Difference between revisions of "VTube-LASER v1.65"
(→Revision 1.65) |
|||
(37 intermediate revisions by one user not shown) | |||
Line 7: | Line 7: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | [[image:vtube- | + | [[image:vtube-laser_screen_1_65.jpg|300px]] |
</td> | </td> | ||
</tr> | </tr> | ||
Line 14: | Line 14: | ||
__NOTOC__ | __NOTOC__ | ||
− | + | ===[[image:Check.jpg|25px]] NEW: Radius Correction for Push-Bending=== | |
− | ===[[image:Check.jpg|25px]] NEW: | + | [[image:vtube-laser_1_65_radiuscorrection.jpg|425px]]<br><br> |
− | [[image:vtube- | + | |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
− | VTube-LASER | + | The radius correction menu allows VTube-LASER to correct push-bends on Unison Limited benders.<br><br> |
+ | The menu will send data directly to any bender that can read our radius transfer files. The menu can be accessed from the Radius Stripe Scan menu. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-laser_1_65_radiusstripescan_sendradius.jpg|200px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
<br><br> | <br><br> | ||
− | + | ||
+ | ===[[image:Check.jpg|25px]] NEW: Bender Setup Changes=== | ||
+ | [[image:vtube-laser_1_65_benderdata.jpg|500px]]<br><br> | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | The Bender Setup window has a new easier-to-view color scheme.<br><br> | ||
+ | * ORANGE Columns are NEW ADJUSTED data to be sent out to the bender.<br> | ||
+ | * BLUE Columns contain the current bender setup before adjustment. | ||
+ | |||
+ | The bend setup grid has a new column for inverting rotations that are sent out to the bender. This allows for sending the rotation the opposite direction - then remembering the inversion for next time the project is run. | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
+ | [[image:vtube-laser_1_65_invertrotations.jpg|300px]] | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 31: | Line 50: | ||
<br><br> | <br><br> | ||
− | ===[[image:Check.jpg|25px]] ENHANCED: New Torus-fit | + | ===[[image:Check.jpg|25px]] ENHANCED: New Torus-fit Engine for Radius Stripe Scanning=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
The new radius stripe scanning method is more accurate as of this version of VTube due to a new torus-fit engine included in VTube. | The new radius stripe scanning method is more accurate as of this version of VTube due to a new torus-fit engine included in VTube. | ||
+ | <br><br> | ||
+ | [[image:vtube-laser_1_65_radiusstripescan.jpg|200px]] | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
Line 45: | Line 66: | ||
<br><br> | <br><br> | ||
− | ===[[image:Check.jpg|25px]] | + | ===[[image:Check.jpg|25px]] NEW: Bender Data + Corrections Data Chart in Reports=== |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
− | * | + | A new bender chart was added to the report template to include the bender data + corrections chart |
+ | </td> | ||
+ | <td width=300> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | [[image:vtube-laser_1_65_benderpluscorrections.jpg|500px]] | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: Report Preview Menu=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | The Report Preview menu now allows you to change the printer and the paper orientation before printing. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | [[image:vtube-laser_1_65_reportpreview.jpg|400px]] | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: Measure Setup - Laser Probe Grid=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | The Laser probe grid now has a separate checkbox for automatically enabling either laser or tactile measuring for radius stripe scans. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | [[image:vtube-laser_1_65_radiusstripescansuselaser.jpg|300px]] | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: Measure Setup - Scan Rate Grid=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=200> | ||
+ | The Scan Rate grid now has a separate controls for radius stripe scans. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | [[image:vtube-laser_1_65_radiusstripescansscansrate.jpg|300px]] | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] Other Changes=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | * A bug was found and removed from the MOVE command.<br><br> | ||
+ | * The System Options menu allows you to browse directly into support folders from inside VTube-LASER.<br><br> | ||
+ | * VTube-LASER now uses the "All Users" or "ProgramData" folders to store configuration data for all users of the FARO computer. This solves problems for companies that require that each user login to Windows with their own permissions setup.<br><br> | ||
+ | * The Winton Machinery bender protocol was enhanced so that it automatically loads a template if no data is present in memory when an operator is ready to send data to the bender.<br><br> | ||
+ | |||
</td> | </td> | ||
<td width=300> | <td width=300> |
Latest revision as of 17:24, 19 May 2011
Revision 1.65Back to VTube-LASER |
NEW: Radius Correction for Push-Bending
The radius correction menu allows VTube-LASER to correct push-bends on Unison Limited benders. |
NEW: Bender Setup Changes
The Bender Setup window has a new easier-to-view color scheme.
The bend setup grid has a new column for inverting rotations that are sent out to the bender. This allows for sending the rotation the opposite direction - then remembering the inversion for next time the project is run. |
ENHANCED: New Torus-fit Engine for Radius Stripe Scanning
The new radius stripe scanning method is more accurate as of this version of VTube due to a new torus-fit engine included in VTube.
|
NEW: Bender Data + Corrections Data Chart in Reports
A new bender chart was added to the report template to include the bender data + corrections chart |
ENHANCED: Report Preview Menu
The Report Preview menu now allows you to change the printer and the paper orientation before printing. |
ENHANCED: Measure Setup - Laser Probe Grid
The Laser probe grid now has a separate checkbox for automatically enabling either laser or tactile measuring for radius stripe scans. |
ENHANCED: Measure Setup - Scan Rate Grid
The Scan Rate grid now has a separate controls for radius stripe scans. |
Other Changes
|
Issues with this version fixed in newer versions
|
Other Pages
- Back to VTube-LASER
VTube-LASER Training Video - How to perform effective end scans. |