Difference between revisions of "VTube-LASER v1.80.1"

From ATTWiki
Jump to: navigation, search
 
(New Enhanced Supravision Output for Correction)
 
(5 intermediate revisions by one user not shown)
Line 20: Line 20:
 
<br><br>
 
<br><br>
  
===New Transform MASTER Centerline Data so Any Bend is True in the XY Plane===
+
===New Enhanced Supravision Output for Correction===
*Transform the centerline orientation so that any bend is true.
+
Two new sections are added to the Supravision correction file output by VTube-LASER.
*The 0,0,0 datum is always placed at the center of the true bend radius.
+
*This feature can be combined with the Excel output in order to automate the building of compound tools in solid model programs.
+
<br>
+
[[image:vtube_transform_truebend_one.jpg|400px]]
+
<br><br>
+
Before transformation:<br>
+
[[image:vtube_hvac_transform_none.jpg|300px]]<br>
+
  
After transformation with bend 1 true to the XY plane:<br>
+
* The $mlra section contains master LRA data.
[[image:vtube_hvac_transform_one.jpg|300px]]<br>
+
* The $alra section contains LRA adjustments.
<br><br>
+
  
===End Trim Length Fix===
+
These two sections are not included in the standard Supravision file format.  However, we added them to give more information to the operator stations that are connected to VTube-LASER.
*For single bends in the inspection grid, the end trim lengths were 1/2 the correct value.  VTube-LASER was incorrectly considering single bends as single straight parts.  This is corrected.<br>
+
[[image:vtube-laser_singlebend_inspectionscreen.jpg|400px]]
+
<br><br>
+
  
===Updated Hardware Key Driver===
+
See the two new sections in this Supravision data:
*The latest version of the SafeNet hardware key driver is included in this installation.<br>
+
[[image:safenet_hardwarekey_installation.jpg|400px]]
+
<br><br>
+
  
===Other Changes===
+
<pre>
*Removed the dashes from radius zeros in XYZ charts.
+
$pnum VTube-LASER Demo 2
*Added new "XYZ" report that includes only the XYZ data for use in importing XYZ data to solid model programs like Autodesk Inventor through Excel.
+
*Removed Cut Plane request after connect to the arm.  Users know to do this if necessary - so there is no need to put the question on the screen.
+
*This new installation does not interfere with current report templates.  It will automatically add new reports only if they are not already in the report template list.
+
  
<br><br>
+
$unit E
 +
 
 +
$mxyz 8
 +
-0.24141603 1.61318569 25.82424816 0.00000000
 +
3.35605374 1.59472711 25.90821393 2.00000000
 +
5.95105823 -1.13098972 25.95396895 2.00000000
 +
10.80490221 -1.11747307 25.99466236 2.00000000
 +
10.57175944 -1.09267882 33.66648703 2.00000000
 +
14.62776439 -1.11607745 33.77900497 2.00000000
 +
14.80928906 -1.05569072 26.24506866 2.00000000
 +
18.75184347 1.28005457 26.30192065 0.00000000
 +
 
 +
$mlra 6
 +
0.74728411 0.00000000 46.10982661 2.00000000
 +
2.05191265 178.81677502 46.56470905 2.00000000
 +
1.94896199 90.31447026 91.25978409 2.00000000
 +
3.62560446 179.50643129 90.15267826 2.00000000
 +
0.04490178 0.64210001 90.21144350 2.00000000
 +
3.55362571
 +
2.60752275
 +
 
 +
$alra 6
 +
-0.00470749 0.00000000 -0.17966270 0.00000000
 +
0.01539355 -0.04397661 -0.06495980 0.00000000
 +
-0.00338193 -0.06779135 -0.06974093 0.00000000
 +
-0.01247455 -0.02509116 -0.05718667 0.00000000
 +
-0.01336105 0.05554016 -0.02683098 0.00000000
 +
-0.00160111
 +
 
 +
$clra 5
 +
2.99529251 0 0 0 0.00000000 0 0 0 44.82033730 0 0 0 1.50000000
 +
2.51539355 0 0 0 179.95602339 0 0 0 44.93504020 0 0 0 1.50000000
 +
2.62161807 0 0 0 89.93220865 0 0 0 89.93025907 0 0 0 1.50000000
 +
2.61252545 0 0 0 -180.02509116 0 0 0 89.94281333 0 0 0 1.50000000
 +
0.00000000 0 0 0 0.05554016 0 0 0 89.97316902 0 0 0 1.50000000
 +
2.62339889 0 0 0
 +
 
 +
$pvar 2
 +
TBDI 0.31496063
 +
PRBR 0.70866142
 +
 
 +
 
 +
</pre>
 +
 
 +
===New Grid Header Text Redraw===
 +
*Solved redraw issue for grid header text on slower computers.
 +
<br>
 +
 
 +
===Silenced Error Message for No Sound Driver===
 +
*The error message for no sound driver is silenced in STEP mode.<br>
 +
<br>
  
 
===Other Pages===
 
===Other Pages===

Latest revision as of 04:08, 3 December 2012

Vtube-laser logo.jpg

Revision 1.80.1

Vtube-laser 1.78.jpg




New Enhanced Supravision Output for Correction

Two new sections are added to the Supravision correction file output by VTube-LASER.

  • The $mlra section contains master LRA data.
  • The $alra section contains LRA adjustments.

These two sections are not included in the standard Supravision file format. However, we added them to give more information to the operator stations that are connected to VTube-LASER.

See the two new sections in this Supravision data:

$pnum VTube-LASER Demo 2

$unit E

$mxyz 8
-0.24141603 1.61318569 25.82424816 0.00000000
3.35605374 1.59472711 25.90821393 2.00000000
5.95105823 -1.13098972 25.95396895 2.00000000
10.80490221 -1.11747307 25.99466236 2.00000000
10.57175944 -1.09267882 33.66648703 2.00000000
14.62776439 -1.11607745 33.77900497 2.00000000
14.80928906 -1.05569072 26.24506866 2.00000000
18.75184347 1.28005457 26.30192065 0.00000000

$mlra 6
0.74728411 0.00000000 46.10982661 2.00000000
2.05191265 178.81677502 46.56470905 2.00000000
1.94896199 90.31447026 91.25978409 2.00000000
3.62560446 179.50643129 90.15267826 2.00000000
0.04490178 0.64210001 90.21144350 2.00000000
3.55362571
2.60752275

$alra 6
-0.00470749 0.00000000 -0.17966270 0.00000000
0.01539355 -0.04397661 -0.06495980 0.00000000
-0.00338193 -0.06779135 -0.06974093 0.00000000
-0.01247455 -0.02509116 -0.05718667 0.00000000
-0.01336105 0.05554016 -0.02683098 0.00000000
-0.00160111

$clra 5
2.99529251 0 0 0 0.00000000 0 0 0 44.82033730 0 0 0 1.50000000
2.51539355 0 0 0 179.95602339 0 0 0 44.93504020 0 0 0 1.50000000
2.62161807 0 0 0 89.93220865 0 0 0 89.93025907 0 0 0 1.50000000
2.61252545 0 0 0 -180.02509116 0 0 0 89.94281333 0 0 0 1.50000000
0.00000000 0 0 0 0.05554016 0 0 0 89.97316902 0 0 0 1.50000000
2.62339889 0 0 0

$pvar 2
TBDI 0.31496063
PRBR 0.70866142


New Grid Header Text Redraw

  • Solved redraw issue for grid header text on slower computers.


Silenced Error Message for No Sound Driver

  • The error message for no sound driver is silenced in STEP mode.


Other Pages