Difference between revisions of "VTube Communication for UNISON Benders"

From ATTWiki
Jump to: navigation, search
(STEP 2 - Measure the tube with VTube-LASER)
(STEP 3 - Enter BENDER SETUP)
Line 280: Line 280:
  
 
<td>
 
<td>
[[image:VTube-LASER CRIPPA Click on Bender Setup.png|400px]]<br><br>
+
[[image:VTube-LASER UNISON Click on Bender Setup.png|400px]]<br><br>
 
</td>
 
</td>
 
</tr>
 
</tr>

Revision as of 22:56, 11 February 2018

Vtube-step logo 2.pngVtube-laser logo 1.96.png

UNISON SVNet Logo.png UNISONBreezeBender.png

This page describes the use of the VTube to UNISON Supravision file communications. Descriptions for VTube-STEP and VTube-LASER are included.



Contents


Protocol

VTube-STEP can send data directly to the UNISON LTD software YBC values.

VTube-LASER can correct data in UNISON LTD for YBC bender corrections.

Vtube-laser communication with UNISON.png


UNISON CONTROL SETUP

The connection uses a standard network connection between Windows computers. You will need to attach the UNISON bender to a standard network to allow this kind of communication.

You can share a folder on the UNISON with the VTube-LASER computer, or you can allow the UNISON control to gain access to a network location for READ/WRITE access.

Please ask UNISON technicians for assistance in making a connection.

YBC --> Supravision Screen

The Supravision screen in is where all communications occur. You can press the measuring center button in the YBC screen to load the Supravision screen.

Bender Number

The Supravision Network protocol requires that the bender number at the control match the bender number in VTube-LASER. so, it is important to know what bender number is being used for this bender in the VTube setup. (Make the two numbers match.)


UNISON YBC Screen Press Measuring Center Button.png

UNISON Supravision Bender Number.png

BENDERLINK SETUP STEPS FOR VTUBE-STEP AND VTUBE-LASER

You can perform this setup from VTube-STEP or VTube-LASER. The steps are identical in both.

STEP 1: Enter the SYSTEM OPTIONS Menu in VTube

  1. Load VTube.

  2. Click on Systems Options in the toolbar at the top of the screen.

  3. Enter the Measure 2 tab menu.

  4. Enter the Setup Benderlink Network menu.

VTube System Options Benderlink Network Button.png

STEP 2: Setup the Benderlink Network Grid for UNISON Supravision Network Protocol

  1. Choose an unused row in the grid for a new UNISON bender setup.

  2. Assign a bender name that will help operators identify which bender this is. This text will be displayed at the top of the Bender Setup menu.

  3. Assign the Supravision Network protocol.

  4. Enter the path to the shared drive or folder in the NetPath field. This path should point to the UNISON folder that will receive command files from VTube. (The value shown on the screen is only an example.)

  5. Enter the IP address in the PING IP ADDRESS field if it is a fixed field. (This is not required. It allows VTube to ping the address to see if the network location is active before trying to open communications.)

  6. If the UNISON rotates the Clockwise positive, then select YES in the CW Rotation Positive cell.

  7. The "Ignore Incoming Linear Unit" setting is optional. This will not allow the UNISON to change the linear units in VTube-LASER if they are different.

  8. Press Close to save the settings. VTube will save these values to a persistent configuration file that will not change unless you change them in this grid.

Benderlink Network Unison SVNET.png







HOW TO SEND AND RECALL DATA FROM VTUBE-STEP AND VTUBE-LASER

Vtube-step logo 2.png How to SEND MASTER XYZ Data to the CRIPPA Control from VTube-STEP

You can import data or models into VTube-STEP then send the calculated LRA bender data to the CRIPPA bender using the VTube BENDER OUTPUT menu.

STEP 1 - Use the BENDER OUTPUT Menu

  1. The BENDER OUTPUT menu can be loaded from the NAVIGATION PANE. Inside that menu...

  2. Select the bender number.

  3. Click on "Send to Bender"

  4. The Send to Bender Complete window will appear. This means that VTube has dropped the data file in the location where the UNISON control can automatically load the file and its data into UII.

VTube-STEP Send Tube Data to UNISON SVNet.png

VTube-STEP Send Tube Data to UNISON SVNet Complete.png

STEP 2 - IMPORT the Data at the UNISON Control

In the YBC page, press the measuring center button.

UNISON YBC Screen Press Measuring Center Button.png

STEP 3 - READ NOMINAL

  1. Select the file that VTube-STEP just built. (You will need to find it on the network.)

  2. Press "Read Nominals" button

UNISON Read Nominal.png

Vtube-laser logo 1.96.png How to SEND MASTER LRA Data to the UNISON Control from VTube-LASER

You can also send the new LRA data from the VTube-LASER BENDER SETUP menu to the UNISON bender using the VTube Bender Output menu.

STEP 1 - Enter the BENDER SETUP menu in VTube-LASER

Press the "BENDER SETUP button in the Navigation Pane.

Vtube-laser navpane bendersetup orangetube.png

STEP 2 - Choose the BENDER NUMBER

Set the correct bender number at the top of the window.

You can select up to 100 different benders.

The Bender Protocol should say "Supravision Network". (This assumes that you have already configured VTube's Benderlink in the Systems Options as described in the previous VTube-STEP section.)

VTube-LASER UNISON Bender Setup Bend Number.png

STEP 3 - Setup the Bender Setup Data in this WINDOW

This is for first-time setup for a new part. Data in this window is separate from data in the main VTube-LASER window, so it is necessary to bring data into this window when performing first-time setup of a part. This ensures that the correct data is sent to the UNISON.

  • Click on "Setup this Window" in the expanding menu on the right.

  • Click on copy MASTER LRA to SETUP LRA.

  • Be sure every field in the top panel has data that you want to send to the UNISON.

  • The blue columns below will eventually be converted to new YBC data at the bender. So check for numbers there.

VTube-LASER UNISON Copy Master LRA.png

STEP 3 - Send data to the UNISON BENDER

  • Click on "Setup the Bender" in the expanding menu on the right.

  • Click on "AUTO SEND the MASTER XYZ + BLUE Columns to the Bender".

VTube-LASER UNISON Auto Send Master Data.png

STEP 4 - The Send to Bender Complete Window

A window indicating that data was sent should appear for a few seconds then disappear automatically.

VTube-LASER UNISON Send to Bender Complete.png

STEP 5 - IMPORT the Data at the UNISON Control

In the YBC page, press the measuring center button.

UNISON YBC Screen Press Measuring Center Button.png


STEP 6 - READ NOMINAL

  1. Select the file that VTube-LASER just built. (You will need to find it on the network.)

  2. Press "Read Nominals" button

UNISON Read Nominal.png

Vtube-laser logo 1.96.png How to SEND CORRECTION Data to the UNISON Control from VTube-LASER

STEP 1 - Bend the Tube

Bend the tube in the UNISON.

UNISON User Programming Control.png

STEP 2 - Measure the tube with VTube-LASER

Measure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape.

In the screen shot on the right, the red on the top left shows that the first END "A" LENGTH is out of tolerance.

Also, the red cells in the tangent point grid show that the measured tube centerline shape is out-of-tolerance.

Also - VTube is very visual. The solid model on the right shows exactly where the part is out is exceeding the tolerance. Click on the image to zoom in to see the values.

VTube-LASER UNISON Inspection Result.png

STEP 3 - Enter BENDER SETUP

Click on the BENDER SETUP button in the Navigation Pane.

VTube-LASER UNISON Click on Bender Setup.png

For dual screen systems, VTube-LASER will let you press the Switch Screens button in the upper right corner in order to move the Bender Setup window to the second screen like this:

See VTube-LASER Multiple Screen Support for more information about this feature.

VTube-LASER CRIPPA Bender Setup Dual Screen.png

Multi-screen support bender setup.png

STEP 4 - Choose the BENDER NUMBER

Set the correct bender number at the top of the window.

You can select up to 100 different benders.

You should see a CRIPPA icon at the top left corner of the screen. The Bender Protocol should say "CRIPPA SupravisionNET". (This assumes that you have already configured VTube's Benderlink in the Systems Options as described in the previous VTube-STEP section.)

VTube-LASER CRIPPA Bender Setup Correction - Set Bender Number.png

STEP 5 - RECALL CRIPPA YBC data

Be sure the that the Part Number value is the same as the part name in the CRIPPA control. The CRIPPA will not return data unless it recognizes the part number.

Remember that the CRIPPA UII will only return data from the part that is SAVED TO THE DISK. It will not return UNSAVED data in the UII screen.

In the Bidirectional Communication menu on the right, click on RECALL.

RECALLING data is a critical step during correction. If a RECALL is not performed before a CORRECTION, then VTube may not be able make adjustments to the correct starting YBC data. Be sure to perform this step before performing the CORRECTION step below.

VTube-LASER CRIPPA RECALL LRA.png

STEP 6 - OPTIONAL STEP - You Can Manually Change the ADJUSTMENT Values

You can manually change the ADJUSTMENT values before sending corrections if you want to. Some users like to set the first and last Length adjustment to zero in order to keep the start position of the carriage in the same place - for when they have extra length on the ends.

If you want to, it is even possible to invert the rotation direction to keep the tube from hitting the bender during rotations.

VTube-LASER CRIPPA Manually Adjust Correction Values.png

STEP 7 - Send the CORRECTION Values to the CRIPPA

Click on AUTO SEND. This will send the ORANGE columns to the CRIPPA bender.

To be sure that a RECALL has recently been performed, VTube will show a CRIPPA CORRECTIONS NOTES as a reminder.


VTube-LASER CRIPPA Send Orange Column Data.png

STEP 8 - The SEND ADJUSTED Window

A window should appear for a few seconds indicating that the Send to the Bender is complete.

VTube-LASER CRIPPA Send Adjusted Complete.png

STEP 9 - SAVE the New Data at the CRIPPA UII Software

Move to the CRIPPA control. CRIPPA will ask for confirmation to update when it receives the incoming data. Say "Yes".

If you don't see this green banner, then communications did not occur. You will need to trouble-shoot the connection to make it work.

The YBC data will change to match the data that was sent from VTube. You can compare a few values to be sure the data was updated properly.

The VTube-LASER SEND will only update the UII data on the CRIPPA screen. (Remember: CRIPPA only returns data from the file - see "RECALL" above.) This new data that the CRIPPA UII screen just received from VTube-LASER must be SAVED to the disk and compiled to take effect.

CRIPPA UII Supravision Update Confirmationld.png

STEP 10 - REPEAT STEPS 1 THROUGH 9

Bend the tube in the CRIPPA (Step 1) then measure it again (Step 2) and follow the rest of the steps until the part is within tolerance.

CRIPPA User Programming UII.png

Other Pages