Difference between revisions of "VTube-LASER v1.99"
(→25px ENHANCEMENT: "Pull Arm from Cradle" Message REMOVED for Automatic Scan Modes) |
(→25px NEW: Alpine M4 Bender Correction) |
||
(3 intermediate revisions by one user not shown) | |||
Line 20: | Line 20: | ||
− | ===[[image:Check.jpg|25px]] | + | ===[[image:Check.jpg|25px]] NEW: Alpine M4 Bender Correction=== |
<table cellpadding=10 width=800> | <table cellpadding=10 width=800> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | The | + | The Alpine M4 bender format was added to VTube-LASER.<br><br> |
− | + | This allows VTube-LASER to correct the control in a full bi-directional corrections loop.<br><br> | |
− | + | This new feature also stores all the YBC data in the M4 format '''inside the VTube project files''' - which means the bender setup is stored along with the project and recalled when the project is loaded back into VTube. | |
</td> | </td> | ||
<td width=500> | <td width=500> | ||
− | [[image: | + | [[image:VTube-LASER-1.99_AlpineM4BenderCorrection.png|500px]] |
</td> | </td> | ||
</tr> | </tr> | ||
Line 36: | Line 36: | ||
− | ===[[image:Check.jpg|25px]] | + | ===[[image:Check.jpg|25px]] NEW: CSM M4 Bender Correction=== |
<table cellpadding=10 width=800> | <table cellpadding=10 width=800> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | This | + | The CSM M4 format was added to VTube-LASER.<br><br> |
− | + | This allows VTube-LASER to correct the control in a full bi-directional corrections loop.<br><br> | |
+ | This new feature also stores all the YBC data in the M4 format '''inside the VTube project files''' - which means the bender setup is stored along with the project and recalled when the project is loaded back into VTube. | ||
</td> | </td> | ||
<td width=500> | <td width=500> | ||
− | [[image:VTube | + | [[image:VTube-LASER-1.99_CSMM4BenderCorrection.png|500px]] |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | ===[[image:Check.jpg|25px]] ENHANCEMENT: Arm | + | ===[[image:Check.jpg|25px]] ENHANCEMENT: "Pull Arm from Cradle" Message REMOVED for Automatic Scan Modes=== |
<table cellpadding=10 width=800> | <table cellpadding=10 width=800> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | + | The message is of no value when the arm is running in automatic scan mode. It should only display when the scan algorithm is set to FIXED. This saves confusion for arm users that always use AUTOMATIC modes.<br><br> | |
+ | So now VTube only displays the message if the scanner is setup in the VTube Project file for FIXED mode. | ||
</td> | </td> | ||
<td width=500> | <td width=500> | ||
− | [[image:vtube-laser-1. | + | [[image:vtube-laser-1.99_armcradle_message.png|400px]] |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | ===[[image:Check.jpg|25px]] | + | |
+ | ===[[image:Check.jpg|25px]] ENHANCEMENT: Additional Setup Button Added for Winton WMC in Bender Setup=== | ||
<table cellpadding=10 width=800> | <table cellpadding=10 width=800> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | + | This new button allows users to modify the bender setup file before sending data to the bender.<br><br> | |
− | This allows | + | |
− | + | ||
</td> | </td> | ||
<td width=500> | <td width=500> | ||
− | [[image:VTube-LASER-1. | + | [[image:VTube--LASER-1.99_WMC_BenderSetup_AdditionalSetupButton.png|400px]] |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | + | ===[[image:Check.jpg|25px]] ENHANCEMENT: Arm Connected LED Lamp Added to Arm Utilties=== | |
− | ===[[image:Check.jpg|25px]] | + | |
<table cellpadding=10 width=800> | <table cellpadding=10 width=800> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | + | This new LED indicates that the arm is connected to the Arm Utilities menu.<br><br> | |
− | This | + | |
− | + | ||
</td> | </td> | ||
<td width=500> | <td width=500> | ||
− | [[image: | + | [[image:vtube-laser-1.99_LED_lamp_Arm_Setup.png|400px]] |
</td> | </td> | ||
</tr> | </tr> |
Latest revision as of 01:34, 26 November 2014
Revision 1.99
|
NEW: Alpine M4 Bender Correction
The Alpine M4 bender format was added to VTube-LASER. |
NEW: CSM M4 Bender Correction
The CSM M4 format was added to VTube-LASER. |
ENHANCEMENT: "Pull Arm from Cradle" Message REMOVED for Automatic Scan Modes
The message is of no value when the arm is running in automatic scan mode. It should only display when the scan algorithm is set to FIXED. This saves confusion for arm users that always use AUTOMATIC modes. So now VTube only displays the message if the scanner is setup in the VTube Project file for FIXED mode. |
ENHANCEMENT: Additional Setup Button Added for Winton WMC in Bender Setup
This new button allows users to modify the bender setup file before sending data to the bender. |
ENHANCEMENT: Arm Connected LED Lamp Added to Arm Utilties
This new LED indicates that the arm is connected to the Arm Utilities menu. |
Other
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER
- See VTube Language Editor