|
|
Line 53: |
Line 53: |
| [[image:elpremier_vector_screen_002.png|500px]] | | [[image:elpremier_vector_screen_002.png|500px]] |
| </td> | | </td> |
− | </tr>
| |
− | </table>
| |
− |
| |
− | ==Handles all the Eaton Leonard Data in Transfers==
| |
− | <table>
| |
− | <tr>
| |
− | <td width=300 valign="top">
| |
− |
| |
− | ===YBC Velocity, Function, Stop, and C Last Included===
| |
− | This data includes all the part setup data and all the data that is included in each YBC row, including these data columns:<br><br>
| |
− |
| |
− | * Y
| |
− | * Y Velocity
| |
− | * Y Function
| |
− | * Y Stop
| |
− | * B
| |
− | * B Velocity
| |
− | * B Function
| |
− | * B Stop
| |
− | * C
| |
− | * C Velocity
| |
− | * C Function
| |
− | * C Stop
| |
− | * C Last
| |
− | <br><br>
| |
− | Click on the image on the right so see a close-up of this screen.<br><br><br>
| |
− |
| |
− | ===YBC Data Automatically Synchronized with Blue Column LRA Data in the Parent Window===
| |
− | The YBC data in this Eaton Leonard Setup window is always synchronized with the blue columns in the parent VTube Bender Setup window.<br><br>
| |
− | Change the data in either window, and the corresponding data in the other window will automatically change.<br><br>
| |
− |
| |
− | ===Use Either Inches or Millimeters===
| |
− | The screen allows you to switch between Inches and Millimeters and back again with the press of a single button.
| |
− |
| |
− |
| |
− |
| |
− | <br>
| |
− | <br>
| |
− |
| |
− | </td>
| |
− |
| |
− | <td valign="top">
| |
− | [[image:vtube-laser_bendersetup_eatonleonard_synchronized.png|600px]]<br><br>
| |
− | </td>
| |
− |
| |
| </tr> | | </tr> |
| </table> | | </table> |
Revision as of 05:03, 1 December 2016
VTube-LASER uses the legacy Eaton Leonard Current Loop protocol to communicate with Premier controls. The protocol requires that an RS-232 signal be converted to Current Loop, then sent to the bender.
This diagram demonstrates how a Benderlink Ethernet Module completes the Current Loop connection between a FARO VTube-LASER computer to an Eaton Leonard Premier, or EL-2000 bender control.
The Benderlink Ethernet Module can be wired or WiFi wireless (optional).
|
|
How to Use Communication Between the Premier and VTube-LASER
Communications between VTube-LASER and the Premier is very easy to do because it's robust and also very intuitive.
All communications from the PREMIER control occurs in the VECTOR 1 screen shown here.
VTube-LASER knows how to communicate using the VECTOR 1 protocol.
When you enter this screen note that the REQUEST TRANSFER box on the right is BLACK. This means that the Premier is not ready for communications yet.
|
|
To put the Premier in communications mode, make the REQUEST TRANSFER box active (green) like is shown here. The WAITING field will be highlighted.
Before you make that button active, check on the following settings:
CHECK 1 - CORRECT MODE IS ACTIVE
The MODE in the upper left corner should read "EXTERNAL MODE". It is controlled by the yellow button on the bottom right side of the screen. This mode allows VTube-LASER to control the communications.
CHECK 2 - BENDER NUMBER MATCHES
The bender number in both this menu and the VTube-LASER Benderlink setup must agree. If they don't, then VTube and the PREMIER will at least issue warnings or dialogs.
CHECK 3 - CORRECT PART NAME IS ON THE SCREEN
If you plan on using the RECALL inside VTube-LASER, then it is important that the correct part name shows in the Part Name field.
If the part names don't match during a VTube-LASER RECALL, then communications will fail. (VTube-LASER sends a 4 byte request, then the PREMIER returns a short 20 byte answer - which is not an entire part, then VTube will time-out.)
|
|
SENDING from VTube-LASER to the PREMIER
Before sending data to a legacy Eaton Leonard control, you can completely setup the control inside VTube-LASER if you have VTube-LASER version 2.7 or greater. VTube-LASER will allow for the complete setup of all bender and setup data that can be stored in a Premier, EL2000, or Velog control in the Eaton Leonard Setup window.
|
|
Sending a NEW Part
- Bring new part data into the Bender Setup window by using the Setup this Window button on the right.
- Press the new "Additional Bender Data" button at the top of the Bender Setup screen to load the Eaton Leonard Setup window.
- Setup the Eaton Leonard
Remember that VTube-LASER Data OVERWRITES ALL DATA at the EL control When SENDING to the PREMIER
Sending a NEW PART
To send a new part, use the BENDER SETUP menu on the right side of the Bend
|
|
Other Pages