Difference between revisions of "VTube-LASER to Eaton Leonard Premier Communications Tutorial"
(→The Premier VECTOR 1 Menu) |
(→The Premier VECTOR 1 Menu) |
||
Line 38: | Line 38: | ||
<tr> | <tr> | ||
<td width=400> | <td width=400> | ||
− | To put the Premier in communications mode, make the REQUEST TRANSFER box active like is shown here.<br><br> | + | To put the Premier in communications mode, make the REQUEST TRANSFER box active (green) like is shown here. The WAITING field will be highlighted.<br><br> |
− | Before you make that button active, check on the following settings | + | Before you make that button active, check on the following settings: |
− | '''CHECK 1''' The MODE in the upper left corner should read "EXTERNAL MODE". It is controlled by the yellow button on the bottom right side of the screen. This mode allows VTube-LASER to control the communications.<br><br> | + | '''CHECK 1 - MODE'''<br> |
− | '''CHECK 2''' The bender number in both this menu and the VTube-LASER Benderlink setup must agree. If they don't, then VTube and the PREMIER will at least issue warnings or dialogs.<br><br> | + | The MODE in the upper left corner should read "EXTERNAL MODE". It is controlled by the yellow button on the bottom right side of the screen. This mode allows VTube-LASER to control the communications.<br><br> |
− | '''CHECK 3''' If you plan on using the RECALL inside VTube-LASER, then it is important that the correct part number is loaded into memory. That part number should display in the Part Number field. If the part numbers don't match during a VTube-LASER RECALL, then the communications will fail. (VTube-LASER sends a 4 byte request, then the PREMIER returns a short 20 byte answer - which is not an entire part, and VTube will time-out.)<br><br> | + | '''CHECK 2 - BENDER NUMBER MATCHES'''<br> |
+ | The bender number in both this menu and the VTube-LASER Benderlink setup must agree. If they don't, then VTube and the PREMIER will at least issue warnings or dialogs.<br><br> | ||
+ | '''CHECK 3 - CORRECT PART NUMBER IS ON THE SCREEN'''<br> | ||
+ | If you plan on using the RECALL inside VTube-LASER, then it is important that the correct part number is loaded into memory. That part number should display in the Part Number field. If the part numbers don't match during a VTube-LASER RECALL, then the communications will fail. (VTube-LASER sends a 4 byte request, then the PREMIER returns a short 20 byte answer - which is not an entire part, and VTube will time-out.)<br><br> | ||
</td> | </td> | ||
<td> | <td> |
Revision as of 16:26, 29 January 2016
VTube-LASER uses the legacy Eaton Leonard Current Loop protocol to communicate with Premier controls. The protocol requires that an RS-232 signal be converted to Current Loop, then sent to the bender. |
How to Use Communication Between the Premier and VTube-LASER
Communications between VTube-LASER and the Premier is very easy to do because it's robust and also very intuitive.
The Premier VECTOR 1 Menu
All communications from the PREMIER control occurs in the VECTOR 1 screen shown here. |
To put the Premier in communications mode, make the REQUEST TRANSFER box active (green) like is shown here. The WAITING field will be highlighted. CHECK 1 - MODE |