Difference between revisions of "CNC Bender v10-20070920"
From ATTWiki
(→Explanation) |
(→Solution To Issue) |
||
Line 24: | Line 24: | ||
− | This version solves the | + | This version solves '''avoids the possible corruption of data''' by placing an intentional delay between the time the operator requests a shutdown and the time the configuration data is written to disk and registry. |
<br><br> | <br><br> | ||
The delay message looks like this. It contains a progress bar that fills over about a 10 second period. | The delay message looks like this. It contains a progress bar that fills over about a 10 second period. | ||
Line 48: | Line 48: | ||
</ul> | </ul> | ||
− | |||
− | |||
=UPGRADE= | =UPGRADE= |
Revision as of 20:26, 20 September 2007
Contents |
NEW FEATURE: Improved and Safer Shutdown
Explanation
- CNC Bender software saves its current state and setup in a configuration files and registry entries during shutdown.
- If the standard shutdown procedure is bypassed due to a loss of power or a system crash, then CNC Bender, in previous versions, may attempt to write data - only to be interrupted in the shutdown task.
- The result is a possible corruption of this file. If the file is corrupted, then the configuration for that bender will be lost and must be recovered using one of couple methods of recovery.
Solution To Issue
-
This version solves avoids the possible corruption of data by placing an intentional delay between the time the operator requests a shutdown and the time the configuration data is written to disk and registry.
- The operator requests shutdown of software.
- CNC Bender hides the interface.
- CNC Bender displays a shutdown message on the screen showing a progress bar.
- After the progress bar is filled, CNC Bender saves its configuration data.
- A loss of power to the operator station occurs.
- CNC Bender is not given time to perform a normal shutdown because the delay progress will not be filled.
- CNC Bender will shutdown before it attempts to save a partial file and potentially corrupts the configuration data.
The delay message looks like this. It contains a progress bar that fills over about a 10 second period.
During a Regular Shutdown
During an Immediate Power Loss Shutdown
UPGRADE
- Contact Advanced Tubular Technologies for upgrade information.