Difference between revisions of "VTube-LASER v1.93"
From ATTWiki
(→25px NEW: Import CSM M3 Bender Files (VTube-STEP Mode)) |
(→25px NEW: Added to the Popup Menu to Synchronize End Diameters with Main Diameter) |
||
(5 intermediate revisions by one user not shown) | |||
Line 31: | Line 31: | ||
* Import the centerline XYZ data. | * Import the centerline XYZ data. | ||
* Or import the YBC data.<br><br> | * Or import the YBC data.<br><br> | ||
− | [[image:vtube-step-1.93_csm_m3_import_radiobuttons.png]]<br><br> | + | [[image:vtube-step-1.93_csm_m3_import_radiobuttons.png|300px]]<br><br> |
* Other values imported are: | * Other values imported are: | ||
** Diameter | ** Diameter | ||
Line 45: | Line 45: | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
===[[image:Check.jpg|25px]] NEW: Added the Default Tolerance Value in Part Setup === | ===[[image:Check.jpg|25px]] NEW: Added the Default Tolerance Value in Part Setup === | ||
Line 51: | Line 50: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | Some output formats prefer to have a default tolerance built into the export, so now the Default Tolerance value is included in the VTube- | + | Some output formats prefer to have a default tolerance built into the export, so now the Default Tolerance value is included in the VTube-LASER Part Setup menu.<br><br> |
</td> | </td> | ||
<td width=500> | <td width=500> | ||
[[image:vtube-1.93_DefaultTolerance_PartSetup.png|400px]] | [[image:vtube-1.93_DefaultTolerance_PartSetup.png|400px]] | ||
</td> | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Added to the Popup Menu to Synchronize End Diameters with Main Diameter === | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | The pop up menus for the Part Setup menu (STEP and LASER modes) now allow for the end diameters to be synchronized with the main diameter.<br><br> | ||
+ | </td> | ||
+ | <td width=400> | ||
+ | [[image:vtube-1.93_SyncEndDiametersPopup.png|400px]]<br><br> | ||
+ | [[image:vtube-1.93_EndDiametersAfter.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Previous Paths List in Quick Open === | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | The Quick Open dialog now has a pull-down list that shows all the recent previous paths used to load VTube project files or imported solid model files.<br><br> | ||
+ | Click on the previous path to use, and the folder tree on the left will open the new folder. | ||
+ | </td> | ||
+ | <td width=500> | ||
+ | [[image:vtube-1.93_PreviousPaths.png|400px]]<br><br></td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
Line 63: | Line 87: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400> | <td width=400> | ||
− | * | + | |
+ | * Updated the Chinese translation. | ||
+ | * Updated the German translation. | ||
+ | |||
+ | |||
</td> | </td> | ||
<td width=300> | <td width=300> |
Latest revision as of 18:05, 23 July 2014
Revision 1.93
|
- See VTube-LASER Customer Support Page to download the latest version.
NEW: Import CSM M3 Bender Files (VTube-STEP Mode)
(The VTube-STEP mode is included with VTube-LASER.) VTube-STEP can now import CSM M3 bender files.
|
NEW: Added the Default Tolerance Value in Part Setup
Some output formats prefer to have a default tolerance built into the export, so now the Default Tolerance value is included in the VTube-LASER Part Setup menu. |
NEW: Added to the Popup Menu to Synchronize End Diameters with Main Diameter
The pop up menus for the Part Setup menu (STEP and LASER modes) now allow for the end diameters to be synchronized with the main diameter. |
NEW: Previous Paths List in Quick Open
Other Changes
|
Other
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER
- See VTube Language Editor