Difference between revisions of "VTube-LASER v1.68"

From ATTWiki
Jump to: navigation, search
(25px NEW: Added Tab Menus in the MASTER XYZ Menu)
(25px Other Changes)
 
(10 intermediate revisions by one user not shown)
Line 16: Line 16:
  
 
===[[image:Check.jpg|25px]] NEW: Excel Report Builder===
 
===[[image:Check.jpg|25px]] NEW: Excel Report Builder===
 +
[[image:vtube-laser_report_excel_button.jpg|300px]]
  
[[image:vtube-laser_excel.jpg|500px]]
 
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
Line 29: Line 29:
 
</tr>  
 
</tr>  
 
</table>
 
</table>
 +
[[image:vtube-laser_excel.jpg|500px]]
  
 
===[[image:Check.jpg|25px]] REVISED: Overbend Calculator===
 
===[[image:Check.jpg|25px]] REVISED: Overbend Calculator===
Line 36: Line 37:
 
<td width=300>
 
<td width=300>
 
The Overbend Calculator was redesigned and improved.
 
The Overbend Calculator was redesigned and improved.
<br><br>
 
When Cut Plane is active a Cut Plane icon displays at the bottom of the Navigation pane.  (See the orange arrow above.)
 
<br><br>
 
 
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
Line 69: Line 66:
 
</tr>  
 
</tr>  
 
</table>
 
</table>
[[image:vtube-laser_master_xyz_tabmenus.jpg|300px]]
+
[[image:vtube-laser_master_xyz_tabmenus_setpoints.jpg|300px]]<br>
 +
[[image:vtube-laser_master_xyz_tabmenus.jpg|300px]]<br>
 +
[[image:vtube-laser_master_xyz_tabmenus_splitbend.jpg|300px]]<br>
 
<br><br>
 
<br><br>
  
===[[image:Check.jpg|25px]] NEW - Reset Coordinate Datum for MASTER or MEASURED to Zero===
 
[[image:vtube-laser_beforeafterzerodatum.jpg|500px]]
 
<table cellpadding=10>
 
  
<tr valign=top>
 
<td width=300>
 
* This feature allows you to reset the datum of the first row of coordinates to zero.
 
</td>
 
<td width=300>[[image:vtube-laser_resetcoorddatumtozero.jpg|300px]]
 
</td>
 
</tr>
 
  
</table>
 
  
===[[image:Check.jpg|25px]] NEW - Add After Row in MASTER XYZ===
 
<table cellpadding=10>
 
 
<tr valign=top>
 
<td width=300>
 
* Now add rows after the current row in Master XYZ data.  This allows users to add a row after the last row of XYZ coordinates.
 
</td>
 
<td width=300>
 
[[image:vtube-laser_addafterthisrow.jpg|300px]]
 
</td>
 
</tr>
 
 
</table>
 
  
 
===[[image:Check.jpg|25px]] Other Changes===
 
===[[image:Check.jpg|25px]] Other Changes===
Line 105: Line 80:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* The Save Project Before Continuing window now has a third button added that allows you to Cancel the operation that would lose the current project changes.  This allows operations like project file load or program close to be stopped.
+
* The radius values now correctly copy back to XYZ radius values when performing a reverse calc.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-laser_saveproject_beforecontinue.jpg|300px]]
 
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 114: Line 88:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* The Data Handling menu has been updated to include the Split Bend feature.
+
* It is now possible to edit the blue-column bend ANGLE and ANGLE ADJUSMENT data in the Bender Setup menu.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-laser_datahandlingpane_1_67.jpg|300px]]
 
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 123: Line 96:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* The MASTER XYZ grid popup menu now includes the '''Add after this XYZ Row''' feature to allow operators to add XYZ rows after the last row.
+
* A new LRA Master to Measured report is added.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-laser_AddAfterThisXYZRow_1_67.jpg|300px]]
 
 
</td>
 
</td>
 
</tr>
 
</tr>
 
  
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* Cross-check lengths now show negative when the cross-check is short.
+
* Rotation corrections are always shift to the shortest side of the clock.  For example +359 degree is reset to -1.0.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-laser_CrosscheckNegative_1_67.jpg|300px]]
 
 
</td>
 
</td>
 
</tr>
 
</tr>
 
  
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
* Reverse calculation now retains the MASTER part orientation if possible.  This allows you to change the LRA data, press Calculate XYZ, and retain the original orientation of the master part. (Note: v1.67b)<br><br>
+
* Now the tangent point/midpoint inspection grid is automatically set with the default tolerance when the grid grows.
* The example on the right shows an increased third straight length from 2 to 4 inches with the part retaining the original orientation.
+
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-laser_ReverseCalc_OriginalOrientation.jpg|300px]]
 
 
</td>
 
</td>
 
</tr>
 
</tr>

Latest revision as of 23:38, 9 August 2011

Vtube-laser logo.jpg

Revision 1.68

Back to VTube-LASER
Back to VTube-STEP

Vtube-laser screen 1 68.jpg

Contents


Check.jpg NEW: Excel Report Builder

Vtube-laser report excel button.jpg

VTube-LASER can now build a Excel report quickly. This is useful for taking your reports even further for Gage R&R an custom reports.

Vtube-laser excel.jpg

Check.jpg REVISED: Overbend Calculator

Vtube-laser overbend.jpg

The Overbend Calculator was redesigned and improved.

Check.jpg NEW: More Option in the Bender Setup

Vtube-laser bendersetup saveSV.jpg

Bender Setup can now save Supravision files from the bender setup data to the network. The menu can send either bender data with corrections or bender data without corrections. For uni-directional benders, you can merge Adjustments back into the bender data after sending data to the bender.

Check.jpg NEW: Added Tab Menus in the MASTER XYZ Menu

New tab menus with new options are now placed in separate tab menus in the Master XYZ menu.

Vtube-laser master xyz tabmenus setpoints.jpg
Vtube-laser master xyz tabmenus.jpg
Vtube-laser master xyz tabmenus splitbend.jpg




Check.jpg Other Changes

  • The radius values now correctly copy back to XYZ radius values when performing a reverse calc.
  • It is now possible to edit the blue-column bend ANGLE and ANGLE ADJUSMENT data in the Bender Setup menu.
  • A new LRA Master to Measured report is added.
  • Rotation corrections are always shift to the shortest side of the clock. For example +359 degree is reset to -1.0.
  • Now the tangent point/midpoint inspection grid is automatically set with the default tolerance when the grid grows.



Check.jpg Issues with this version fixed in newer versions

  • No known issues



Other Pages

VTube-LASER Training Video - How to perform effective end scans.

Vtube-laser effective end scan video b.jpg