− | + | Master power pops off/on from time to time. | |
</td> | </td> | ||
<td bgcolor="#e3e4f5"> | <td bgcolor="#e3e4f5"> | ||
<ol> | <ol> | ||
− | + | The output module sustain time is either too low, or some other process in the operator station is taking too much of the CPU time. It is possible that the name of the output module in this menu is incorrect. If this is the case then the default sustain time of 1 second is used. (One second is too low for most bender systems.) | |
− | + | ||
</ol> | </ol> | ||
</td> | </td> | ||
Line 41: | Line 40: | ||
− | + | ===Changing the Value=== | |
− | --[[User:Mcone|Mcone]] | + | Change the value by touching the field in the Special Communications Parameters section. Set the value in whole seconds. |
+ | |||
+ | [[Image:cnclite_lowlevel_processor_output10seconds.jpg|CNC Bender Lite - PROCESSOR Tab, Special Communications section of Low Level Menu]] | ||
+ | |||
+ | |||
+ | In this example, the value has been changed to 30 seconds. | ||
+ | |||
+ | [[Image:cnclite_lowlevel_processor_output30seconds_circled.jpg|CNC Bender Lite - PROCESSOR Tab, Special Communications section of Low Level Menu]] | ||
+ | |||
+ | |||
+ | |||
+ | See also [[Master Power On]]<br> | ||
+ | |||
+ | --[[User:Mcone|Mcone]] 15:03, 11 January 2007 (EST) |
Latest revision as of 20:19, 11 January 2007
Why Change This Value?
Master power shuts off during Process List build. |
|
Master power pops off/on from time to time. |
|
Changing the Value
Change the value by touching the field in the Special Communications Parameters section. Set the value in whole seconds.
In this example, the value has been changed to 30 seconds.
See also Master Power On