Difference between revisions of "VTube-STEP v2.9.19"
(→25pxNEW - Selection Inversion Method Helps Select Parts in an Assembly) |
(→25pxNEW - Choose to Give Priority to XYZ or LRA Data Import in Supravision Files) |
||
(7 intermediate revisions by one user not shown) | |||
Line 4: | Line 4: | ||
[[image:vtube-step_logo_2.png|300px]] | [[image:vtube-step_logo_2.png|300px]] | ||
==Version 2.9.19== | ==Version 2.9.19== | ||
− | Release Date: April | + | Release Date: April 29, 2019<br> |
− | Build: | + | Build: 16 |
Line 22: | Line 22: | ||
<br><br> | <br><br> | ||
__TOC__ | __TOC__ | ||
− | |||
==[[image:Check.jpg|25px]]NEW - VTube-STEP Mode Alpine M4 and CSM M4 export filenames can use more than 20 characters. == | ==[[image:Check.jpg|25px]]NEW - VTube-STEP Mode Alpine M4 and CSM M4 export filenames can use more than 20 characters. == | ||
Line 43: | Line 42: | ||
</table> | </table> | ||
− | |||
− | <table cellpadding=10 width= | + | ==[[image:Check.jpg|25px]]NEW - IMPORT SUPRAVISION - Choose to Give Priority to XYZ or LRA Data Import in Supravision Files == |
+ | |||
+ | <table cellpadding=10 width=1400> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | + | VTube-STEP now allows you to choose which data section to give priority to during import of tube shape data in Supravision files.<br><br> | |
− | + | This overcomes issues were data files contain [[XYZ data]] and [[LRA data]] that do not match. You choose which section you want to use as the defining data.<br><br> | |
+ | This logic also will ignore a section if it is invalid (ie, it is all zeros or is not present). | ||
+ | </td> | ||
<td> | <td> | ||
− | [[image: | + | [[image:vts_v2.9.19_svimport_sectionchoice.png|700px]]<br> |
</td> | </td> | ||
Line 60: | Line 62: | ||
</table> | </table> | ||
− | + | ==[[image:Check.jpg|25px]]NEW - IMPORT EATON LEONARD PRT - Choose to Give Priority to XYZ or YBC Data Import in PRT Files == | |
− | + | <table cellpadding=10 width=1400> | |
− | + | ||
− | <table cellpadding=10 width= | + | |
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | + | VTube-STEP now allows you to choose which data section to give priority to during import of tube shape data in EL PRT files.<br><br> | |
+ | This overcomes issues were data files contain [[XYZ data]] and [[YBC data]] that do not match. You choose which section you want to use as the defining data.<br><br> | ||
+ | This logic also will ignore a section if it is invalid (ie, it is all zeros or is not present). | ||
+ | </td> | ||
<td> | <td> | ||
− | [[image: | + | [[image:vts_v2.9.19_prtimport_sectionchoice.png|700px]]<br> |
</td> | </td> | ||
Line 77: | Line 80: | ||
</table> | </table> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
==Other Pages== | ==Other Pages== |
Latest revision as of 21:19, 29 April 2019
Version 2.9.19Release Date: April 29, 2019
|
NEW - VTube-STEP Mode Alpine M4 and CSM M4 export filenames can use more than 20 characters.
VTube-LASER would not allow VTube-STEP to export an MBF filename with more than 20 characters. Alpine and CSM have changed this limitation for the characters in the filename, so we have changed it in VTube-STEP as well. |
NEW - IMPORT SUPRAVISION - Choose to Give Priority to XYZ or LRA Data Import in Supravision Files
VTube-STEP now allows you to choose which data section to give priority to during import of tube shape data in Supravision files. |
NEW - IMPORT EATON LEONARD PRT - Choose to Give Priority to XYZ or YBC Data Import in PRT Files
VTube-STEP now allows you to choose which data section to give priority to during import of tube shape data in EL PRT files. |
Other Pages
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See Customer Support Page to download the latest version.