Difference between revisions of "VTube-LASER v2.5"
(→25px NEW MAJOR FEATURE: Bend Profile Out-of-round % Measurement) |
(→25px NEW MAJOR FEATURE: Bend Profile Out-of-round % Measurement) |
||
Line 23: | Line 23: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | + | '''This feature is unique to FARO systems using VTube-LASER'''.<br><br> | |
VTube-LASER can now measure '''bend profile regions''' in order to calculate the out-of-round percentage in multiple slice regions of any bend.<br><br> | VTube-LASER can now measure '''bend profile regions''' in order to calculate the out-of-round percentage in multiple slice regions of any bend.<br><br> |
Revision as of 14:02, 27 April 2016
Revision 2.5
|
NEW MAJOR FEATURE: Bend Profile Out-of-round % Measurement
This feature is unique to FARO systems using VTube-LASER. VTube-LASER can now measure bend profile regions in order to calculate the out-of-round percentage in multiple slice regions of any bend. This feature is only possible because the FARO ScanArm uses a surface scanner. Other measuring methods that do not scan surface points cannot perform this kind of measurement. |
IMPROVED: Best Fit - Automatic End Weight Version 2 - Tighter and Faster Alignments
We're always happy to give you a feature that does more - and does more FASTER than before. This is one of those features. The alignments shown on the right are the results of the two different kinds of alignments now available in version 2.5. We used the same master/measured data. When qualifications are on the edge of the tolerance, then the new version 2 of Best Fit has a better chance of qualifying a tube.
|
IMPROVED: The MEASUREMENT COMPLETE Window is Redesigned for Simplicity
The Measurement Complete window is the window that displays when you finish measurements. It has been redesigned to make it even easier to use. |
NEW: Project File Save Notification Proves the Project Was Saved
Previous versions of VTube were quiet when you saved a project file. That made some of our customers understandably nervous. |
NEW: HOT Keys Control-L (Load) and Control-S (Save) for VTube Project Files
These new hotkeys are a simple thing- but they'll make your life much easier if you're a hotkey user. (The new project save notification window described above will display every time you press CTRL-S.) |
NEW: CALCULATE TUBE ELONGATION PERCENTAGE FEATURE
Now VTube-LASER can calculate Tube Elongation Percentage by subtracting the current CUT LENGTH from the MEASURED LENGTH - then calculate the percentage by comparing that change to the total ARC LENGTHS in the measured tube. |
ENHANCEMENT and FIX: The PROBE RADIUS COMPENSATION Feature
If you measure the ends of tubes with the ball probe, and the probe radius compensation directions at either end are ever different, then this update is critical for you. CHANGED CAPTIONS IN SETUP |
FIX: Transfluid XYZ Output (BKT File) Repairs
This feature allows you to output new XYZ data to the bender from inside VTube-STEP (which is part of VTube-LASER). |
OTHER CHANGES
- When decreasing the point count in VTube-LASER without clearing the project, the reports would continue to show the previous expanded point count for the Tangent Points and Midpoints list. This has been fixed.
- The Overbend Calculator incorrected swapped the Proportional and Fixed values in the springback formula for the springback grid inside the calculator. This has been fixed.
- The Springback compensation, when enabled, was not calculated correctly in outgoing Supravision files. This has been fixed.
- The End B Length Adjustment feature would not draw the tube diameter correctly when set to more than or less than 0. This has been fixed.