Difference between revisions of "VTube-LASER v1.75.3"

From ATTWiki
Jump to: navigation, search
(25px NEW: Added Automatic Closeup of Last Measure Feature)
(25px NEW: Added To View Control Pane - Only Recently Measured)
 
(7 intermediate revisions by one user not shown)
Line 15: Line 15:
 
__NOTOC__
 
__NOTOC__
  
===[[image:Check.jpg|25px]] NEW: Added Automatic Closeup of Last Measure Feature===
+
===[[image:Check.jpg|25px]] NEW: Added To View Control Pane - Only Recently Measured===
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
VTube can now zoom in on only a recently measured part of the tube shape automatically during measurement.  This speeds up the redraw, and allows the operator to confirm that the last measure was good.
+
The ''Only Recently Measured'' check box is added to allow only the last few measured items to display on the screen.  This allows VTube to zoom in on the most recently measured part of the tube when refreshing the graphics window.</td>
</td>
+
 
<td width=300>
 
<td width=300>
[[image:VTube-LASER_Automatic_Closeup.jpg|300px]]
+
[[image:vtube-laser_OnlyRecentlyMeasured.jpg|192px]]
 
</td>
 
</td>
 
</tr>  
 
</tr>  
 
</table>
 
</table>
  
===[[image:Check.jpg|25px]] FIX: Report Window===
+
===[[image:Check.jpg|25px]] NEW: In Measure Setup - "Automatic Closeup of Last Measure"===
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
VTube now remembers the last ''Automatic Image Update'' state in the Report window.
+
This allows VTube to handle the Only Recently Measured feature automatically during measurement.<br><br>
 +
This speeds up the redraw, and allows the operator to confirm that the last measure was good by magnifying that last object measured.
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:VTube-LASER_ReportWindow.jpg|300px]]
+
[[image:VTube-LASER_Automatic_Closeup.jpg|300px]]
 
</td>
 
</td>
 
</tr>  
 
</tr>  
 
</table>
 
</table>
  
===[[image:Check.jpg|25px]] NEWAdded To View Control Pane===
+
===[[image:Check.jpg|25px]] FIXReport Window===
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
The ''Only Recently Measured'' check box is added to allow only the last few measured items to display on the screen.</td>
+
VTube now remembers the last ''Automatic Image Update'' state in the Report window.
 +
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-laser_OnlyRecentlyMeasured.jpg|192px]]
+
[[image:VTube-LASER_ReportWindow.jpg|300px]]
 
</td>
 
</td>
 
</tr>  
 
</tr>  
 
</table>
 
</table>
 +
 +
  
 
=Other Pages=
 
=Other Pages=
 
*Back to [[VTube-LASER]]
 
*Back to [[VTube-LASER]]

Latest revision as of 17:46, 7 February 2012

Vtube-laser logo.jpg

Revision 1.75.3

Back to VTube-LASER
Back to VTube-STEP

Vtube-laser 1 73.jpg


Check.jpg NEW: Added To View Control Pane - Only Recently Measured

The Only Recently Measured check box is added to allow only the last few measured items to display on the screen. This allows VTube to zoom in on the most recently measured part of the tube when refreshing the graphics window.

Vtube-laser OnlyRecentlyMeasured.jpg

Check.jpg NEW: In Measure Setup - "Automatic Closeup of Last Measure"

This allows VTube to handle the Only Recently Measured feature automatically during measurement.

This speeds up the redraw, and allows the operator to confirm that the last measure was good by magnifying that last object measured.

VTube-LASER Automatic Closeup.jpg

Check.jpg FIX: Report Window

VTube now remembers the last Automatic Image Update state in the Report window.

VTube-LASER ReportWindow.jpg


Other Pages