Difference between revisions of "VTube NUMALLIANCE Bender Correction"

From ATTWiki
Jump to: navigation, search
(STEP 2)
(STEP 9)
 
(8 intermediate revisions by one user not shown)
Line 68: Line 68:
 
If the data in the window is not correct, then import the data from the main VTube-LASER memory by clicking on "Setup this Window" then clicking on "Copy Master LRA to Setup LRA".
 
If the data in the window is not correct, then import the data from the main VTube-LASER memory by clicking on "Setup this Window" then clicking on "Copy Master LRA to Setup LRA".
 
<br><br>
 
<br><br>
In the "Correct the Bender" menu, click on Auto Send. This will save a correction file with the filename extension MES on the network.
+
In the "Correct the Bender" menu, click on Auto Send.
 +
<br><br>
 +
A save file dialog will open and allow you to name the MES file on a thumb drive or on the network.  This file will be imported into the NUMALLIANCE control.
  
 
</td>
 
</td>
Line 86: Line 88:
  
 
<td width=300>
 
<td width=300>
Choose the NUMALLIANCE CSV File option in the pulldown list.
+
At the NUMALLIANCE control, press the CAD button.
 +
<br><br>
  
 
</td>
 
</td>
  
 
<td>
 
<td>
[[image:NumallianceCorrectionSlide4.png|800px]]
+
[[image:NumallianceCADbutton.png|800px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 97: Line 100:
 
</table>
 
</table>
 
<br><br>
 
<br><br>
 
  
 
==STEP 4==
 
==STEP 4==
Line 105: Line 107:
  
 
<td width=300>
 
<td width=300>
click the Export button.<br><br>
+
Press the XYZ/LRA button.<br><br>
 
</td>
 
</td>
  
 
<td>
 
<td>
[[image:NumallianceCorrectionSlide5.png|800px]]
+
[[image:NumallianceXYZLRA.png|800px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 122: Line 124:
  
 
<td width=300>
 
<td width=300>
It is very important to enable the Positive Rotation options for most NUMALLIANCE benders.  They normally rotate positive Clockwise when standing from the front of the bender.  
+
Press the File button.
 
<br><br>
 
<br><br>
If this setting is incorrect, then the rotations will be corrected in the wrong direction and cause the part to move further away from the nominal master part.
+
Press the Import corrections button.
  
 
</td>
 
</td>
  
 
<td>
 
<td>
[[image:NumallianceCorrectionSlide6.png|800px]]
+
[[image:NumallianceFileAndImport.png|800px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 142: Line 144:
  
 
<td width=300>
 
<td width=300>
Click on the Set the Filename button.
+
Open the file from VTube.
 
+
</td>
+
 
+
<td>
+
[[image:NumallianceCorrectionSlide7.png|800px]]
+
</td>
+
</tr>
+
 
+
</table>
+
<br><br>
+
 
+
==STEP 7==
+
 
+
<table cellpadding=10 width=1200>
+
<tr valign=top>
+
 
+
<td width=300>
+
Choose the export path in the Path Manager.
+
 
+
</td>
+
 
+
<td>
+
[[image:NumallianceCorrectionSlide8.png|800px]]
+
</td>
+
</tr>
+
 
+
</table>
+
<br><br>
+
 
+
 
+
==STEP 8==
+
 
+
<table cellpadding=10 width=1200>
+
<tr valign=top>
+
 
+
<td width=300>
+
Save the CSV file.
+
 
+
</td>
+
 
+
<td>
+
[[image:NumallianceCorrectionSlide9.png|800px]]
+
</td>
+
</tr>
+
 
+
</table>
+
<br><br>
+
 
+
==STEP 9==
+
 
+
<table cellpadding=10 width=1200>
+
<tr valign=top>
+
 
+
<td width=300>
+
Import the file into the NUMALLIANCE control.
+
  
 
</td>
 
</td>
  
 
<td>
 
<td>
[[image:NumallianceCorrectionSlide10.png|800px]]
+
[[image:NumallianceOpenMESfile.png|800px]]
 
</td>
 
</td>
 
</tr>
 
</tr>

Latest revision as of 23:29, 25 November 2019

VTube-LASER AssemblyOverModel.png RightOrangeArrow.png Numalliance Splash.png

This page describes how to use VTube-LASER to correct NUMALLIANCE benders.



Back to VTube-LASER

Contents


NUMALLIANCE CORRECTIONS

VTube-LASER has an export option for NUMALLIANCE MES files that are used to correct the NUMALLIANCE benders.

Note: NUMALLIANCE benders only require the measured data for corrections.

Measure the tube in VTube-LASER, then send the MEASURED tube data to the bender control, and it will then perform the correction.

Follow the steps below.

NumallianceCorrectionsSlide1.png



STEP 1

Press the Bender Setup button. (These steps assume that you have measured the tube and have setup VTube-LASER with the NUMALLIANCE protocol.)

Numalliance1.png



STEP 2

Set the bender number. It should say NUMALLIANCE like shown here.

If the data in the window is not correct, then import the data from the main VTube-LASER memory by clicking on "Setup this Window" then clicking on "Copy Master LRA to Setup LRA".

In the "Correct the Bender" menu, click on Auto Send.

A save file dialog will open and allow you to name the MES file on a thumb drive or on the network. This file will be imported into the NUMALLIANCE control.

Numalliance2.png



STEP 3

At the NUMALLIANCE control, press the CAD button.

NumallianceCADbutton.png



STEP 4

Press the XYZ/LRA button.

NumallianceXYZLRA.png



STEP 5

Press the File button.

Press the Import corrections button.

NumallianceFileAndImport.png



STEP 6

Open the file from VTube.

NumallianceOpenMESfile.png



Other Pages