Difference between revisions of "VTube-LASER to Eaton Leonard Premier Communications Tutorial"
(→Sending a NEW Part) |
(→Sending a NEW Part) |
||
Line 72: | Line 72: | ||
==Sending a NEW Part== | ==Sending a NEW Part== | ||
# If the blue columns only have zeros, or there are no rows in the LRA grid, bring new part data into the Bender Setup window by using the Setup this Window button on the right. Click on "Copy MASTER LRA to Setup LRA".<br><br> | # If the blue columns only have zeros, or there are no rows in the LRA grid, bring new part data into the Bender Setup window by using the Setup this Window button on the right. Click on "Copy MASTER LRA to Setup LRA".<br><br> | ||
− | # Press the "'''Additional Bender Data'''" button at the top of the Bender Setup screen to load the Eaton Leonard Setup window. Edit any of the Eaton Leonard setup values.<br><br> | + | # Press the "'''Additional Bender Data'''" button at the top of the Bender Setup screen to load the Eaton Leonard Setup window. Edit any of the Eaton Leonard setup values and Save and Close that window.<br><br> |
# Press "Setup the Bender" on the right.<br><br> | # Press "Setup the Bender" on the right.<br><br> | ||
# Press "AUTO SEND" on the right. (Be sure that the bender is ready for communication. See the "Premier VECTOR 1 Menu With Communications Active" section above.) | # Press "AUTO SEND" on the right. (Be sure that the bender is ready for communication. See the "Premier VECTOR 1 Menu With Communications Active" section above.) |
Revision as of 05:14, 1 December 2016
VTube-LASER uses the legacy Eaton Leonard Current Loop protocol to communicate with Premier controls. The protocol requires that an RS-232 signal be converted to Current Loop, then sent to the bender. |
Contents |
How to Use Communication Between the Premier and VTube-LASER
Communications between VTube-LASER and the Premier is very easy to do because it's robust and also very intuitive.
The Initial Premier VECTOR 1 Menu
All communications from the PREMIER control occurs in the VECTOR 1 screen shown here. |
Premier VECTOR 1 Menu With Communications Active
To put the Premier in communications mode, make the REQUEST TRANSFER box active (green) like is shown here. The WAITING field will be highlighted. CHECK 1 - CORRECT MODE IS ACTIVE |
SENDING from VTube-LASER to the PREMIER
Before sending data to a legacy Eaton Leonard control, you can completely setup the control inside VTube-LASER if you have VTube-LASER version 2.7 or greater. VTube-LASER will allow for the complete setup of all bender and setup data that can be stored in a Premier, EL2000, or Velog control in the Eaton Leonard Setup window. |
|
Sending a NEW Part
|
Other Pages
- See VTube-LASER to Premier, EL2000, Velog Data Transfer
- Back to the Benderlink Ethernet Module Page
- Back to VTube-LASER
- Back to Eaton Leonard