Difference between revisions of "VTube-LASER to Eaton Leonard Premier Communications Tutorial"
(→Sending a NEW Part from VTube-LASER) |
(→Sending a NEW Part from VTube-LASER) |
||
Line 56: | Line 56: | ||
</table> | </table> | ||
− | === | + | ===SENDING from VTube-LASER to the PREMIER=== |
<table> | <table> | ||
Line 64: | Line 64: | ||
'''RULE - VTube-LASER Data OVERWRITES When SENDING to the PREMIER'''<br> | '''RULE - VTube-LASER Data OVERWRITES When SENDING to the PREMIER'''<br> | ||
When you SEND data from VTube-LASER that has a different part name or different YBC data, then whatever is sent OVERWRITES the data in the PREMIER.<br><br> | When you SEND data from VTube-LASER that has a different part name or different YBC data, then whatever is sent OVERWRITES the data in the PREMIER.<br><br> | ||
− | The PREMIER control just politely assumes that whatever data is incoming is the new correct data - and just allows it to overwrite the current data. | + | The PREMIER control just politely assumes that whatever data is incoming is the new correct data - and just allows it to overwrite the current data.<br><br> |
+ | '''NEW PART - KEEP THE CURRENT SETUP''' | ||
+ | When sending a new part, you might want to keep the current tool setup of the previous part as a starting place. Otherwise you will need to reset all the values before bending the first part. | ||
</td> | </td> | ||
<td> | <td> |
Revision as of 16:45, 29 January 2016
VTube-LASER uses the legacy Eaton Leonard Current Loop protocol to communicate with Premier controls. The protocol requires that an RS-232 signal be converted to Current Loop, then sent to the bender. |
Contents |
How to Use Communication Between the Premier and VTube-LASER
Communications between VTube-LASER and the Premier is very easy to do because it's robust and also very intuitive.
The Initial Premier VECTOR 1 Menu
All communications from the PREMIER control occurs in the VECTOR 1 screen shown here. |
Premier VECTOR 1 Menu With Communications Active
To put the Premier in communications mode, make the REQUEST TRANSFER box active (green) like is shown here. The WAITING field will be highlighted. CHECK 1 - CORRECT MODE IS ACTIVE |
SENDING from VTube-LASER to the PREMIER
SENDING data from VTube has slightly different rules than performing a RECALL. |
Other Pages
- Back to the Benderlink Ethernet Module Page
- Back to VTube-LASER