Difference between revisions of "VTube Communication with YLM Benders"
(→Follow these steps at the YLM CONTROL to import the measured data from VTube-LASER) |
(→Follow these steps at VTube-LASER to Correct a YLM Bender) |
||
Line 40: | Line 40: | ||
==[[VTube-LASER]] Correction Steps for YLM Benders== | ==[[VTube-LASER]] Correction Steps for YLM Benders== | ||
− | |||
<table> | <table> | ||
<tr valign=top> | <tr valign=top> | ||
Line 50: | Line 49: | ||
* Second, the YLM sends the correction the wrong way when taking in the MEASURED data and comparing it to its MASTER or NOMINAL data. The only way overcome this is to use a special INVERSION checkbox in the Supravision Export menu. Only use this inversion switch when sending measured data for correction.<br><br> | * Second, the YLM sends the correction the wrong way when taking in the MEASURED data and comparing it to its MASTER or NOMINAL data. The only way overcome this is to use a special INVERSION checkbox in the Supravision Export menu. Only use this inversion switch when sending measured data for correction.<br><br> | ||
+ | </td> | ||
+ | <td width=400> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | ===Follow these steps at VTube-LASER to Correct a YLM Bender=== | ||
+ | <table> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | STEP 1<br> | ||
+ | Switch to the MEASURED TUBE window and press the FILE tab.<br><br> | ||
+ | STEP 2<br> | ||
+ | Check the inversion box. The inversion box will only display if VTube knows you are saving MEASURED data to a Supravision file.<br><br> | ||
+ | STEP 3<br> | ||
+ | Save the Supravision file.<br><br> | ||
+ | STEP 4<br> | ||
+ | Move to the YLM control and follow the steps below to import the correction. | ||
</td> | </td> | ||
<td width=400> | <td width=400> |
Revision as of 01:47, 24 September 2014
|
Contents[hide] |
YLM Control software
The YLM Windows software allows for complete programming of bender setup. It includes a bender simulator. |
VTube-STEP and VTube-LASER Support for YLM Benders
VTube-STEP can export Supravision data to YLM benders. |
VTube-LASER Correction Steps for YLM Benders
The connection the bender is made with standard network connection, and a shared folder location between the VTube computer and the operator station computer.
|
Follow these steps at VTube-LASER to Correct a YLM Bender
STEP 1 |
Follow these steps at the YLM CONTROL to import the measured data from VTube-LASER
STEP 1 |
Other Pages
- See VTube-LASER
- See VTube-STEP