Difference between revisions of "VTube-LASER v2"
From ATTWiki
(→25px NEW: Winton WMC Bender Data File Setup Window) |
(→25px ENHANCED: SUPRAVISION Network Engine Now Handles Benders with Inverted Rotations) |
||
(6 intermediate revisions by one user not shown) | |||
Line 18: | Line 18: | ||
__NOTOC__ | __NOTOC__ | ||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: VTube Path Manager - Saves Time By Storing Important Paths=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | This change to VTube is a huge time-saver. Customers that have tested this feature report that they are very happy it.<br><br> | ||
+ | The new Path Manager allows you to store and recall complex file paths from VTube without having to constantly drill down into folders and paths.<br><br> | ||
+ | The window displays when you open projects and perform imports. It also opens when you perform a Save As project. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-step-2_screenimage_closeup_2.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
Line 33: | Line 48: | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: SUPRAVISION Network Engine Now Handles Benders with Inverted Rotations=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | The Supravision network engine now allows for rotations to be inverted for benders that have rotations that move in the opposite direction to VTube.</td> | ||
+ | <td width=400> | ||
+ | [[image:vtube-2_cwrotation_svnetwork.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: CSM and ALPINE File Data Transfer Tested and Improved=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | * The CSM and Alpine conversions now correctly invert the rotation value in both M3 and M4 controls - since they move in the opposite direction from VTube rotations.<br><br> | ||
+ | * Other adjustments and fixes to the conversion were tested with both styles of bender controls.<br><br> | ||
+ | * When VTube sends corrections to the M4 controls, it now changes the adjustment values rather than the nominal values in the YBC page. | ||
+ | </td> | ||
+ | <td width=400> | ||
+ | [[image:alpinebender.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] Other Changes=== | ||
+ | * The VTube configuration file location was changed to the more standard '''"c:\ProgramData\VTube"''' location.<br><br> | ||
+ | * The installation performs a better job of setting up the configuration file location.<br><br> | ||
+ | * The Supravision network engine has been enhanced to handle data files that don't follow the Supravison spec perfectly.<br><br> | ||
+ | * We fixed a ball probe measurement issue where VTube would sometimes not always take in single points from the FARO driver. This issue created problems with measuring cut planes too. If you measured cut planes, and still couldn't get the cut plane to work properly, then it was probably due to this issue.<br><br><br> | ||
==Other== | ==Other== |
Latest revision as of 23:36, 16 February 2015
Revision 2.00
|
NEW: VTube Path Manager - Saves Time By Storing Important Paths
This change to VTube is a huge time-saver. Customers that have tested this feature report that they are very happy it. |
NEW: Winton WMC Bender Data File Setup Window
The new window allows VTube users to edit the data inside a Winton WMC file before exporting or adjusting a WMC file. |
NEW: SUPRAVISION Network Engine Now Handles Benders with Inverted Rotations
The Supravision network engine now allows for rotations to be inverted for benders that have rotations that move in the opposite direction to VTube. |
ENHANCED: CSM and ALPINE File Data Transfer Tested and Improved
|
Other Changes
- The VTube configuration file location was changed to the more standard "c:\ProgramData\VTube" location.
- The installation performs a better job of setting up the configuration file location.
- The Supravision network engine has been enhanced to handle data files that don't follow the Supravison spec perfectly.
- We fixed a ball probe measurement issue where VTube would sometimes not always take in single points from the FARO driver. This issue created problems with measuring cut planes too. If you measured cut planes, and still couldn't get the cut plane to work properly, then it was probably due to this issue.
Other
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER
- See VTube Language Editor