Difference between revisions of "VTube-STEP v1.93"

From ATTWiki
Jump to: navigation, search
(Created page with "<table> <tr cellpadding=10> <td width=225> 300px ==Revision 1.93== * Back to VTube-STEP * Back to VTube-STEP Revisions * Back to VTube ...")
 
(25px NEW: Added the End A and End B Diameter Values in STEP Mode Part Setup)
 
(22 intermediate revisions by one user not shown)
Line 10: Line 10:
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-step-1.92_screenshot.png|300px]]
+
[[image:vtube-step-1.93_screenshot.png|300px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 19: Line 19:
 
<br>
 
<br>
  
===[[image:Check.jpg|25px]] NEW: End A / End B Diameter Values in STEP Part Setup  ===
+
===[[image:Check.jpg|25px]] NEW: Import CSM M3 Bender Files===
 +
[[image:vtube-step-1.93_csm_m3_import_button.png]]
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
<td width=400>
+
<td width=300>
 +
VTube-STEP can now import CSM M3 bender files.<br><br>
 +
* Import the centerline XYZ data.
 +
* Or import the YBC data.<br><br>
 +
[[image:vtube-step-1.93_csm_m3_import_radiobuttons.png]]<br><br>
 +
* Other values imported are:
 +
** Diameter
 +
** Wall Thickness
 +
** Pre Length (Start Length)
 +
** End Length
 +
** Cut Length
 +
** Pipe Material Note
 +
</td>
 +
<td width=500>
 +
[[image:vtube-step-1.93_csm_m3_importfeature.png|400px]]
 +
</td>
 +
</tr>
 +
</table>
 +
 
 +
===[[image:Check.jpg|25px]] NEW: Added the End A and End B Diameter Values in STEP Mode Part Setup  ===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 
The End A and End B diameters were only in VTube-LASER.  Now they are in VTube-STEP in order to allow users to control the data when outputting data to a Supravision file in VTube-STEP.<br><br>
 
The End A and End B diameters were only in VTube-LASER.  Now they are in VTube-STEP in order to allow users to control the data when outputting data to a Supravision file in VTube-STEP.<br><br>
 
The two values are placed immediately after the Diameter field.
 
The two values are placed immediately after the Diameter field.
 
</td>
 
</td>
 
<td width=500>
 
<td width=500>
 +
[[image:vtube-1.93_EndDiameters.png|400px]]
 
</td>
 
</td>
 +
</tr>
 +
</table>
 +
 +
 +
===[[image:Check.jpg|25px]] NEW: Added the Default Tolerance Value in Part Setup  ===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 +
Some output formats prefer to have a default tolerance built into the export, so now the Default Tolerance value is included in the VTube-STEP Part Setup menu.<br><br>
 +
</td>
 +
<td width=500>
 +
[[image:vtube-1.93_DefaultTolerance_PartSetup.png|400px]]
 +
</td>
 +
</tr>
 +
</table>
 +
 +
===[[image:Check.jpg|25px]] NEW: Automatic Set of End Diameters When Calculating Centerlines  ===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 +
The end diameters are now set to equal the main diameter during centerline calculation from models.
 +
</td>
 +
<td width=500>
 +
[[image:vtube-1.93_EndDiameters_Model.png|400px]]
 +
</td>
 +
</tr>
 +
</table>
 +
 +
===[[image:Check.jpg|25px]] NEW: Added to the Popup Menu to Synchronize End Diameters with Main Diameter  ===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 +
The pop up menus for the Part Setup menu (STEP and LASER modes) now allow for the end diameters to be synchronized with the main diameter.<br><br>
 +
</td>
 +
<td width=400>
 +
[[image:vtube-1.93_SyncEndDiametersPopup.png|400px]]<br><br>
 +
[[image:vtube-1.93_EndDiametersAfter.png|400px]]
 +
</td>
 +
</tr>
 +
</table>
 +
 +
===[[image:Check.jpg|25px]] ENHANCED: Fine-Tune Export to Laservision Spreadsheet Format Files ===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 +
The Eaton Leonard Laservision measuring center can import CSV (Comma Separated Value) files built in an Excel spreadsheet.  This version of VTube can now export to this format.  This version fine-tunes the new feature to make the output conform to customer specifications for the project.<br><br>
 +
</td>
 +
<td width=500>
 +
[[image:vtube-step-1.93_export_laservision.png|400px]]<br><br></td>
 +
</tr>
 +
</table>
 +
 +
 +
===[[image:Check.jpg|25px]] NEW: Previous Paths List in Quick Open ===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 +
The Quick Open dialog now has a pull-down list that shows all the recent previous paths used to load VTube project files or imported solid model files.<br><br>
 +
Click on the previous path to use, and the folder tree on the left will open the new folder.
 +
</td>
 +
<td width=500>
 +
[[image:vtube-1.93_PreviousPaths.png|400px]]<br><br></td>
 
</tr>
 
</tr>
 
</table>
 
</table>
Line 35: Line 121:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
 +
 +
* Updated the Chinese translation.
 +
* Updated the German translation.
  
  

Latest revision as of 17:52, 23 July 2014

Vtube-step logo.jpg

Revision 1.93

Vtube-step-1.93 screenshot.png



Check.jpg NEW: Import CSM M3 Bender Files

Vtube-step-1.93 csm m3 import button.png

VTube-STEP can now import CSM M3 bender files.

  • Import the centerline XYZ data.
  • Or import the YBC data.

Vtube-step-1.93 csm m3 import radiobuttons.png

  • Other values imported are:
    • Diameter
    • Wall Thickness
    • Pre Length (Start Length)
    • End Length
    • Cut Length
    • Pipe Material Note

Vtube-step-1.93 csm m3 importfeature.png

Check.jpg NEW: Added the End A and End B Diameter Values in STEP Mode Part Setup

The End A and End B diameters were only in VTube-LASER. Now they are in VTube-STEP in order to allow users to control the data when outputting data to a Supravision file in VTube-STEP.

The two values are placed immediately after the Diameter field.

Vtube-1.93 EndDiameters.png


Check.jpg NEW: Added the Default Tolerance Value in Part Setup

Some output formats prefer to have a default tolerance built into the export, so now the Default Tolerance value is included in the VTube-STEP Part Setup menu.

Vtube-1.93 DefaultTolerance PartSetup.png

Check.jpg NEW: Automatic Set of End Diameters When Calculating Centerlines

The end diameters are now set to equal the main diameter during centerline calculation from models.

Vtube-1.93 EndDiameters Model.png

Check.jpg NEW: Added to the Popup Menu to Synchronize End Diameters with Main Diameter

The pop up menus for the Part Setup menu (STEP and LASER modes) now allow for the end diameters to be synchronized with the main diameter.

Vtube-1.93 SyncEndDiametersPopup.png

Vtube-1.93 EndDiametersAfter.png

Check.jpg ENHANCED: Fine-Tune Export to Laservision Spreadsheet Format Files

The Eaton Leonard Laservision measuring center can import CSV (Comma Separated Value) files built in an Excel spreadsheet. This version of VTube can now export to this format. This version fine-tunes the new feature to make the output conform to customer specifications for the project.

Vtube-step-1.93 export laservision.png


Check.jpg NEW: Previous Paths List in Quick Open

The Quick Open dialog now has a pull-down list that shows all the recent previous paths used to load VTube project files or imported solid model files.

Click on the previous path to use, and the folder tree on the left will open the new folder.

Vtube-1.93 PreviousPaths.png

Check.jpg Other Changes

  • Updated the Chinese translation.
  • Updated the German translation.


Other Pages