Difference between revisions of "VTube-LASER v1.54"
(37 intermediate revisions by one user not shown) | |||
Line 1: | Line 1: | ||
<table> | <table> | ||
<tr cellpadding=10> | <tr cellpadding=10> | ||
− | <td width= | + | <td width=225> |
− | [[image:vtube-laser_logo.jpg| | + | [[image:vtube-laser_logo.jpg|200px]] |
− | [[ | + | ==Revision 1.54== |
+ | Back to [[VTube-LASER]] | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
+ | [[image:vtube-laser_screen_1_54.jpg|300px]] | ||
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
__NOTOC__ | __NOTOC__ | ||
Line 18: | Line 19: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
− | The digital readout was added to give feedback for the arm motion | + | The digital readout was added to give feedback for the arm motion and arm diagnostics.<br><br> |
+ | [[image:vtube-laser_dro.jpg|150px]] | ||
</td> | </td> | ||
<td> | <td> | ||
[[image:vtube-laser_dro_closeup.jpg|300px]]<br> | [[image:vtube-laser_dro_closeup.jpg|300px]]<br> | ||
− | |||
</td> | </td> | ||
</tr> | </tr> | ||
Line 38: | Line 39: | ||
<td> | <td> | ||
[[image:vtube-laser_viewcontrol.jpg]] | [[image:vtube-laser_viewcontrol.jpg]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED - Automatic Clear Measure Process After End B Measure === | ||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | Now the Measure Tube process automatically clears from the screen after the data from End B is collected<br><br> | ||
+ | This causes the tube measure control to close automatically. | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:vtube-laser_tubemeasurecontrol_endb.jpg|300px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW - Realtime Calculation of Intersection === | ||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | Intersection points are calculated in realtime and displayed on the screen as orange points. | ||
+ | <br><br> | ||
+ | This means that they are calculated as soon as possible during the measurement. This helps make the MOVE command and other commands that rely on realtime information possible. | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:vtube-laser_intersectionpoints.jpg|300px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW - Realtime Calculation of Intersection Error === | ||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | Each point is checked for a Maximum Intersection Error which is set in the Measuring 2 tab of the System Options menu. The default tolerance is 2mm, or 0.078 inches. | ||
+ | <br><br> | ||
+ | If an intersection error calculates beyond the tolerance, then VTube stops and warns the operator of a potential problem, then allows him to remeasure or continue to the next straight. | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:vtube-laser_intersection_error_idialog.jpg|300px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW - Code Signing of VTube.exe === | ||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | The VTube program is now code signed in order to comply with the Microsoft Authenticode requirements. | ||
+ | <br><br> | ||
+ | *Ensures authenticity - users that they know where the code came from | ||
+ | *Ensures integrity - verifies that code has not been tampered with since publication | ||
+ | *Reduces error messages and security warnings on download and installation on Windows Vista and Windows 7 computers | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:vtube-laser_codesigned.jpg|300px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW - Verified Bluetooth Compatible === | ||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | VTube-LASER is verified to work with the FARO ScanArm Bluetooth connection. This allows connection to the FARO arms within 30 feet of the VTube-LASER computer without cables. | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:vtube-laser_bluetooth.jpg|300px]]<br> | ||
+ | [[image:vtube-laser_systemtray_bluetooth.jpg|300px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED - VTube-LASER Setup Files Include the FARO USB Setups === | ||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | The VTube-LASER installation setup now includes the FARO USB drivers for either 32 or 64 bit computers.</td> | ||
+ | <td> | ||
+ | [[image:usb_connector.jpg|300px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW - PDF Printer Driver Setup Included in Installation === | ||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | |||
+ | <td width=200> | ||
+ | Now every VTube-LASER installation can also install a PDF printer driver for easy output of inspection reports in the PDF format. This lets operators create historical fixed reports with static date/time for a record of qualification of the tube shape. | ||
+ | <br><br> | ||
+ | The two programs installed are the CutePDF Writer printer driver and the GPL Ghostscript program - which is required by the CutePDF Writer print driver to operate. | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:gpl_ghostscript_installation.jpg|300px]]<br> | ||
+ | [[image:cute_pdf_installation.jpg|300px]] | ||
</td> | </td> | ||
</tr> | </tr> |
Latest revision as of 23:40, 28 December 2010
Revision 1.54Back to VTube-LASER |
NEW - DRO: Digital Readout
The digital readout was added to give feedback for the arm motion and arm diagnostics. |
ENHANCED - Arm as Mouse Feature
The automatic "arm as a mouse" feature is enhanced so that the arm can be used as a mouse whenever a dialog displays on the screen - even in the middle of tube measurement. As soon as the dialog closes and measuring resumes, the arm as a mouse feature switches off.
|
ENHANCED - Automatic Clear Measure Process After End B Measure
Now the Measure Tube process automatically clears from the screen after the data from End B is collected |
NEW - Realtime Calculation of Intersection
Intersection points are calculated in realtime and displayed on the screen as orange points.
|
NEW - Realtime Calculation of Intersection Error
Each point is checked for a Maximum Intersection Error which is set in the Measuring 2 tab of the System Options menu. The default tolerance is 2mm, or 0.078 inches.
|
NEW - Code Signing of VTube.exe
The VTube program is now code signed in order to comply with the Microsoft Authenticode requirements.
|
NEW - Verified Bluetooth Compatible
VTube-LASER is verified to work with the FARO ScanArm Bluetooth connection. This allows connection to the FARO arms within 30 feet of the VTube-LASER computer without cables. |
ENHANCED - VTube-LASER Setup Files Include the FARO USB Setups
The VTube-LASER installation setup now includes the FARO USB drivers for either 32 or 64 bit computers. |
NEW - PDF Printer Driver Setup Included in Installation
Now every VTube-LASER installation can also install a PDF printer driver for easy output of inspection reports in the PDF format. This lets operators create historical fixed reports with static date/time for a record of qualification of the tube shape.
|
Other Pages
- Back to VTube-LASER