Revision as of 14:39, 17 September 2018
|
About Nearest Pass
The point at which two 3D lines are the closest to each other is where they come closest to intersecting. The distance is the “nearest pass.” |
How it is used in VTube-LASER
VTube-LASER checks for and displays the Nearest Pass value when measuring two intersecting tube straights. If the value is too high, then VTube-LASER will ask you to remeasure the tube until the value is within tolerance. The default tolerance for Nearest Pass is 2mm. |
How To Change the Tolerance
You can change the tolerance by entering System Options, Measure 1 menu and changing the Maximum Near Pass Deviation Allowed value. |
|