Difference between revisions of "VTube-LASER v2.8.1"
(→25px NEW: SECOND POINT OBJECT for END OFFSETS) |
(→25px NEW: SECOND POINT OBJECT for END OFFSETS) |
||
Line 32: | Line 32: | ||
This feature adds a second end point object on the screen for the end point before it is offset.<br><br> | This feature adds a second end point object on the screen for the end point before it is offset.<br><br> | ||
The extra model lets you visually confirm that the final offset point (orange) is based on the correct datum point (yellow) when a A-End or B-End Measured offset value is entered, and/or a ball probe is used on the end.<br><br> | The extra model lets you visually confirm that the final offset point (orange) is based on the correct datum point (yellow) when a A-End or B-End Measured offset value is entered, and/or a ball probe is used on the end.<br><br> | ||
− | In the top | + | In the top-right image, the yellow ball represents the middle of the ball probe. The orange ball is the projected end point based on the compensation toward the end.<br><br> |
[[image:vtube-laser_v2.8.1_end_offset_model_illustration.png|300px]]<br><br> | [[image:vtube-laser_v2.8.1_end_offset_model_illustration.png|300px]]<br><br> | ||
When the two points are within 0.1 mm (0.0039 inches) of within each other, then VTube only draws the final orange ball. | When the two points are within 0.1 mm (0.0039 inches) of within each other, then VTube only draws the final orange ball. |
Revision as of 02:50, 7 May 2017
Revision 2.8.1Original Release Date: May 8, 2017
|
Contents |
BUILD 70 - May 6, 2017
NEW: SECOND POINT OBJECT for END OFFSETS
NEW: NOTIFICATION SWITCHING FROM LASER SCANNER TO BALL PROBE and BACK
As of this version if VTube-LASER toggles from LASER to ball probe or ball probe to LASER, it notifies you with a sound and a guide box message. |
NEW: SWITCH BETWEEN UNISCAN TO MULTISCAN IN THE SAME TUBE
As of this version if VTube-LASER allows you to toggle UNISCAN to MULTISCAN and back in the SAME tube. |
NEW: UNISCAN DCF (DUAL CYLINDER FIT) ADDED TO MULTISCAN
The DCF feature was only available in UNISCAN in the previous version. Now it is used in MULTISCAN too. |
Other Features and Fixes
|
Other Pages
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature