Difference between revisions of "VTube-STEP v1.91"
From ATTWiki
(→25px ENHANCED: QuickLoad Improved With New Default Folder Button) |
(→25px NEW: Automatic Calculation of Cut Length) |
||
(9 intermediate revisions by one user not shown) | |||
Line 11: | Line 11: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | [[image:vtube-step-1. | + | [[image:vtube-step-1.91_screenshot.png|300px]] |
</td> | </td> | ||
</tr> | </tr> | ||
Line 22: | Line 22: | ||
− | ===[[image:Check.jpg|25px]] NEW: | + | ===[[image:Check.jpg|25px]] NEW: AUTOMATIC Calculation of Cut Length === |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
Line 39: | Line 39: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400> | <td width=400> | ||
− | If the wall thickness is zero after a centerline calculation from solid model, then VTube now automatically | + | If the wall thickness is zero after a centerline calculation from solid model, then VTube will now automatically insert a value of 0.001" (or 0.0254mm) into the part setup. This cleans up the image by removing solid ends in the display.<br><br> |
<br><br> | <br><br> | ||
</td> | </td> | ||
Line 60: | Line 60: | ||
</table> | </table> | ||
− | + | ==[[image:Check.jpg|25px]] Enhanced: Project Batch Report Output == | |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400> | <td width=400> | ||
− | + | * We added a second type of report per a customer spec. | |
− | + | * The reports are now built to both comma delimted and tab delimited files. | |
− | + | * The reports can be sent directly to Excel.<br><br> | |
− | + | Load the batch reporter in the Report menu of either STEP mode of LASER mode:<br><br> | |
− | + | [[image:vtube-1.90-project_batch_report_button.png|300px]]<br><br> | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | [[image:vtube-1.90- | + | |
</td> | </td> | ||
− | <td width= | + | <td width=300> |
− | + | [[image:vtube-1.90-project_batch_report_output.png|300px]]<br><br> | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | [[image:vtube-1.90- | + | |
− | + | ||
− | + | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 106: | Line 82: | ||
This is a sample report file:<br><br> | This is a sample report file:<br><br> | ||
− | [[image:vtube-1.90-project_batch_report_file1.png| | + | [[image:vtube-1.90-project_batch_report_file1.png|300px]]<br><br> |
</td> | </td> | ||
− | <td width= | + | <td width=300> |
If the batch reporter finds files with 0 or negative length straights, then it will issue a WARNING at the end of the report log and create a second report file containing a list of all the project files with these lengths:<br><br> | If the batch reporter finds files with 0 or negative length straights, then it will issue a WARNING at the end of the report log and create a second report file containing a list of all the project files with these lengths:<br><br> | ||
− | [[image:vtube-1.90-project_batch_report_file2.png| | + | [[image:vtube-1.90-project_batch_report_file2.png|300px]]<br><br> |
</td> | </td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | + | ==[[image:Check.jpg|25px]] Other Changes== | |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400> | <td width=400> | ||
− | + | * Now you can press the Enter key to close the information dialog.<br><br> | |
− | + | * Comments display in a dialog during project load<br><br> | |
− | + | * The "Clear text" button in the editor box works again.<br><br> | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | * | + | |
− | + | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
Line 141: | Line 104: | ||
</tr> | </tr> | ||
</table> | </table> | ||
− | |||
==Other== | ==Other== |
Latest revision as of 14:13, 30 June 2014
Revision 1.91
|
- See VTube-STEP Customer Support Page to download the latest version.
NEW: AUTOMATIC Calculation of Cut Length
VTube-STEP now automatically calculates the cut length during calculation of the centerline from solid model. |
NEW: AUTOMATIC Thin Wall
If the wall thickness is zero after a centerline calculation from solid model, then VTube will now automatically insert a value of 0.001" (or 0.0254mm) into the part setup. This cleans up the image by removing solid ends in the display. |
ENHANCED: QuickLoad Improved With New Default Folder Button
The Quickload window has a new button that allows you to find the default VTube folder in public documents quickly. |
Enhanced: Project Batch Report Output
Other Changes
|
Other
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER