Difference between revisions of "CNC Bender v12-20120629"

From ATTWiki
Jump to: navigation, search
(25px Repair - Default Option Values in the Toolbox Now Switched Off)
(25px Repair - Fourth Radius Level Loading)
 
(12 intermediate revisions by one user not shown)
Line 13: Line 13:
 
</table>
 
</table>
 
__NOTOC__
 
__NOTOC__
===[[image:Check.jpg|25px]] Repair - Default Option Values in the Toolbox Now Switched Off===
+
===[[image:Check.jpg|25px]] Repair Processlist Builder Proper Tracking of Option In or Out of Toolbox===
  
 +
[[image:cncbender_toolbox_window.jpg|500px]]
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
Line 20: Line 21:
 
By default, dynamic options should be OFF or in their DEFAULT state when in a Toolbox.
 
By default, dynamic options should be OFF or in their DEFAULT state when in a Toolbox.
 
<br><br>
 
<br><br>
However, the CNC Processlist Builder had difficulty determining if an option was inside the toolbox - even if it was inside the toolbox in CNC Bender.  This sometimes caused hard-to-trace side-effects where an option seemed to be active - and causing unintended effects like skipping bends, or calling out to features that were placed in the toolbox.
+
However, the CNC Processlist Builder improperly tracked if an option was inside the toolbox.  This sometimes caused hard-to-trace side-effects where an option seemed to be OUT of the Toolbox to Processlist Builder, but was inside the Toolbox in CNC Bender.  Unintended effects could be as serious as skipping bends for example.
 
<br><br>
 
<br><br>
 
This version fixes this issue by allowing both CNC Bender, CNC Processlist Builder and CNC Processor to track if the operator has placed the option in the Toolbox based on which operator station the part is running in.   
 
This version fixes this issue by allowing both CNC Bender, CNC Processlist Builder and CNC Processor to track if the operator has placed the option in the Toolbox based on which operator station the part is running in.   
Line 32: Line 33:
 
</table>
 
</table>
  
===[[image:Check.jpg|25px]] Repair - Robot Clear Bit Can Be High or Low===
+
===[[image:Check.jpg|25px]] Repair Mixed up or Garbled SVNET Data from Poor Network Connection===
 +
[[image:cncbender_benderlink_screen.jpg|500px]]
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=400>
 +
The Supravision data incoming to CNC Bender Benderlink could be garbled if Benderlink tried to open and access the data to early - while the file is still growing.  Benderlink is now enhanced to watch for the file growth size to stop before opening and taking ownership of the incoming Supravision data.
 +
<br>
 +
</td>
 +
 
 +
<td width=300>
 +
 
 +
</td>
 +
 
 +
</tr>
 +
</table>
 +
 
 +
===[[image:Check.jpg|25px]] Enhance Fourth Radius Level Loading===
  
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
The Robot Clear bit always assumed that the TRUE signal was bit high.  But some machines assume the opposite.  This has been fixed.
+
The new Fourth radius level loading feature (added in the previous version) is enhanced and repaired.
 
<br>
 
<br>
 
</td>
 
</td>

Latest revision as of 02:13, 30 June 2012

v12-20120629

Cncv12procontrol withteachmode.jpg

Check.jpg Repair Processlist Builder Proper Tracking of Option In or Out of Toolbox

Cncbender toolbox window.jpg

By default, dynamic options should be OFF or in their DEFAULT state when in a Toolbox.

However, the CNC Processlist Builder improperly tracked if an option was inside the toolbox. This sometimes caused hard-to-trace side-effects where an option seemed to be OUT of the Toolbox to Processlist Builder, but was inside the Toolbox in CNC Bender. Unintended effects could be as serious as skipping bends for example.

This version fixes this issue by allowing both CNC Bender, CNC Processlist Builder and CNC Processor to track if the operator has placed the option in the Toolbox based on which operator station the part is running in.

Check.jpg Repair Mixed up or Garbled SVNET Data from Poor Network Connection

Cncbender benderlink screen.jpg

The Supravision data incoming to CNC Bender Benderlink could be garbled if Benderlink tried to open and access the data to early - while the file is still growing. Benderlink is now enhanced to watch for the file growth size to stop before opening and taking ownership of the incoming Supravision data.

Check.jpg Enhance Fourth Radius Level Loading

The new Fourth radius level loading feature (added in the previous version) is enhanced and repaired.

Other Pages