Difference between revisions of "VTube-LASER v1.62"
(14 intermediate revisions by one user not shown) | |||
Line 7: | Line 7: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | [[image:vtube- | + | [[image:vtube-laser_1_62.jpg|300px]] |
</td> | </td> | ||
</tr> | </tr> | ||
Line 15: | Line 15: | ||
− | ===[[image:Check.jpg|25px]] ENHANCED: End Scans Faster=== | + | ===[[image:Check.jpg|25px]] ENHANCED: End Scans Faster + New Progress Window=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
− | Analysis of end scans is now | + | Analysis of end scans is now at least twice as fast as in version 1.61. |
<br><br> | <br><br> | ||
When end-scans are taking more time than a few seconds, a progress window will display.<br><br> | When end-scans are taking more time than a few seconds, a progress window will display.<br><br> | ||
Line 31: | Line 31: | ||
<br><br> | <br><br> | ||
− | ===[[image:Check.jpg|25px]] | + | ===[[image:Check.jpg|25px]] NEW: Scan Rate Types: Timer or Distance=== |
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | Now all scan rates are determined by either a TIMER or a DISTANCE. | ||
+ | <br><br> | ||
+ | For end-scans, use a timer and set the timer value to 0 milliseconds.<br><br> | ||
+ | For cylinder scans, you can use DISTANCE and set the Cylinder Scan Distance to whatever value is convenient for separation. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-laser_measuresetup_scanrates.jpg|300px]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Multiple Point Qualification End Scan=== | ||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
+ | <td width=200> | ||
+ | VTube-LASER now uses multiple points to qualify the end-scan. This gives it better protection against outlier points.<br><br> | ||
+ | A new End-Scan Fit window gives information about how many points were used in the end-trim, and the span of all the point positions. Higher point counts with lower spans indicate a better data set for end-trim. | ||
+ | </td> | ||
<td width=300> | <td width=300> | ||
− | + | [[image:vtube-laser_endscan_fitwindow.jpg|300px]]<br><br> | |
− | < | + | |
</td> | </td> | ||
</tr> | </tr> | ||
Line 44: | Line 63: | ||
<br><br> | <br><br> | ||
+ | ===[[image:Check.jpg|25px]] REPAIR: Diameter and Wall Detection for STEP Mode=== | ||
+ | |||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | See [[VTube-STEP v1.62]] for details.</td> | ||
+ | <td width=30> | ||
+ | [[image:Vtube-step_1_62.jpg|300px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
===[[image:Check.jpg|25px]] Other Changes === | ===[[image:Check.jpg|25px]] Other Changes === | ||
Line 49: | Line 81: | ||
<tr> | <tr> | ||
<td width=300> | <td width=300> | ||
+ | * The A End and B End OFFSETs other than ZERO caused a problem where end-scans would never be qualified. This has been resolved in this version. | ||
</td> | </td> | ||
<td> | <td> | ||
Line 57: | Line 90: | ||
<br><br> | <br><br> | ||
− | ===[[image:Check.jpg|25px]] Issues with this version fixed in | + | ===[[image:Check.jpg|25px]] Issues with this version fixed in newer versions=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=500> | <td width=500> | ||
− | * | + | *Diameter measures now use the Cylinder scan rate filter setup values. (Fixed in [[VTube-LASER v1.63]])<br><br> |
+ | </td> | ||
<td width=300> | <td width=300> | ||
</td> | </td> | ||
Line 70: | Line 104: | ||
=Other Pages= | =Other Pages= | ||
*Back to [[VTube-LASER]] | *Back to [[VTube-LASER]] | ||
+ | |||
+ | <table> | ||
+ | <tr> | ||
+ | <td width="400"> | ||
+ | [http://www.youtube.com/watch?v=HblLf0BpNgk VTube-LASER Training Video] - How to perform effective end scans. | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:vtube-laser_effective_end_scan_video_b.jpg|300px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> |
Latest revision as of 16:54, 1 April 2011
Revision 1.62Back to VTube-LASER |
ENHANCED: End Scans Faster + New Progress Window
Analysis of end scans is now at least twice as fast as in version 1.61.
|
NEW: Scan Rate Types: Timer or Distance
Now all scan rates are determined by either a TIMER or a DISTANCE.
|
NEW: Multiple Point Qualification End Scan
VTube-LASER now uses multiple points to qualify the end-scan. This gives it better protection against outlier points. |
REPAIR: Diameter and Wall Detection for STEP Mode
See VTube-STEP v1.62 for details. |
Other Changes
|
Issues with this version fixed in newer versions
|
Other Pages
- Back to VTube-LASER
VTube-LASER Training Video - How to perform effective end scans. |