(Created page with "<table> <tr> <td width=400> ===v12.11 - July 16, 2014=== *Back to CNC Bender Software Updates *See [http://advancedtubular.com/customers/cncbender CNC Bender Customer Serv...")
 
(25px NEW: New PostBend Option - Release Shift Away)
 
(12 intermediate revisions by one user not shown)
Line 16: Line 16:
 
__NOTOC__
 
__NOTOC__
  
==[[image:Check.jpg|25px]] ENHANCED: No Longer Clear Tool with Tube==
+
==[[image:Check.jpg|25px]] NEW: New PostBend Option - Release Shift Away==
  
 
<table>
 
<table>
 
<tr>
 
<tr>
<td width=400>
+
<td width=300>
  
<h4><b>If you have a hand-bender controlled by CNC Bender and you use custom commands for the ROTATE axis, then this upgrade is important to you.</b></h4>
+
A PostBend Release Shift Away option is added that allows the process to shift the tube out of the dies just after the dies open in the RELEASE section of the process.<br><br>
 +
* This option has no effect in any release mode that involves a robot.
 +
* This option has no effect in the Custom Release mode.
 +
* It works in all other modes.
 +
<td>
 +
[[image:cnc_v12.11_postbend_releaseshiftaway.png|500px]]
 +
</td>
 +
</tr>
 +
</table>
  
Custom commands can be entered after every bend in the FRB page.  SMT discovered a that FEED and ROTATE commands would not be completed properly when coming out of a custom move.<br><br>
+
<br><br>
* For example, the ROTATE was programmed at 90 degrees.  The custom move is 89 degrees - so the finish up command should be set to 1 degree to come to the full 90. However, the finish-up command was 90 degrees - which caused the rotate to move to 89 + 90 = 179 degrees.<br><br>
+
 
* This problem occurred on benders where the ROTATE axis is set to a non-standard machine axis 3 because the machine axis number "2" was hard coded into the process list builder.<br><br>
+
==[[image:Check.jpg|25px]] ENHANCED: No Longer Clear Tool Data Page with TubeShape Clear==
* Process list builder now has logic that anticipates that the machine axis number for any motion actuator can change depending on the application.
+
 
 +
<table>
 +
<tr>
 +
<td width=300>
  
 +
Previous versions of CNC Bender would clear the Tool page when the Tube Shape page was cleared.  This creates a problem in workflow, because the tool data is setup before the part is setup.  Clearing the TubeShape page should never clear the tool page.<br><br>
 +
This issue has been resolved in this version.
 
<td>
 
<td>
[[image:smt_handbender.png|400px]]
+
[[image:cnc_v12.11_tubeshape_notclear_toolpage.png|500px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
 
</table>
 
</table>
  
<br><br>
 
 
<br><br>
 
<br><br>
  
==[[image:Check.jpg|25px]] ENHANCED: Load and Start Positions with Bend Arm Motion Option (in Pre Bend)==
+
==[[image:Check.jpg|25px]] FIX: Custom Command Editor==
  
 
<table>
 
<table>
 
<tr>
 
<tr>
 
<td width=300>
 
<td width=300>
The Option List panels now clear if all options are placed in the tool box.<br><br>
+
The Custom Commands menu and Custom Command Editor would sometimes show an error when clearing the menu then re-entering the Editor.<br><br>
 +
This problem has been resolved in this version.
  
 
<td width=300>
 
<td width=300>
[[image:cncbender_OptionPanelCleared.png|600px]]
+
[[image:cnc_v12.11_customcommand_editor.png|500px]]
 +
</td>
 +
<td>
 +
</td>
 +
</tr>
 +
</table><br><br>
 +
 
 +
 
 +
==[[image:Check.jpg|25px]] ENHANCED: CNC Program Loader Allows for Adjustable CNC Executable Location==
 +
 
 +
<table>
 +
<tr>
 +
<td width=300>
 +
The location of the CNC Bender executable files can change depending on the application.  The Program Loader can now run the CNC Bender program from any location - not just the standard "C:\CNC" folder location.
 +
 
 +
<td width=300>
 +
[[image:cnc_v12.11_programloader.png|500px]]
 
</td>
 
</td>
 
<td>
 
<td>
Line 58: Line 87:
 
<tr>
 
<tr>
 
<td width=400>
 
<td width=400>
* New version number set in all executables: 12.8
+
* Removed the second scroll bar on the right side of the File Load menu since it was redundant.
  
 
</td>
 
</td>
Line 67: Line 96:
  
 
<br><br>
 
<br><br>
 
  
 
==Other Pages==
 
==Other Pages==

Latest revision as of 20:37, 16 July 2014

v12.11 - July 16, 2014

Cncv12procontrol withteachmode.jpg


Check.jpg NEW: New PostBend Option - Release Shift Away

A PostBend Release Shift Away option is added that allows the process to shift the tube out of the dies just after the dies open in the RELEASE section of the process.

  • This option has no effect in any release mode that involves a robot.
  • This option has no effect in the Custom Release mode.
  • It works in all other modes.

Cnc v12.11 postbend releaseshiftaway.png



Check.jpg ENHANCED: No Longer Clear Tool Data Page with TubeShape Clear

Previous versions of CNC Bender would clear the Tool page when the Tube Shape page was cleared. This creates a problem in workflow, because the tool data is setup before the part is setup. Clearing the TubeShape page should never clear the tool page.

This issue has been resolved in this version.

Cnc v12.11 tubeshape notclear toolpage.png



Check.jpg FIX: Custom Command Editor

The Custom Commands menu and Custom Command Editor would sometimes show an error when clearing the menu then re-entering the Editor.

This problem has been resolved in this version.

Cnc v12.11 customcommand editor.png




Check.jpg ENHANCED: CNC Program Loader Allows for Adjustable CNC Executable Location

The location of the CNC Bender executable files can change depending on the application. The Program Loader can now run the CNC Bender program from any location - not just the standard "C:\CNC" folder location.

Cnc v12.11 programloader.png



Check.jpg Other Changes

  • Removed the second scroll bar on the right side of the File Load menu since it was redundant.