Difference between revisions of "Data Conversion Rules for Benderlink for Chiyoda/KEINS"
From ATTWiki
(→To Send ADJUSTMENTS to a KEINS or Chiyoda Bender from the Measuring Center) |
(→To Send NEW data to a KEINS or Chiyoda Bender from the Measuring Center) |
||
Line 18: | Line 18: | ||
== To Send NEW data to a KEINS or Chiyoda Bender from the Measuring Center == | == To Send NEW data to a KEINS or Chiyoda Bender from the Measuring Center == | ||
− | # To send NEW data to a KEINS or Chiyoda bender from a measuring center through Benderlink, it is important to clear the FPB data to one bend and set all the FPB values to ZERO. This includes the adjustment values.<br><br> | + | # To send NEW data to a KEINS or Chiyoda bender from a measuring center through Benderlink, it is important to clear the FPB data '''IN THE BENDER CONTROL''' to one bend and set all the FPB values to ZERO. This includes the adjustment values.<br><br> |
− | # In this case, the number of bend rows will be increased to match the measuring center data.<br><br> | + | # In this case, when the data is sent from the measuring center, BENDERLINK will perform a GET to update its bender data from the bender, then see that the there is one bend row and all ZEROS in the FPB data for the bender, then interpret that to know to automatically increase the number of bend rows will be increased to match the measuring center data.<br><br> |
# All data will be replaced.<br><br> | # All data will be replaced.<br><br> | ||
Revision as of 19:54, 15 October 2015
Data Conversion RulesBack to Benderlink for Chiyoda |
To Send NEW data to a KEINS or Chiyoda Bender from the Measuring Center
- To send NEW data to a KEINS or Chiyoda bender from a measuring center through Benderlink, it is important to clear the FPB data IN THE BENDER CONTROL to one bend and set all the FPB values to ZERO. This includes the adjustment values.
- In this case, when the data is sent from the measuring center, BENDERLINK will perform a GET to update its bender data from the bender, then see that the there is one bend row and all ZEROS in the FPB data for the bender, then interpret that to know to automatically increase the number of bend rows will be increased to match the measuring center data.
- All data will be replaced.
To Send ADJUSTMENTS to a KEINS or Chiyoda Bender from the Measuring Center
- If there are non-ZERO values in any of the FPB cells, or there is more than one bend row, then Benderlink will always MERGE new data to the existing rows. This setup is appropriate for corrections loops.
- This means that no new rows will be created if the incoming data has more bends than the existing bend count.