Difference between revisions of "VTube-LASER v2.8.1"
(→25px NEW: SECOND POINT OBJECT for END OFFSETS) |
(→25px NEW: SECOND POINT OBJECT for END OFFSETS) |
||
Line 32: | Line 32: | ||
This feature adds a second end point object on the screen for the end point before it is offset.<br><br> | This feature adds a second end point object on the screen for the end point before it is offset.<br><br> | ||
The extra model lets you visually confirm that the final offset point (orange) is based on the correct datum point (yellow) when a A-End or B-End Measured offset value is entered, and/or a ball probe is used on the end.<br><br> | The extra model lets you visually confirm that the final offset point (orange) is based on the correct datum point (yellow) when a A-End or B-End Measured offset value is entered, and/or a ball probe is used on the end.<br><br> | ||
− | In | + | In these images, the yellow ball represents the middle of the ball probe. The orange ball is the projected end point based on the compensation toward the end plus the negative or positive offset values in Part Setup.<br><br> |
[[image:vtube-laser_v2.8.1_end_offset_model_illustration.png|300px]]<br><br> | [[image:vtube-laser_v2.8.1_end_offset_model_illustration.png|300px]]<br><br> | ||
When the two points are within 0.1 mm (0.0039 inches) of within each other, then VTube only draws the final orange ball. | When the two points are within 0.1 mm (0.0039 inches) of within each other, then VTube only draws the final orange ball. |
Revision as of 02:51, 7 May 2017
Revision 2.8.1Original Release Date: May 8, 2017
|
Contents |
BUILD 70 - May 6, 2017
NEW: SECOND POINT OBJECT for END OFFSETS
NEW: NOTIFICATION SWITCHING FROM LASER SCANNER TO BALL PROBE and BACK
As of this version if VTube-LASER toggles from LASER to ball probe or ball probe to LASER, it notifies you with a sound and a guide box message. |
NEW: SWITCH BETWEEN UNISCAN TO MULTISCAN IN THE SAME TUBE
As of this version if VTube-LASER allows you to toggle UNISCAN to MULTISCAN and back in the SAME tube. |
NEW: UNISCAN DCF (DUAL CYLINDER FIT) ADDED TO MULTISCAN
The DCF feature was only available in UNISCAN in the previous version. Now it is used in MULTISCAN too. |
Other Features and Fixes
|
Other Pages
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature