− | + | [[image:cncbender_logo.jpg|400px]] | |
− | To switch the Master Power on, clear all the E-stops and safety mechanisms, then press the Master Power On button. | + | Master Power On is the state in which all of the safety stops (E-stops) are cleared and the bender pump is switched on. To switch the Master Power on, clear all the E-stops and safety mechanisms, then press the Master Power On button. In this state, the Master Power On button will illuminate green. If an E-stop, safety mat, or bend-arm safety plate is tripped, then the electronics in the bender will switch the Master Power OFF. |
− | + | ||
− | In this state, the Master Power On button will illuminate green. | + | |
− | + | ||
− | If an E-stop, safety mat, or bend-arm safety plate is tripped, then the electronics in the bender will switch the Master Power OFF. | + | |
See also: [[Can Master Power Be Kept ON by CNC Bender?]] | See also: [[Can Master Power Be Kept ON by CNC Bender?]] |
Latest revision as of 23:36, 20 September 2007
Master Power On is the state in which all of the safety stops (E-stops) are cleared and the bender pump is switched on. To switch the Master Power on, clear all the E-stops and safety mechanisms, then press the Master Power On button. In this state, the Master Power On button will illuminate green. If an E-stop, safety mat, or bend-arm safety plate is tripped, then the electronics in the bender will switch the Master Power OFF.
See also: Can Master Power Be Kept ON by CNC Bender?