Difference between revisions of "VTube-LASER Near Pass Deviation"
From ATTWiki
(→How it is used in VTube-LASER) |
|||
(15 intermediate revisions by one user not shown) | |||
Line 1: | Line 1: | ||
− | |||
<table> | <table> | ||
− | <tr> | + | <tr cellpadding=10> |
+ | <td width=225> | ||
+ | * Back to [[VTube-STEP]] | ||
+ | * Back to [[VTube-LASER]] | ||
+ | </td> | ||
<td width=300> | <td width=300> | ||
+ | [[image:vtube-laser_logo_1.96.png|200px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | __NOTOC__ | ||
+ | |||
+ | |||
+ | |||
+ | ===About Near Pass Deviation=== | ||
+ | <table> | ||
+ | <tr> | ||
+ | <td width=300 valign=top> | ||
The point at which two 3D lines are the closest to each other is where they come closest to intersecting. The distance is the “nearest pass.” | The point at which two 3D lines are the closest to each other is where they come closest to intersecting. The distance is the “nearest pass.” | ||
</td> | </td> | ||
<td> | <td> | ||
− | [[image:vtl_nearest_pass_illustration.png| | + | [[image:vtl_nearest_pass_illustration.png|500px]] |
</td> | </td> | ||
</tr> | </tr> | ||
Line 12: | Line 28: | ||
===How it is used in VTube-LASER=== | ===How it is used in VTube-LASER=== | ||
− | <table | + | <table> |
<tr> | <tr> | ||
− | <td width=300> | + | <td width=300 valign=top> |
VTube-LASER checks for and displays the Nearest Pass value when measuring two intersecting tube straights. If the value is too high, then VTube-LASER will ask you to remeasure the tube until the value is within tolerance. The default tolerance for Nearest Pass is 2mm. | VTube-LASER checks for and displays the Nearest Pass value when measuring two intersecting tube straights. If the value is too high, then VTube-LASER will ask you to remeasure the tube until the value is within tolerance. The default tolerance for Nearest Pass is 2mm. | ||
</td> | </td> | ||
Line 21: | Line 37: | ||
</td> | </td> | ||
</tr> | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | ===How To Change the Tolerance=== | ||
+ | <table> | ||
+ | <tr> | ||
+ | <td width=300 valign=top> | ||
+ | You can change the tolerance by entering System Options, Measure 1 menu and changing the Maximum Near Pass Deviation Allowed value.<br><br> | ||
+ | This value is saved uniquely for each project. | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:vtl_systemoptions_button.png|600px]]<br> | ||
+ | [[image:vtl_nearest_pass_max_deviation2.png|600px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td width=300 valign=top> | ||
+ | You can change the tolerance when measuring by pressing the gear button at the top of the Cylinder Fit Data window. | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:vtl_cylinderfitdata_gearbutton.png|600px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
</table> | </table> | ||
==Other== | ==Other== | ||
See [[DCF - Dual Cylinder Fit]] | See [[DCF - Dual Cylinder Fit]] |
Latest revision as of 13:58, 29 June 2022
|
About Near Pass Deviation
The point at which two 3D lines are the closest to each other is where they come closest to intersecting. The distance is the “nearest pass.” |
How it is used in VTube-LASER
VTube-LASER checks for and displays the Nearest Pass value when measuring two intersecting tube straights. If the value is too high, then VTube-LASER will ask you to remeasure the tube until the value is within tolerance. The default tolerance for Nearest Pass is 2mm. |
How To Change the Tolerance
You can change the tolerance by entering System Options, Measure 1 menu and changing the Maximum Near Pass Deviation Allowed value. |
|
You can change the tolerance when measuring by pressing the gear button at the top of the Cylinder Fit Data window. |