that you want to use the current default alignment method. |
FEATURE 2 - INSPECTION DATA MENU: Alignment Button Displays Alignment Method Selected
The Inspection Data recalculate alignment button now displays the currently selected alignment method. This fixes a problem where users had to guess the alignment method when recalculating the measured to master alignment. |
NEW: Direct Communications with Eaton Leonard Premier, EL2000, and Ve-log Benders
|
Enhanced: Project Batch Report Output
Other Changes
|
Other