==[[image:Check.jpg|25px]] ENHANCED - New Serial Port COM Engine Available == | ==[[image:Check.jpg|25px]] ENHANCED - New Serial Port COM Engine Available == | ||
+ | |||
+ | <table> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
This Benderlink can use either the new WinSoft COM engine for faster communications, or the older MarshallSoft COM engine for cases where the older engine works better.<br><br> | This Benderlink can use either the new WinSoft COM engine for faster communications, or the older MarshallSoft COM engine for cases where the older engine works better.<br><br> | ||
− | The Benderlink.ini file is found in the c:\Users\[username]\AppData\Roaming\BenderlinkChiyodaKeins folder.<br><br>Edit the Benderlink.ini in a notepad editor. The section to change is Communications Setup "COM Engine". These are the two available setups:<br><br> | + | The Benderlink.ini file is found in the <b>c:\Users\[username]\AppData\Roaming\BenderlinkChiyodaKeins</b> folder.<br><br>Edit the Benderlink.ini in a notepad editor. The section to change is Communications Setup "COM Engine". These are the two available setups:<br><br> |
<pre> | <pre> | ||
[Communications Setup] | [Communications Setup] | ||
Line 30: | Line 34: | ||
COM Engine=Marshallsoft | COM Engine=Marshallsoft | ||
</pre> | </pre> | ||
− | |||
− | |||
<br><br> | <br><br> | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:benderlink_chiyodakeins_comengine_indicator.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
==[[image:Check.jpg|25px]] ENHANCED - New CONVERSION Menu Option: Stop for Zero Diameter == | ==[[image:Check.jpg|25px]] ENHANCED - New CONVERSION Menu Option: Stop for Zero Diameter == | ||
<table> | <table> | ||
− | <tr> | + | <tr valign=top> |
<td width=400> | <td width=400> | ||
Line 44: | Line 52: | ||
If this feature is deactivated, then Benderlink will ignore zero value radii values. In this case, Benderlink will automatically change a zero value diameter to non-zero using this formula: | If this feature is deactivated, then Benderlink will ignore zero value radii values. In this case, Benderlink will automatically change a zero value diameter to non-zero using this formula: | ||
<br><br> | <br><br> | ||
− | (Rad Level 1) / 1.5<br><br> | + | <b>(Rad Level 1) / 1.5</b><br><br> |
If the Rad Level 1 value is zero, then Benderlink will use this formula:<br><br> | If the Rad Level 1 value is zero, then Benderlink will use this formula:<br><br> | ||
− | (Rad Level 2) / 1.5<br><br> | + | <b>(Rad Level 2) / 1.5</b><br><br> |
− | If both radius level values are zero, then Benderlink will set the diameter to 1 unit.<br><br>A non-zero diameter is important for communicating with ROMER DOCS software because DOCS will report a corrupted file if it senses a zero | + | |
+ | * If both radius level values are zero, then Benderlink will set the diameter to 1 unit.<br><br>A non-zero diameter is important for communicating with ROMER [[DOCS]] software because DOCS will report a corrupted file if it senses a zero diameter. (Some measuring center software packages, like [[VTube-LASER]] will continue with a zero diameter.)<br><br> | ||
+ | * If the radius stop is enabled, and Benderlink stops for input while the measuring center is performing a recall, then the recall process will time out if the new diameter is not entered within the time out period. | ||
</td> | </td> | ||
Line 56: | Line 66: | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | <br><br> | ||
==OTHER PAGES== | ==OTHER PAGES== |
Latest revision as of 13:21, 15 November 2013
Revision 6.7Back to Benderlink for Chiyoda |
ENHANCED - New Serial Port COM Engine Available
This Benderlink can use either the new WinSoft COM engine for faster communications, or the older MarshallSoft COM engine for cases where the older engine works better. [Communications Setup] COM Engine=WinSoft or [Communications Setup] COM Engine=Marshallsoft
|
ENHANCED - New CONVERSION Menu Option: Stop for Zero Diameter
Benderlink can now stop the process and ask for input if a zero diameter is encountered. If this feature is deactivated, then Benderlink will ignore zero value radii values. In this case, Benderlink will automatically change a zero value diameter to non-zero using this formula:
|
OTHER PAGES
- Back to Benderlink for KEINS
- Back to Benderlink for Chiyoda
- Benderlink for Chiyoda FAQ
- About Chiyoda - See this page for control version information.