Difference between revisions of "VTube-STEP v1.93"
From ATTWiki
(→25px NEW: Added the End A / End B Diameter Values in STEP Mode Part Setup) |
(→25px NEW: Added the End A and End B Diameter Values in STEP Mode Part Setup) |
||
(16 intermediate revisions by one user not shown) | |||
Line 10: | Line 10: | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | [[image:vtube-step-1. | + | [[image:vtube-step-1.93_screenshot.png|300px]] |
</td> | </td> | ||
</tr> | </tr> | ||
Line 19: | Line 19: | ||
<br> | <br> | ||
− | ===[[image:Check.jpg|25px]] NEW: Added the End A | + | ===[[image:Check.jpg|25px]] NEW: Import CSM M3 Bender Files=== |
+ | [[image:vtube-step-1.93_csm_m3_import_button.png]] | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | VTube-STEP can now import CSM M3 bender files.<br><br> | ||
+ | * Import the centerline XYZ data. | ||
+ | * Or import the YBC data.<br><br> | ||
+ | [[image:vtube-step-1.93_csm_m3_import_radiobuttons.png]]<br><br> | ||
+ | * Other values imported are: | ||
+ | ** Diameter | ||
+ | ** Wall Thickness | ||
+ | ** Pre Length (Start Length) | ||
+ | ** End Length | ||
+ | ** Cut Length | ||
+ | ** Pipe Material Note | ||
+ | </td> | ||
+ | <td width=500> | ||
+ | [[image:vtube-step-1.93_csm_m3_importfeature.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Added the End A and End B Diameter Values in STEP Mode Part Setup === | ||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
Line 28: | Line 51: | ||
<td width=500> | <td width=500> | ||
[[image:vtube-1.93_EndDiameters.png|400px]] | [[image:vtube-1.93_EndDiameters.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Added the Default Tolerance Value in Part Setup === | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | Some output formats prefer to have a default tolerance built into the export, so now the Default Tolerance value is included in the VTube-STEP Part Setup menu.<br><br> | ||
+ | </td> | ||
+ | <td width=500> | ||
+ | [[image:vtube-1.93_DefaultTolerance_PartSetup.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Automatic Set of End Diameters When Calculating Centerlines === | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | The end diameters are now set to equal the main diameter during centerline calculation from models. | ||
+ | </td> | ||
+ | <td width=500> | ||
+ | [[image:vtube-1.93_EndDiameters_Model.png|400px]] | ||
</td> | </td> | ||
</tr> | </tr> | ||
Line 37: | Line 85: | ||
<td width=300> | <td width=300> | ||
The pop up menus for the Part Setup menu (STEP and LASER modes) now allow for the end diameters to be synchronized with the main diameter.<br><br> | The pop up menus for the Part Setup menu (STEP and LASER modes) now allow for the end diameters to be synchronized with the main diameter.<br><br> | ||
+ | </td> | ||
+ | <td width=400> | ||
+ | [[image:vtube-1.93_SyncEndDiametersPopup.png|400px]]<br><br> | ||
+ | [[image:vtube-1.93_EndDiametersAfter.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCED: Fine-Tune Export to Laservision Spreadsheet Format Files === | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | The Eaton Leonard Laservision measuring center can import CSV (Comma Separated Value) files built in an Excel spreadsheet. This version of VTube can now export to this format. This version fine-tunes the new feature to make the output conform to customer specifications for the project.<br><br> | ||
</td> | </td> | ||
<td width=500> | <td width=500> | ||
− | [[image:vtube-1. | + | [[image:vtube-step-1.93_export_laservision.png|400px]]<br><br></td> |
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Previous Paths List in Quick Open === | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | The Quick Open dialog now has a pull-down list that shows all the recent previous paths used to load VTube project files or imported solid model files.<br><br> | ||
+ | Click on the previous path to use, and the folder tree on the left will open the new folder. | ||
</td> | </td> | ||
+ | <td width=500> | ||
+ | [[image:vtube-1.93_PreviousPaths.png|400px]]<br><br></td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
Line 48: | Line 121: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400> | <td width=400> | ||
+ | |||
+ | * Updated the Chinese translation. | ||
+ | * Updated the German translation. | ||
Latest revision as of 17:52, 23 July 2014
Revision 1.93
|
- See VTube-STEP Customer Support Page to download the latest version.
NEW: Import CSM M3 Bender Files
VTube-STEP can now import CSM M3 bender files.
|
NEW: Added the End A and End B Diameter Values in STEP Mode Part Setup
The End A and End B diameters were only in VTube-LASER. Now they are in VTube-STEP in order to allow users to control the data when outputting data to a Supravision file in VTube-STEP. |
NEW: Added the Default Tolerance Value in Part Setup
Some output formats prefer to have a default tolerance built into the export, so now the Default Tolerance value is included in the VTube-STEP Part Setup menu. |
NEW: Automatic Set of End Diameters When Calculating Centerlines
The end diameters are now set to equal the main diameter during centerline calculation from models. |
NEW: Added to the Popup Menu to Synchronize End Diameters with Main Diameter
The pop up menus for the Part Setup menu (STEP and LASER modes) now allow for the end diameters to be synchronized with the main diameter. |
ENHANCED: Fine-Tune Export to Laservision Spreadsheet Format Files
NEW: Previous Paths List in Quick Open
Other Changes
|
Other Pages
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER