Difference between revisions of "VTube-LASER v1.55"

From ATTWiki
Jump to: navigation, search
(25px ENHANCED - VTube-LASER Setup Files Include the FARO USB Setups)
(25px FIX - Measure Tube XYZ Data Build)
 
(7 intermediate revisions by one user not shown)
Line 21: Line 21:
 
Since radius sections are often highly distorted with ovality and changing radius values along the bend, this new radius scan-segment measurement method allows for more accurate averaging of radius measurement for reverse-engineering of radius values by allowing users to scan as many as 10 arc segments if necessary for better averaging of radius values.
 
Since radius sections are often highly distorted with ovality and changing radius values along the bend, this new radius scan-segment measurement method allows for more accurate averaging of radius measurement for reverse-engineering of radius values by allowing users to scan as many as 10 arc segments if necessary for better averaging of radius values.
 
<br><br>
 
<br><br>
The Set Segment Scan Count box (see below) allows you to enter from 3 to 10 segments to measure per arc.
+
The new Set Segment Scan Count box allows you to enter from 3 to 10 segments to measure per arc. (Also see the enhanced Measure Process menu below.)
 
<br><br>
 
<br><br>
  
Line 60: Line 60:
 
</tr>
 
</tr>
 
</table>
 
</table>
<br><br>
 
  
  
 +
===[[image:Check.jpg|25px]] FIX - Measure Tube XYZ Data Build  ===
  
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=200>
 +
This version fixes a bug found in version 1.54 where the Measured XYZ data may not update after a measure.<br><br>
  
 +
Please be sure to use this version rather than v1.54.
 +
<br><br>
 +
</td>
 +
<td>
 +
</td>
 +
</tr>
 +
</table>
  
 
+
===[[image:Check.jpg|25px]] ENHANCED - Best Fit Alignment Mathematics ===
 
+
 
+
 
+
 
+
 
+
===[[image:Check.jpg|25px]] NEW - PDF Printer Driver Setup Included in Installation ===
+
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
 
<td width=200>
 
<td width=200>
Now every VTube-LASER installation can also install a PDF printer driver for easy output of inspection reports in the PDF format.  This lets operators create historical fixed reports with static date/time for a record of qualification of the tube shape.
+
New features were added to prevent unnecessary errors/warnings from displaying for parts that align too closely with the master part.
 
<br><br>
 
<br><br>
The two programs installed are the CutePDF Writer printer driver and the GPL Ghostscript program - which is required by the CutePDF Writer print driver to operate.
 
 
</td>
 
</td>
 
<td>
 
<td>
[[image:gpl_ghostscript_installation.jpg|300px]]<br>
 
[[image:cute_pdf_installation.jpg|300px]]
 
 
</td>
 
</td>
 
</tr>
 
</tr>

Latest revision as of 02:53, 5 January 2011

Vtube-laser logo.jpg

Revision 1.55

Back to VTube-LASER

Vtube-laser screen 1 54.jpg


Check.jpg NEW: Radius Segment Scan Method

Since radius sections are often highly distorted with ovality and changing radius values along the bend, this new radius scan-segment measurement method allows for more accurate averaging of radius measurement for reverse-engineering of radius values by allowing users to scan as many as 10 arc segments if necessary for better averaging of radius values.

The new Set Segment Scan Count box allows you to enter from 3 to 10 segments to measure per arc. (Also see the enhanced Measure Process menu below.)

Vtube-laser radius segment measurement graphic.jpg

Vtube-laser radius segment scan count.jpg

Check.jpg ENHANCED - Measure Process Menu

The enhanced Measure Process menu is reorganized. The menu includes the new Straight Count box - which was moved from the Measure Setup menu.

The menu also includes a new field for the new Radius Segment Scan - segment count.

Vtube-laser measureprocess v1 55.jpg



Check.jpg ENHANCED - Measure Setup Menu

The Measure Setup program is condensed because the Straight Count setting has been moved to the Measure Process menu for consistency.

Vtube-laser measuresetup v1 55.jpg


Check.jpg FIX - Measure Tube XYZ Data Build

This version fixes a bug found in version 1.54 where the Measured XYZ data may not update after a measure.

Please be sure to use this version rather than v1.54.

Check.jpg ENHANCED - Best Fit Alignment Mathematics

New features were added to prevent unnecessary errors/warnings from displaying for parts that align too closely with the master part.

Other Pages