Difference between revisions of "End-Scan Using a Ball Probe"
(→How To Use This End-Scan End Wall Technique) |
(→Ensuring the Proper Ball Probe Offset Direction) |
||
(12 intermediate revisions by one user not shown) | |||
Line 12: | Line 12: | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | + | __TOC__ | |
− | === | + | ===About the Ball Probe End Scan Technique=== |
<table cellpadding=10> | <table cellpadding=10> | ||
Line 53: | Line 53: | ||
* Align the probe the end of the tube as shown in the diagram below - take two points per quadrant.<br><br> | * Align the probe the end of the tube as shown in the diagram below - take two points per quadrant.<br><br> | ||
* Press and release the green button for each measure.<br><br> | * Press and release the green button for each measure.<br><br> | ||
− | * It is not necessary to take all four quadrants | + | * It is not necessary to take all four quadrants.<br><br> |
*Press the RED button when you are finished collecting data.<br><br> | *Press the RED button when you are finished collecting data.<br><br> | ||
Line 64: | Line 64: | ||
− | ===How to Overcome Trouble End | + | ===Ensuring the Proper Ball Probe Offset Direction=== |
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | With ball-probe end measurements, the direction you begin your first and last straight section straight section scan is very important. It gives VTube the ball probe offset direction.<br><br> | ||
+ | |||
+ | Follow these rules to project the point in the proper direction along the centerline:<br><br> | ||
+ | |||
+ | * On the FIRST straight: The location of the first stripe must be as close as possible to the end - then scan away from the end. Do not allow any stripe to be closer to the end point than the first stripe. | ||
+ | <br> | ||
+ | * On the LAST straight: The location of the first stripe must be as far as possible from the end - then scan toward the end. Do not allow any stripe to be further from the end point than the first stripe. | ||
+ | |||
+ | </td> | ||
+ | <td width=300> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ===How to Overcome Trouble With End-Scans=== | ||
<table cellpadding=10> | <table cellpadding=10> | ||
Line 70: | Line 89: | ||
<td width=300> | <td width=300> | ||
* Check the A End diameter to be sure it is close to the actual diameter.<br><br> | * Check the A End diameter to be sure it is close to the actual diameter.<br><br> | ||
− | * Open the end-scan tolerance in the MEASURE 2 tab of the Systems Option menu. The default value is 0.039" or 1 mm. You can open this tolerance as high as you wish - for example you could set it to 0. | + | * Open the end-scan tolerance in the MEASURE 2 tab of the Systems Option menu. The default value is 0.039" or 1 mm. You can open this tolerance as high as you wish - for example you could set it to 0.750" (19mm) or higher and always get a qualified end. When you increase the tolerance, just take more care that you are collecting good end points.<br><br> |
* With tactile scans, it is possible to backup if you feel you have collected a bad point. Just press the button for "Red Button Removes Points" in the measure collection window, and press the red button. Then toggle the switch off to continue measuring. | * With tactile scans, it is possible to backup if you feel you have collected a bad point. Just press the button for "Red Button Removes Points" in the measure collection window, and press the red button. Then toggle the switch off to continue measuring. | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | [[image: | + | [[image:EndScan_Tolerance.jpg|300px]] |
</td> | </td> | ||
</tr> | </tr> |
Latest revision as of 18:38, 2 April 2015
How to perform end-scans with a ball probe.
|
Contents |
About the Ball Probe End Scan Technique
This end-scan method is useful for situations where the only option is a ball probe - or where the Laser cannot reach effectively - but a ball probe can.
|
Measure Setup - For Measure the End Wall
|
How To Use This End-Scan End Wall Technique
|
Ensuring the Proper Ball Probe Offset Direction
With ball-probe end measurements, the direction you begin your first and last straight section straight section scan is very important. It gives VTube the ball probe offset direction. Follow these rules to project the point in the proper direction along the centerline:
|
How to Overcome Trouble With End-Scans
|
Measure Setup - For Ends That Move Into A Surface
|
How To Use This End-Scan End-Into-Surface Technique
|
Other Pages
- See also End-Scan Using the End Wall
- See also End-Scan Using End Targets
- Back to VTube-LASER