Difference between revisions of "VTube Software Updates"
From ATTWiki
(→image:Gears_view_small.png VTube-LASER - Fourth Quarter - 2017) |
(→image:Gears_view_small.png VTube-LASER - Version 3 - Version Control Report) |
||
(277 intermediate revisions by one user not shown) | |||
Line 5: | Line 5: | ||
See a complete list of VTube updates on this page.<br><br> | See a complete list of VTube updates on this page.<br><br> | ||
− | * Back to [ | + | * Back to [https://www.advancedtubular.net/vtube-laser.html the Main VTube-LASER] web page |
* Back to [[VTube-LASER]] Knowledgebase Page | * Back to [[VTube-LASER]] Knowledgebase Page | ||
* See also [[VTube-STEP Updates]] | * See also [[VTube-STEP Updates]] | ||
Line 11: | Line 11: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | [[image: | + | [[image:vtube-laser_v2.7_screenshot.png|300px]] |
</td> | </td> | ||
</tr> | </tr> | ||
Line 18: | Line 18: | ||
+ | |||
+ | ==== [[image:Gears_view_small.png]] VTube-LASER - Version 3 - Version Control Report==== | ||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr valign=top> | ||
+ | <td width="150">January 11, 2021</td> | ||
+ | <td width="150">Latest Build: 411</td> | ||
+ | <td width="450"> | ||
+ | * [https://www.advancedtubular.com/versions/vtube/Version%20Control%20Report.pdf VTube v3 Version Control Report (PDF)] | ||
+ | * [https://www.advancedtubularsupport.com VTube Support Site for Downloading Updates] | ||
+ | <br><br> | ||
+ | |||
+ | </td> | ||
+ | <td> | ||
+ | |||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ==== [[image:Gears_view_small.png]] VTube-LASER - Third Quarter - 2020==== | ||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr valign=top> | ||
+ | <td width="150">July 15, 2020</td> | ||
+ | <td width="150">[[VTube-LASER v3]]</td> | ||
+ | <td width="450"> | ||
+ | * New INVENTION - SCAN SCORE allows users to compare scan quality with all previous scans | ||
+ | * New - Use math inside floating point edit boxes. | ||
+ | * New - Include an image of the tube in VTube-LASER for pre-measure orientation. | ||
+ | * New – VTube-LASER is optimized for significantly faster internal speed. For example, scanning is 5 times faster | ||
+ | * New - SOLIDWORKS BUILDER now creates orthographic drawings with XYZ grids and LRA grids | ||
+ | * New - User Coordinate System allows you to measure in the coordinate system of an alignment | ||
+ | * New - Quick-add a 90-degree bend to the end of a tube | ||
+ | * New - LRA Spinner lets you jog the Length, Rotation, and Angle, and Radius data. This is helpful for finding the entry and exit angles for coils. | ||
+ | * New - Improved Scanning Sound (changes from click to mallet sound) | ||
+ | * New - Calculate radius from inside radius alone | ||
+ | * New - Qualify Bend Profile ENVELOPE (not just the radius) | ||
+ | * New - Inline Bend Profile Setup: Set up VTube to measure the bend profile of certain bends in tube measure | ||
+ | * New - Three kinds of Bend Profile Scan: Inside, Inside/Outside, All Sides | ||
+ | * New - Unique sounds for all three Bend Profile scan types. | ||
+ | * New – Assembly Alignment: Align one tube in an assembly and pull all other aligned assembly tubes | ||
+ | * New - Assembly Alignment: Control Precision weights across multiple tubes in the assembly | ||
+ | * New - VTube now uses the Windows 10 open and save dialogs (not the Windows 7 dialogs) | ||
+ | * New - UNISON SVNET protocol | ||
+ | * New - Schwarze-Robitec SVNET protocol | ||
+ | * New - YLM SVNET protocol | ||
+ | * New - HEXAGON ISOGEN file import | ||
+ | * New - Import STEP models with ADJACENT bends and no straights. | ||
+ | <td> | ||
+ | |||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ==== [[image:Gears_view_small.png]] VTube-LASER - Second Quarter - 2019==== | ||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr valign=top> | ||
+ | <td width="150">June 12, 2019</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.20]] - Build 10</td> | ||
+ | <td width="450"> | ||
+ | * New - LASER Mode ACCEPT BUTTON TIMER event allows you to never skip pressing the accept button on scanners | ||
+ | * New - VTube-LASER Window is made invisible when entering the FARO scanner options | ||
+ | * New - BLM SVNET Protocol | ||
+ | * New - D of Bend values are shown in the XYZ grids | ||
+ | * New - Newport News Bender Data Grid | ||
+ | * New - Last bender tab menu stored and recalled in the next project | ||
+ | * New – Reports from inside Bender Setup | ||
+ | * New – Added a switch to turn "No Laser Data" sound on or off. | ||
+ | * New - Configuration switch for turning FARO scanner settings update from project files | ||
+ | <td> | ||
+ | [[image:vtubelaser_blmsvnet.png|200px]]<br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr valign=top> | ||
+ | <td width="150">April 29, 2019</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.19]] - Build 16</td> | ||
+ | <td width="450"> | ||
+ | * New - Compatible with HEXAGON Tracker LAS (Leica Absolute Scanner) | ||
+ | * New - Compatible with Baces USB arms | ||
+ | * New - STEP Mode Alpine M4 and CSM M4 export filenames can use more than 20 characters. | ||
+ | * New - Renamed for clarity: The configuration setup list in the Measure 1 menu in System Options is now called "Tolerance Configuration Profile List" | ||
+ | * Fix - Correction data logic for sending data to the COMCO is fixed. | ||
+ | * Fix – Stripe Cut Plane was always on – even when off This is fixed. | ||
+ | * Fix – CSM M3 data sometimes contains negative radius levels. VTube can now handle this data. | ||
+ | <td> | ||
+ | [[image:vtubelaser_bacesarm.png|200px]]<br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ==== [[image:Gears_view_small.png]] VTube-LASER - First Quarter - 2019==== | ||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr valign=top> | ||
+ | <td width="150">March 12, 2019</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.18]] - Build 18</td> | ||
+ | <td width="450"> | ||
+ | # New - AUTOMATIC LASER SEPARATION for UniScan improves laser scanning coverage by adjusting the laser separation distance in real-time. | ||
+ | # New - CORRECTION DATA MAPPING allows you to move corrections up or down or skip them in Bender Data Setup | ||
+ | # New - BLM CMM Protocol makes communications with BLMs much easier | ||
+ | # New - COMCO Protocol allows you to setup and correct COMCO benders. | ||
+ | # New - OMCG Wire bender communication protocol | ||
+ | # New - Default Radii values: Added two additional default radii (Radius 1, 2, and 3) | ||
+ | # New - Syncrhonized any of the three default radii to the tube shapes. | ||
+ | # New - Small diameter warning for when linear values are smaller than normal during import. | ||
+ | # New - Autobuild Parametrics calculates the cut length automatically. | ||
+ | # New - A new button in Tube Data Storage allows you to copy only the MEASURED back into main memory. | ||
+ | # Fix - VTube-LASER now displays an icon in the Task Bar. | ||
+ | # Other changes and fixes<br><br> | ||
+ | [[image:Vts_v2.9.18_BenderSetup_OMCGSVNET.png|200px]][[image:Vts_v2.9.18_BenderSetup_COMCOCSV.png|200px]] | ||
+ | <td> | ||
+ | [[image:ra8_stripes_auto_laser_separation.png|200px]]<br> | ||
+ | [[image:vtl_v2.9.18_BenderSetup_CorrectionMappingCloseUp.png|200px]]<br> | ||
+ | [[image:Vts_v2.9.18_BenderSetup_BLMCMM.png|200px]] | ||
+ | |||
+ | |||
+ | |||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr valign=top> | ||
+ | <td width="150">January 17, 2019</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.17]] - Build 42</td> | ||
+ | <td width="450"> | ||
+ | # Automatic floating Measured Guide Viewport window shows the entire tube during measuring | ||
+ | # Scan point clouds to send to SOLIDWORKS | ||
+ | # Much faster Autobuild Parametrics feature calculates imported parts 5 times faster (STEP mode) | ||
+ | # Change Cylinder Fit tolerances during measurement from a list of setups to scan highly deformed tube | ||
+ | # One-button conversion of models with the new Autobuild Parametrics | ||
+ | # FIVE times faster conversion from STEP and IGES | ||
+ | # Command Server converts STEP and IGES models for external programs | ||
+ | # Client tester program for simulating calling to the new command server | ||
+ | # Now correctly handles 180-degree bend corrections for bender communications | ||
+ | # Automatically display the DRO (Digital Readout) when changing from STEP to LASER mode. | ||
+ | # Automatic set of Straight Count to a non-zero value when measuring | ||
+ | # Limits max points per laser stripe to 50 in UniScan | ||
+ | # Path Manager enhancements | ||
+ | # Better handling of arm connection errors | ||
+ | # Fix in communication of corrections with Eaton Leonard legacy benders | ||
+ | # Added Rad2 and Rad3 fields in Part Setup and Bender Setup to allow for easier conversion to benders that require radius values assigned to levels (like Eaton Leonard and YSE) | ||
+ | # Collected Features menu with new buttons (STEP Mode) | ||
+ | # BLM VGP-3D Bender Data Report | ||
+ | # New Precision Weight Control setup grid popup menu | ||
+ | # Other changes and fixes | ||
+ | <td> | ||
+ | [[image:Vts_v2.9.17_autobuildparametrics_icon.png|200px]]<br><br> | ||
+ | [[image:vtl_v2.9.17_MalibuControlArm_closeup.png|200px]]<br><br> | ||
+ | [[image:vtl_v2.9.17_bucketlist.png|200px]]<br><br> | ||
+ | [[image:vtl_v2.9.17_PointCloudScanToSOLIDWORKS.png|200px]]<br><br> | ||
+ | |||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ==== [[image:Gears_view_small.png]] VTube-LASER - Fourth Quarter - 2018==== | ||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr> | ||
+ | <td width="150">October 19, 2018</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.16]]</td> | ||
+ | <td width="250"> | ||
+ | *New - Reverse XYZ Data and Reset Point Labels at the same time | ||
+ | *Fix - Synchronize Reversed XYZ Data in STEP and LASER | ||
+ | *New - Import the EL Premier TOOL setup to VTube-LASER Bender Setup | ||
+ | <td> | ||
+ | [[image:vtl_v2.9.16_ReverseXYZandLabels.png|200px|link=VTube-LASER v2.9.16]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr> | ||
+ | <td width="150">October 8, 2018</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.15]]</td> | ||
+ | <td width="250"> | ||
+ | *New - END LENGTH FILTER shifts length corrections between A-End and B-End | ||
+ | *Fix - Important fix for importing and measuring 180-degree bends | ||
+ | *New - The SUPRAVISION BATCH IMPORT now uses the default project setup to build VTube project files | ||
+ | *New - VTube-STEP now imports Autodesk Inventor tube XYZ files | ||
+ | *Fix - "Reset Point Labels" issue | ||
+ | <td> | ||
+ | [[image:vtl_v2.9.15_EndLengthFilter_Graphic.png|200px|link=VTube-LASER v2.9.15]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ==== [[image:Gears_view_small.png]] VTube-LASER - Third Quarter - 2018==== | ||
+ | |||
+ | |||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr> | ||
+ | <td width="150">August 29, 2018</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.14]]</td> | ||
+ | <td width="250"> | ||
+ | * New - VTube is now compatible with the new FARO 8-Axis Driver released in August, 2018 | ||
+ | * New - VTube now allows you to use FRACTION values for floating point numbers in Part Setup, XYZ Grid, and LRA Grid | ||
+ | * New - VTube can now report absolute style CONRAC bender corrections | ||
+ | * Fixed - Clearing all Cut Planes from the Cut Plane List Now Works | ||
+ | * New - RONIKolli7 Bender Simulator ASCII XYZ file import | ||
+ | <td> | ||
+ | [[image:vtl_v2.9.14_fractions.png|200px|link=VTube-LASER v2.9.14]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr> | ||
+ | <td width="150">August 16, 2018</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.12]]</td> | ||
+ | <td width="250"> | ||
+ | * New - NOTE LIST in Part Setup for an unlimited number of notes per project | ||
+ | * New - LRA popup menu command splits a bend into two adjacent bends | ||
+ | * New - Minimum Clamp Length Filter for Corrections | ||
+ | * Fix - Export selection mode now works properly | ||
+ | * Fix - The RECALL button now enables for the appropriate bender protocols. | ||
+ | |||
+ | <td> | ||
+ | [[image:vtl_v2.9.12_splitbend_into_twobends_vertical.png|200px|link=VTube-LASER v2.9.12]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr> | ||
+ | <td width="150">July 30, 2018</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.11]]</td> | ||
+ | <td width="250"> | ||
+ | * New - Enhanced Laser Scan Logic for Rectangular and Square Tubes | ||
+ | * Fix - Rectangular Probe Compensation Offset Direction Logic Corrected | ||
+ | * New - Split Bends rows are now highlighted yellow in the LRA grids. | ||
+ | * Fix - We discovered issues with and fixed Absolute LENGTH data (MIL-D-9898C) calculations for Split Bends. | ||
+ | * New - STAR TECHNOLOGY Bender Corrections Through a Network | ||
+ | * New - (New Value) Maximum point per stripe for END SCANS makes graphics redraw faster | ||
+ | * Fix - Bender Setup Window Display on Reduced Monitor Count | ||
+ | * Fix - End Length Deviations in Tube Data Storage | ||
+ | <td> | ||
+ | [[image:vtl_v2.9.11_rectangular_laser_scan_image.png|200px|link=VTube-LASER v2.9.11]]<br><br> | ||
+ | [[image:StarEvoSplash.png|200px|link=VTube-LASER v2.9.11]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr> | ||
+ | <td width="150">July 5, 2018</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.10]]</td> | ||
+ | <td width="250"> | ||
+ | * New LASER FILTER- Minimum Point Count setting for LASER stripes reduces outliers | ||
+ | * New - "LASER SCAN DATA" FILTER sound indicates when all scanned data is removed by the filters or the scanner is out of range | ||
+ | * New - Press the accept button without needing to aim at the part | ||
+ | * New - HERBER NEW PART setup | ||
+ | * New - HERBER CORRECTIONS | ||
+ | * New - VTube-LASER tuned to handle the new FARO 6.1.2.7 driver | ||
+ | * New - Minor fixes | ||
+ | <td> | ||
+ | [[image:vtl_v2.9.10._laserscanfilter_sound.png|200px|link=VTube-LASER v2.9.10]]<br><br> | ||
+ | [[image:HerberSplash.png|200px|link=VTube-LASER v2.9.10]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ==== [[image:Gears_view_small.png]] VTube-LASER - Second Quarter - 2018==== | ||
+ | |||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr> | ||
+ | <td width="150">June 15, 2018</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.9]]</td> | ||
+ | <td width="250"> | ||
+ | * New - SCP (Stripe Cut Plane) measure feature removes entire stripes that are out of range based on the front diameter. (VTube-LASER mode) | ||
+ | * New - Viewport change now connects laser stripes with thick lines for much easier viewing of stripe data. (VTube-LASER mode) | ||
+ | * New - Automatic Negative Straight Fix During Parametric Rebuild (VTube-STEP mode) | ||
+ | * Fix - Tube Construction Feature now works again. (VTube-LASER mode) | ||
+ | * Fix - COLLECTION FEATURE object delete. (VTube-STEP mode) | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:VTube-LASER_v2.9.9_StripeCutPlaneWithLogo.png|200px|link=VTube-LASER v2.9.9]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr> | ||
+ | <td width="150">May 16, 2018</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.8]]</td> | ||
+ | <td width="250"> | ||
+ | * New - Restore Window screen locations at load. | ||
+ | * Fix - MTA - Measured Tube Averaging | ||
+ | * New - For bender corrections: Warn operators when correction damping is active | ||
+ | * New - Show "Split bends present" in warning header when they are present | ||
+ | * New - A-End and B-End Offset values in reports | ||
+ | * Enhanced - Split Bend calculations more robust in STEP mode | ||
+ | * New- Set Split Bend to active for each split bend imported | ||
+ | * Enhanced - Improved float window handling | ||
+ | * New - Put Part Number in the "Displayed in UI" field when importing models | ||
+ | * Enhanced - Improved internal configuration file handling | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:VTube-LASER_v2.9.8_threescreen.png|400px|link=VTube-LASER v2.9.8]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr> | ||
+ | <td width="150">April 5, 2018</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.7]]</td> | ||
+ | <td width="250"> | ||
+ | * New - Export any report to a remote path. | ||
+ | * New - Automatic offer to copy MEASURED to MASTER during reverse-engineering. | ||
+ | * Fix - Floating Window Issues Resolved | ||
+ | * New - Measured Tube Averaging (MTA) enhancements in the User Interface. | ||
+ | * New - Tube Control Window - Buttons Hide and Display Based on Context | ||
+ | * New - "Radius Zero Found" warning | ||
+ | * New - Tube Inspection Report that mimics the old Supravision report | ||
+ | * Fix - Collected Items Selection and Delete | ||
+ | * New - Japanese language file update | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:VTube-LASER-V2.9.7_ExportHTMLReportToPath.png|400px|link=VTube-LASER v2.9.7]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ==== [[image:Gears_view_small.png]] VTube-LASER - First Quarter - 2018==== | ||
+ | |||
+ | |||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr> | ||
+ | <td width="150">March 13, 2018</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.6]]</td> | ||
+ | <td width="250"> | ||
+ | * New AB Length tolerances and color-coded reporting | ||
+ | * New Optional out-of-tolerance text in reports like older Supravision reports | ||
+ | * New go directly to report print button | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:VTL Single Tube with shadow.png|400px|link=VTube-LASER v2.9.5]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr> | ||
+ | <td width="150">March 2, 2018</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.5]]</td> | ||
+ | <td width="250"> | ||
+ | * Faster User Interface | ||
+ | * Fixed Solid Model image print in reports | ||
+ | * New Separate Perspective Mode for LASER | ||
+ | * New Request Reverse Calc when leaving LRA grids | ||
+ | * Repaired Reverse Calc Orientation Issue | ||
+ | * Fixed build to SOLIDWORKS feature for assemblies | ||
+ | * New DENGLER VDS Import | ||
+ | * New DENGLER VDS Output | ||
+ | * New BEND-TECH BTTX 7x Import | ||
+ | * New Minimum Clamp Length Value | ||
+ | * New "Length less than clamp" warning | ||
+ | * New "Zero-degree bend" angle warning | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:VTL Single Tube with shadow.png|400px|link=VTube-LASER v2.9.5]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr> | ||
+ | <td width="150">February 14, 2018</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.4]]</td> | ||
+ | <td width="250"> | ||
+ | '''NEW in 2.9.4:''' <br><br> | ||
+ | # '''MICROSCRIBE''' Fix for ball diameter value setting | ||
+ | # '''UI improvements''' | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:vtube-laser_v2.9_assembly_screen_logo.png|400px|link=VTube-LASER v2.9.4]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | <table cellpading=10> | ||
+ | <tr> | ||
+ | <td width="150">February 4, 2018</td> | ||
+ | <td width="150">[[VTube-LASER v2.9.3]]</td> | ||
+ | <td width="250"> | ||
+ | '''NEW in 2.9.3:''' <br><br> | ||
+ | # '''MTA''' (Measured Tube Averaging) for super accurate measures | ||
+ | # '''WAFIOS''' Bender Correction | ||
+ | # '''NUMALLIANCE''' Bender Correction | ||
+ | # '''DENGLER''' Bender Correction | ||
+ | # '''MICROSCRIBE''' arm connection | ||
+ | # '''ASSEMBLY''' build to SOLIDWORKS | ||
+ | # '''CHIYODA EX''' CHS File IMPORT | ||
+ | # Several UI improvements | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:MTA Banner.png|400px|link=VTube-LASER v2.9.3]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
==== [[image:Gears_view_small.png]] VTube-LASER - Fourth Quarter - 2017==== | ==== [[image:Gears_view_small.png]] VTube-LASER - Fourth Quarter - 2017==== | ||
Line 24: | Line 449: | ||
<table cellpading=10> | <table cellpading=10> | ||
<tr> | <tr> | ||
− | <td width="150">December | + | <td width="150">December 12, 2017</td> |
<td width="150">[[VTube-LASER v2.9.2]]</td> | <td width="150">[[VTube-LASER v2.9.2]]</td> | ||
<td width="250"> | <td width="250"> | ||
− | * FIX- Repaired a bug in Split Bend and Bend Profile point cloud projections. | + | * FIX - Repaired a bug in Split Bend and Bend Profile point cloud projections. |
+ | * FIX - Rare condition issue with end trim fixed. (build 108) | ||
+ | * FIX - Bender number remembered after part measure. (build 109) | ||
</td> | </td> | ||
<td> | <td> | ||
Line 65: | Line 492: | ||
* IMPROVED - VTube-LASER loads the LASER window first at startup (rather than the VTube-STEP window). | * IMPROVED - VTube-LASER loads the LASER window first at startup (rather than the VTube-STEP window). | ||
* FIXES and ENHANCEMENTS - Z order screen fix for floating windows, faster sounds for remeasure, Guide window displays in lower right corner to avoid DRO, imported model deletion fix | * FIXES and ENHANCEMENTS - Z order screen fix for floating windows, faster sounds for remeasure, Guide window displays in lower right corner to avoid DRO, imported model deletion fix | ||
+ | * End Scan Diameter Qualification Tolerances are no longer used. | ||
</td> | </td> | ||
<td> | <td> | ||
Line 231: | Line 659: | ||
<td width="150">[[VTube-LASER v2.6]]</td> | <td width="150">[[VTube-LASER v2.6]]</td> | ||
<td width="200"> | <td width="200"> | ||
− | *NEW '''DIAMETER CUT PLANES''' This powerful feature lets you measure across several diameters at the same time on parts that twist back on themselve. VTube will select the correct diameter scan points automatically.<br><br> | + | *NEW DCP - '''DIAMETER CUT PLANES''' This powerful feature lets you measure across several diameters at the same time on parts that twist back on themselve. VTube will select the correct diameter scan points automatically.<br><br> |
*ENHANCED - '''MULTIPLE CUT PLANES''' - We've completely redesigned CUT PLANES in VTube. Create cut planes at any time, change any setting on the fly, turn cut planes on/off - even during a regular measure. | *ENHANCED - '''MULTIPLE CUT PLANES''' - We've completely redesigned CUT PLANES in VTube. Create cut planes at any time, change any setting on the fly, turn cut planes on/off - even during a regular measure. | ||
</td> | </td> |
Latest revision as of 22:07, 16 January 2021
|
VTube-LASER - Version 3 - Version Control Report
January 11, 2021 | Latest Build: 411 |
|
VTube-LASER - Third Quarter - 2020
July 15, 2020 | VTube-LASER v3 |
|
VTube-LASER - Second Quarter - 2019
June 12, 2019 | VTube-LASER v2.9.20 - Build 10 |
|
April 29, 2019 | VTube-LASER v2.9.19 - Build 16 |
|
VTube-LASER - First Quarter - 2019
March 12, 2019 | VTube-LASER v2.9.18 - Build 18 |
|
|
January 17, 2019 | VTube-LASER v2.9.17 - Build 42 |
|
VTube-LASER - Fourth Quarter - 2018
October 19, 2018 | VTube-LASER v2.9.16 |
|
October 8, 2018 | VTube-LASER v2.9.15 |
|
VTube-LASER - Third Quarter - 2018
August 29, 2018 | VTube-LASER v2.9.14 |
|
August 16, 2018 | VTube-LASER v2.9.12 |
|
July 30, 2018 | VTube-LASER v2.9.11 |
|
July 5, 2018 | VTube-LASER v2.9.10 |
|
VTube-LASER - Second Quarter - 2018
June 15, 2018 | VTube-LASER v2.9.9 |
|
May 16, 2018 | VTube-LASER v2.9.8 |
|
April 5, 2018 | VTube-LASER v2.9.7 |
|
VTube-LASER - First Quarter - 2018
March 13, 2018 | VTube-LASER v2.9.6 |
|
March 2, 2018 | VTube-LASER v2.9.5 |
|
February 14, 2018 | VTube-LASER v2.9.4 |
NEW in 2.9.4:
|
February 4, 2018 | VTube-LASER v2.9.3 |
NEW in 2.9.3:
|
VTube-LASER - Fourth Quarter - 2017
December 12, 2017 | VTube-LASER v2.9.2 |
|
November 27, 2017 | VTube-LASER v2.9.1 |
|
November 1, 2017 | VTube-LASER v2.9 |
MAJOR NEW FEATURE: ASSEMBLY
|
VTube-LASER - Third Quarter - 2017
July 26, 2017 | VTube-LASER v2.8.5 |
|
VTube-LASER - Second Quarter - 2017
June 22, 2017 | VTube-LASER v2.8.4 |
|
June 12, 2017 | VTube-LASER v2.8.3 |
|
April 11, 2017 | VTube-LASER v2.8.2 |
|
April 8, 2017 | VTube-LASER v2.8.1 |
|
April 19, 2017 | VTube-LASER v2.8 |
|
VTube-LASER - First Quarter - 2017
February 11, 2017 | VTube-LASER v2.7 |
|
VTube-LASER - Third Quarter - 2016
July 27, 2016 | VTube-LASER v2.6 |
|
|
VTube-LASER - Second Quarter - 2016
June 22, 2016 | VTube-LASER v2.5 |
|
VTube-LASER - First Quarter - 2016
March 25, 2016 | VTube-LASER v2.4 | Added new accumulated length values for reports, fixed the automatic image update in the reports window. |
February 10, 2016 | VTube-LASER v2.3 | Multi-elongation Setup for multiple elongation, Springback-compensated grids, Springback-compensation output for benders fixed, Automatic Image Refresh state storage fixed | |
January 21, 2016 | VTube-LASER v2.2 | 3X faster graphics, faster scanning for HD scanner, tube measuring averaging with Hybrid feature, many other new features added |
VTube-LASER - Second Quarter - 2015
June 12, 2015 | VTube-LASER v2.1.2 | New model import features in STEP mode, tube label fixes, DRO transparency, now handles floating point systems that use commas rather than decimal points for measuring. |
VTube-LASER - First Quarter - 2015
February 16, 2015 | VTube-LASER v2 | New VTube Path Manager, New Winton WMC Bender Data Setup Editor, other fixes and enhancements. |
VTube-LASER - Third Quarter - 2014
Novermber 25, 2014 | VTube-LASER v1.99 | "Pull arm from cradle" message removed for automatic scan modes. Added green arm connected LED lamp to Arm Utilities menu. New CSM M4 and Alpine M4 bender correction. |
November 12, 2014 | VTube-LASER v1.98 | Changes to transfer of bender adjustment values into Bender Setup menu. |
November 7, 2014 | VTube-LASER v1.97 | Two new import types are added to VTube-STEP: Laservision CSV and SolidWorks 3DSketch |
October 27, 2104 | VTube-LASER v1.96 | High density point scans draw faster on the screen. Increased maximum stripe resolution for compatibility with the v6 scanner. Critical fix for Split Bend. Point clouds draw in viewport in realtime starting in this version. Point labels are more efficient. Languages updated. |
September 1, 2014 | VTube-LASER v1.94 | Now permanently store every measured and aligned data iteration in the Tube Data Storage feature. |
July 23, 2014 | VTube-LASER v1.93 | The Default Tolerance value is moved into the Part Setup menu for convenience. |
July 15, 2014 | VTube-LASER v1.92 | New export to Eaton Leonard Laservision spreadsheet in VTube-STEP (included with VTube-LASER). Other minor fixes. |
VTube-LASER - Second Quarter - 2014
June 30, 2014 | VTube-LASER v1.91 | New Leapfrog allows arm to measure very long tubes, redesign of automatic alignment math, fixed bug in end trim distance math, new expanded inspection data grids, new +/- tolerances for XYZ intersection deviations |
April 15, 2014 | VTube-LASER v1.90 | Alpine bender - output as roll bend, fixes to minor bugs in counts on the display, saves the imported model to the project file, improved QuickLoad, Bender Data ehancements |
VTube-LASER - First Quarter - 2014
March 25, 2014 | VTube-LASER v1.89 | Fix for disappearing floating windows, LED indicates arm connected, added new sound for calc complete, multicolor Guide window depending on current viewport mode |
March 11, 2014 | VTube-LASER v1.88 | Critical fix for FARO driver change for using ball probes. Adjustment Enhancements in UniScan mode for using the ball probe. New stripe count in the DRO when using the scanner. |
February 25, 2014 | VTube-LASER v1.87 | New UniScan. New cylinder spike filter. New Quick Load window. New red button to early stop stripe scanning. Added Radius output to Winton ECNC4 communications. |
January 20, 2014 | VTube-LASER v1.86 | Addressed issues with windows disappearing on certain Dell laptops during measurement. Added AddisonMckee IV enhanced communications features. VTube now stores the bender number with the project file save. |
January 2, 2014 | VTube-LASER v1.85.1 | Optimized to be faster than previous versions, Memory leaks plugged in the Alignment feature, Benderlink setup menu enhanced, timers optimized for faster performance. Added both + and - tolerances to the end lengths, added color to XYZ intersection deviations in reports |
VTube-LASER - Third Quarter - 2013
July 29, 2013 | VTube-LASER v1.83 | Function shortcut keys, new right side menus are grid-based, can collapse, can change font sizes, can change widths, Bender Setup menu tracks last date/time of communications in both directions, TubeCalc elongation converter, Supravision export repaired, much more... |
VTube-LASER - Second Quarter - 2013
June 19, 2013 | VTube-LASER v1.82 | Measure rectangular tube, automatic build to SolidWorks |
April 19, 2013 | VTube-LASER v1.81.6 | New FARO arm utilities menu. |
April 2, 2013 | VTube-LASER v1.81.5 | New features added to the Language Editor, fix to Point Label Balloons |
VTube-LASER - First Quarter - 2013
March 28, 2013 | VTube-LASER v1.81.4 | MANY new features - like balloon point labels, new reports, new copy/paste grids, new copy model to clipboard as bitmap |
February 22, 2013 | VTube-LASER v1.81.3 | New UNDO feature. Moved configuration files to a new location to make multiple-user installations simpler. |
Unreleased | VTube-LASER v1.81.1 | Enhanced Transfluid communication protocol. Adjusted Ribbon calculation output. |
January 8, 2013 | VTube-LASER v1.81 | New Winton ECNC 4 protocol for bender correction, new transform centerline so that any bend is true, new separate templates for STEP and LASER modes. |
VTube-LASER - Fourth Quarter - 2012
November 26, 2012 | VTube-LASER v1.80.1 | Resolved grid text header draw issue, silenced error when now sound drivers present |
November 20, 2012 | VTube-LASER v1.80 | New centerline TRANSFORMATION feature - make any bend true with the radius value centered. Fixed an end trim bug for one bend parts. |
November 9, 2012 | VTube-LASER v1.79 | New export to CAM2 Measure 10 - either MASTER or MEASURED. New radius table in XYZ popup grid for storing often used radii - both nominal and true (undercut), and more |
October 3, 2012 | VTube-LASER v1.78 | New "Supplier" field in Part Setup. New pop-up menu features - set 0,0,0 in any row, and mirror image the part. New output master LRA with springback to Supravision file. New report with springback in master LRA data. |
VTube-LASER - Third Quarter - 2012
August 28, 2012 | VTube-LASER v1.77.4.4 | Updated Chinese for v1.77 |
August 20, 2012 | VTube-LASER v1.77.4.3 | Minor revision: Works better with foreign date/times. |
August 14, 2012 | VTube-LASER v1.77.4 | Serious enhancement in Automatic Weighting in Best Fit. Recent Project File List. New "Save" - not just "Save As...". Floating Pulldown menus. |
August 8, 2012 | VTube-LASER v1.77.3 | Material now changes length with new End Adjustment Length Values, brand new orientation control with axis images, repaired cut length calculation. |
August 4, 2012 | VTube-LASER v1.77.2 | Fine-tune Cut Plane model display |
August 3, 2012 | VTube-LASER v1.77.1 | Allows the Cut Plane model display to be switched off. |
August 1, 2012 | VTube-LASER v1.77 | HUGE UPDATE - Automatic weighting during Best Fit alignment, Hard Point alignment, new Part Setup fields, Chinese translation, new STEP interface for inputs, new damping in report, new Polar calculator... |
VTube-LASER - First Quarter - 2012
March 31, 2012 | VTube-LASER v1.76.3 | Automatic Damping Correction feature prevents overcorrection | |
March 15, 2012 | VTube-LASER v1.76 | Coping layout feature | |
February 9, 2012 | VTube-LASER v1.75.4 | Merge bends feature | |
February 7, 2012 | VTube-LASER v1.75.3 | Automatic Closeup of Last Measure feature. | |
February 2, 2012 | VTube-LASER v1.75.1 | Page numbers are added to bottom of report. Fix to move to previous when remeasure. | |
January 15, 2012 | VTube-LASER v1.75 | Scanner setup save to project is enhanced. The cylinder fit tolerance qualification is enhanced for better measuring experience. New cylinder fit error checks are added to assure good measurements. | |
January 5, 2012 | VTube-LASER v1.74 | Scanner setup is now saved with the project file. It is now possible to skip either end measurement. The end-scan qualification logic is improved. |
VTube-LASER - Fourth Quarter - 2011
October 19, 2011 | VTube-LASER v1.73 | Fine tuning for FARO Edge arm. The Cut Plane offset value is now displayed in interface. Cut Plane offset is now adjustable without remeasure. Sounds trimmed so that they play for shorter times. | |
October 10, 2011 | VTube-LASER v1.72 | Deep scanning with up to 200 stripes per straight now allowed. | |
October 4, 2011 | VTube-LASER v1.71 | New transparent envelope models. |
VTube-LASER - Third Quarter - 2011
September 20, 2011 | VTube-LASER v1.70 | Enhanced the accuracy of inspection mathematics in special situations. | |
September 1, 2011 | VTube-LASER v1.69 | Enhanced Measure Setup menu links to more Faro menus. New report values show arm and probe values like calibration dates, 2 sigma values. VTube-LASER Programmer license mode. | |
August 8, 2011 | VTube-LASER v1.68 | New Excel report builder, revised Overbend calculator, new options in the Bender Setup screen, new tab menus in Master data. | |
July 18, 2011 | VTube-LASER v1.67 | New Split Bend for precisely splitting angles that approach and exceed 180 degrees. New connect and disconnect from the arm. |
VTube-LASER - Second Quarter - 2011
May 27, 2011 | VTube-LASER v1.66 | New save changes dialog, in-process bend angle correction | |
May 19, 2011 | VTube-LASER v1.65 | Increased the accuracy of the radius stripe scan method for measuring bend radii, enhanced the Winton bender protocol, added invert rotation check boxes to the bender setup page, added new report charts | |
May 10, 2011 | VTube-LASER v1.64b | Added Transfluid bender communications, added new radius stripe scan method for measuring bend radii | |
April 6, 2011 | VTube-LASER v1.63d | Resolved issue with end-scan qualification with ball probe |
VTube-LASER - First Quarter - 2011
March 31, 2011 | VTube-LASER v1.63 | Choose from multiple custom reports on the screen. Add and edit custom report templates to VTube-LASER. | |
March 11, 2011 | VTube-LASER v1.62 | End scan qualifications are much faster, new progress dialog for when end-scan is taking more time with new process cancel button | |
March 04, 2011 | VTube-LASER v1.61 | New end labels identify the ends of the tube and automatic diameter handling fixes | |
February 21, 2011 | VTube-LASER v1.6 | Important end-scan outlier point detection and prevention, continuous tactile scan, faster redraws, improved user interface | |
February 7, 2011 | VTube-LASER v1.59 | Ball probe measurements and laser measurements now work properly together in the same tube measure. | |
January 18, 2011 | VTube-LASER v1.58 | New "Construct Tube" feature that allows users to route a tube in 3D space by pointing the arm, increase or decrease points and straights on the fly when measuring tubes | |
January 13, 2011 | VTube-LASER v1.57 | Supravision Import, faster alignment, improved Bender Setup, many other changes | |
January 6, 2011 | VTube-LASER v1.56 | New springback compensation variables, new items in the inspection report - like the new XYZ deviation report, bender data setup menu enhanced, invert rotation feature | |
January 3, 2011 | VTube-LASER v1.55 | New enhanced radius measurement |
VTube-LASER - Fourth Quarter - 2010
December 25, 2010 | VTube-LASER v1.54 | New DRO (digital readout), realtime intersection points, other enhancements |
Other Pages