Difference between revisions of "How to Create Mirror Image Part"
(→How to Create a Mirror Image Part) |
(→STEP 1: Enter PART SETUP Data) |
||
Line 27: | Line 27: | ||
</table> | </table> | ||
− | ==STEP 1: | + | ==STEP 1: Additive Invert a Column in the XYZ Coordinates== |
<table cellpadding=10 width="900"> | <table cellpadding=10 width="900"> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400 > | <td width=400 > | ||
− | + | Select a cell in an XYZ column to invert, right click, the choose Additive Invert. | |
</td> | </td> | ||
<td width=400 > | <td width=400 > | ||
− | [[image:vtube-laser_v2. | + | [[image:vtube-laser_v2.2_steps_invert.png|500px]] |
</td> | </td> | ||
</tr> | </tr> |
Revision as of 02:00, 4 February 2016
|
How to Create a Mirror Image Part
To create a mirror image part, VTube lets you perform an Additive Invert on any column of XYZ values. This means that VTube can multiply an entire column of XYZ values negative one. |
STEP 1: Additive Invert a Column in the XYZ Coordinates
Select a cell in an XYZ column to invert, right click, the choose Additive Invert. |
STEP 2: Populate the MASTER TUBE DATA Grid
Since the Split Bend feature creates a grid based on the number of straights in the MASTER data, it is important to set the number of points that you will be measuring in the reversed tube. |
STEP 3: Configure the Split Bend Window
The Split Bend window is on the Bend Setup tab in the MASTER TUBE menu. Click into that window. |
|
In the Split Bend window, set any straight that will be treated as a Split Bend. |
STEP 4: Measure The Part
This step is identical to regular reverse-engineering measuring. |
STEP 5: Choose Build Measured Tube Data Only
Because the MASTER data row count is greater than zero, the Measurement Complete window will offer to allow you to ALIGN the measured tube. |
|
The new measured tube will appear as a blue tube like this. |
STEP 6: Copy Measured to Master
Copy Measured to Master Data in the Data Handling menu. This will overwrite the MASTER data ZEROS with the MEASURED tube data. |
STEP 7: Optional Reset Origin to Zero
Some customers prefer to translate the new MASTER data so that the first point is at 0,0,0. |
STEP 8: View the New Master Tube
View the new MASTER tube by switching the display of the Master tube on, then redrawing and zooming all. |
STEP 9: Optional Alignment Test
This is a cross-check to be sure the process was performed properly. Enter the Inspection Results menu, and press Recalculate for the alignment. |
STEP 10: Save the VTube Project
Press the Project Save button in the Toolbar, choose the project save path and filename, and save the VTube Project file. |
Other Pages
- Back to VTube-LASER
- See also Calibration-Leapfrog-Move Targets
- Purchase the targets at the store.