Difference between revisions of "VTube-LASER Cylinder Fit Tolerances"
(→Wobble Deviation - The highest of the X or Y values) |
(→Wobble Deviation - The highest of the X or Y values) |
||
Line 53: | Line 53: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400> | <td width=400> | ||
− | To simplify visualizing the X and Y Position deviation, we say that the '''highest of the X and Y values is the "wobble deviation"'''. The wobble deviation in the example on the right is 0.21 inches - because | + | To simplify visualizing the X and Y Position deviation, we say that the '''highest of the X and Y values is the "wobble deviation"'''. The wobble deviation in the example on the right is 0.21 inches - because it is the higher of the two values.<br><br> |
If the centerline calculation is very good, then wobble deviation decreases. If the calculation or fit is poor, then the wobble deviation is too high.<br><br> | If the centerline calculation is very good, then wobble deviation decreases. If the calculation or fit is poor, then the wobble deviation is too high.<br><br> | ||
VTube-LASER uses the wobble deviation to determine if it should ask you to remeasure the cylinder. | VTube-LASER uses the wobble deviation to determine if it should ask you to remeasure the cylinder. |
Revision as of 17:35, 20 February 2017
|
"How Well Does Centerline Fit the Cylinder Surface Points?"
VTube-LASER uses surface points scanned with laser or measured with ball probes to calculate tube centerlines. |
The Cylinder Fit Data Window Reports How Well the Centerline Fits the Surface Data
After calculating a cylinder centerline from surface points, VTube-LASER reports how well the centerline FITS the surface points of the cylinder. These values are shown in the Cylinder Fit Data window.
These estimate values are calculated using statistical math. The values are standard deviation x 2, which means that we have 95% assurance that the these values are the maximum deviation. |
Wobble Deviation - The highest of the X or Y values
To simplify visualizing the X and Y Position deviation, we say that the highest of the X and Y values is the "wobble deviation". The wobble deviation in the example on the right is 0.21 inches - because it is the higher of the two values. |
Default Cylinder Fit Tolerances
To allow VTube-LASER to warn for poor cylinder measurements, it stores tolerances for the allowed deviations during cylinder fit. These values are often setup in the Measure 1 tab of the System Options menu. |
Recommended Aerospace Cylinder Fit Tolerances
Aerospace-grade materials are often very precise. For aerospace applications, we strongly recommend that you consider using tighter tolerances like these shown here. |
How to Test for Your Ideal Tolerances
You can test for ideal cylinder fit tolerance settings by watching the tolerance values in the Cylinder Fit window when measuring a tube. |
Other Pages
- Back to VTube-LASER
- Back to VTube-STEP