Difference between revisions of "VTube-LASER v2.3"
(→25px ENHANCEMENT: Communications Buttons Disable During Communications) |
(→25px NEW EXPERIMENTAL FEATURE: Scan to Point Cloud) |
||
(11 intermediate revisions by one user not shown) | |||
Line 180: | Line 180: | ||
<td width=300> | <td width=300> | ||
Previous versions of VTube-LASER would allow for an accidental multiple button presses in the middle of communications with a bender.<br><br> | Previous versions of VTube-LASER would allow for an accidental multiple button presses in the middle of communications with a bender.<br><br> | ||
− | This | + | This multiple-press during communications can cause the communication to fail.<br><br> |
This was changed so that buttons are disabled once communications begin, and then re-enable when communications are finished. | This was changed so that buttons are disabled once communications begin, and then re-enable when communications are finished. | ||
Line 192: | Line 192: | ||
+ | ==[[image:Check.jpg|25px]] NEW EXPERIMENTAL FEATURE: Scan to Point Cloud== | ||
+ | <table cellpadding=10 width=700> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | We are opening this experimental feature to our users. This Scan to Point Cloud feature is embedded in the Tube-Cylinder measurement feature.<br><br> | ||
+ | With this feature, you can scan any shape into a point cloud and then save it the file '''"C:\Users\Public\Documents\VTube\pointcloud.txt"'''.<br><br> | ||
+ | This file can be imported into solid modelling programs like SOLIDWORKS.<br><br> | ||
+ | The image on the right shows the scanning result of a mouse.<br><br> | ||
+ | To use this feature, you can use these setup values: | ||
+ | |||
+ | * Use the Cut Plane to filter out table points.<br><br> | ||
+ | * Set the Cylinder Stripes Per Measure to 2000. (It may be necessary to increase the Maximum Number of Stripes Per Straight Allowed in VTube System Options - Measure 2 tab.)<br><br> | ||
+ | * Set the Maximum Number of Points Allowed in Cylinder Stripes to 2000.<br><br> | ||
+ | * Set the Cylinder Scan Data Proximity Filter to 0.010 inches or higher. This will control how dense the point cloud saved is.<br><br> | ||
+ | * To start measuring, use UNISCAN Tube-Cylinder, then set the number of straights to 1. Take an end stripe anywhere, then start scanning the object. Then press Save Point Cloud to File. If the point cloud is very dense, then saving may take a few minutes.<br><br> | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-laser_v2.3_experimental_scanning_to_cloud.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | |||
+ | ==[[image:Check.jpg|25px]] NEW: Reset Point Labels in XYZ Data with Popup Menu== | ||
+ | <table cellpadding=10 width=700> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | This feature was available in VTube-STEP in previous versions, but has been added to VTube-LASER in this version.<br><br> | ||
+ | If you reverse the point order, then you will also reverse the point labels in the MASTER and MEASURED XYZ data.<br><br> | ||
+ | If you want them to be ordered from low to high after a reverse, then you can use this new popup menu feature do handle the reset.<br><br> | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-laser_v2.3_popup_pointreset.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
<br><br> | <br><br> |
Latest revision as of 21:10, 14 February 2016
Revision 2.3
|
This Update is Important For...
- Customers that use springback compensation of any form in VTube
- Customers that use tube elongation percentage to predict cut length and unbending lengths
- Customers that experienced image draw problems in the REPORT window
- Customers that communicate with benders in the Bender Setup page.
FIX: Tube Image Display and Refresh in the Report Window
|
NEW: Press Enter to Set Point Count
Users like to press the Enter key after entering the point count in the XYZ grids, so we've allowed for that action VTube. |
ENHANCED: Increase Maximum Point Limit from 102 up to 202 (200 Bends)
One customer had parts that required over 100 bends, so we increased the maximum number of bends allowed in VTube to 200. |
ENHANCEMENT: Blank White Cells Replace Dashes and Zeros
The grid interface is now cleaner than in previous versions. Previous versions would show zeros for the end point radii, and also dashes in LRA cells that are not used. |
FIX: Springback Compensation Issues Repaired
If you use springback compensation in VTube, then this upgrade is important for you. |
NEW: Springback-Compensated LRA Grids
NEW: Multi-Elongation Percentage Compensation Setup
ENHANCEMENT: Springback Compensation Calculation in the Outgoing Bender Data Is Now Optional
This feature adds springback compensation into the outgoing LRA data. In previous versions it was not optional. For some benders (for example, the Eaton Leonard Lightspeed) this addition is NOT recommended because this causes the springback to be added by both VTube and the bender. This doubles the compensation - which is incorrect. If you're not sure if you should use this option, then test how your bender uses the springback compensation values by entering non-zero Springback values in VTube's Part Setup menu, then send data with this feature activated. If the bend values display with the overbend doubled, then you know that the control handles the springback compensation automatically. |
ENHANCEMENT: Keep the Previous Custom Default Setup During Upgrades
If you've made changes to your default settings, you will want to skip installing a new set of configuration files. This version allows you to skip the installation of new configuration files with new choices in the installation file. In addition to updating the main program files, you can now also control installation of:
|
ENHANCEMENT: Communications Buttons Disable During Communications
Previous versions of VTube-LASER would allow for an accidental multiple button presses in the middle of communications with a bender. |
NEW EXPERIMENTAL FEATURE: Scan to Point Cloud
We are opening this experimental feature to our users. This Scan to Point Cloud feature is embedded in the Tube-Cylinder measurement feature.
|
NEW: Reset Point Labels in XYZ Data with Popup Menu
This feature was available in VTube-STEP in previous versions, but has been added to VTube-LASER in this version. |
Other
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER
- See VTube Language Editor