Difference between revisions of "VTube-STEP v1.93"

From ATTWiki
Jump to: navigation, search
(25px NEW: Added the End A and End B Diameter Values in STEP Mode Part Setup)
(25px NEW: Added the End A and End B Diameter Values in STEP Mode Part Setup)
 
(9 intermediate revisions by one user not shown)
Line 10: Line 10:
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>
[[image:vtube-step-1.92_screenshot.png|300px]]
+
[[image:vtube-step-1.93_screenshot.png|300px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 20: Line 20:
  
 
===[[image:Check.jpg|25px]] NEW: Import CSM M3 Bender Files===
 
===[[image:Check.jpg|25px]] NEW: Import CSM M3 Bender Files===
 +
[[image:vtube-step-1.93_csm_m3_import_button.png]]
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
VTube-STEP can now import CSM M3 controlled bender files.<br><br>
+
VTube-STEP can now import CSM M3 bender files.<br><br>
* The import feature can import the centerline XYZ data.
+
* Import the centerline XYZ data.
* The import feature can import the YBC data and convert to centerline XYZ data.
+
* Or import the YBC data.<br><br>
* The other values imported are:
+
[[image:vtube-step-1.93_csm_m3_import_radiobuttons.png]]<br><br>
 +
* Other values imported are:
 
** Diameter
 
** Diameter
 
** Wall Thickness
 
** Wall Thickness
Line 35: Line 37:
 
</td>
 
</td>
 
<td width=500>
 
<td width=500>
[[image:vtube-1.93_ImportCSMM3.png|400px]]
+
[[image:vtube-step-1.93_csm_m3_importfeature.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
 
</table>
 
</table>
 
 
  
 
===[[image:Check.jpg|25px]] NEW: Added the End A and End B Diameter Values in STEP Mode Part Setup  ===
 
===[[image:Check.jpg|25px]] NEW: Added the End A and End B Diameter Values in STEP Mode Part Setup  ===
Line 51: Line 51:
 
<td width=500>
 
<td width=500>
 
[[image:vtube-1.93_EndDiameters.png|400px]]
 
[[image:vtube-1.93_EndDiameters.png|400px]]
 +
</td>
 +
</tr>
 +
</table>
 +
 +
 +
===[[image:Check.jpg|25px]] NEW: Added the Default Tolerance Value in Part Setup  ===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 +
Some output formats prefer to have a default tolerance built into the export, so now the Default Tolerance value is included in the VTube-STEP Part Setup menu.<br><br>
 +
</td>
 +
<td width=500>
 +
[[image:vtube-1.93_DefaultTolerance_PartSetup.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 88: Line 101:
 
<td width=500>
 
<td width=500>
 
[[image:vtube-step-1.93_export_laservision.png|400px]]<br><br></td>
 
[[image:vtube-step-1.93_export_laservision.png|400px]]<br><br></td>
 +
</tr>
 +
</table>
 +
 +
 +
===[[image:Check.jpg|25px]] NEW: Previous Paths List in Quick Open ===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 +
The Quick Open dialog now has a pull-down list that shows all the recent previous paths used to load VTube project files or imported solid model files.<br><br>
 +
Click on the previous path to use, and the folder tree on the left will open the new folder.
 +
</td>
 +
<td width=500>
 +
[[image:vtube-1.93_PreviousPaths.png|400px]]<br><br></td>
 
</tr>
 
</tr>
 
</table>
 
</table>
Line 95: Line 121:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
 +
 +
* Updated the Chinese translation.
 +
* Updated the German translation.
  
  

Latest revision as of 17:52, 23 July 2014

Vtube-step logo.jpg

Revision 1.93

Vtube-step-1.93 screenshot.png



Check.jpg NEW: Import CSM M3 Bender Files

Vtube-step-1.93 csm m3 import button.png

VTube-STEP can now import CSM M3 bender files.

  • Import the centerline XYZ data.
  • Or import the YBC data.

Vtube-step-1.93 csm m3 import radiobuttons.png

  • Other values imported are:
    • Diameter
    • Wall Thickness
    • Pre Length (Start Length)
    • End Length
    • Cut Length
    • Pipe Material Note

Vtube-step-1.93 csm m3 importfeature.png

Check.jpg NEW: Added the End A and End B Diameter Values in STEP Mode Part Setup

The End A and End B diameters were only in VTube-LASER. Now they are in VTube-STEP in order to allow users to control the data when outputting data to a Supravision file in VTube-STEP.

The two values are placed immediately after the Diameter field.

Vtube-1.93 EndDiameters.png


Check.jpg NEW: Added the Default Tolerance Value in Part Setup

Some output formats prefer to have a default tolerance built into the export, so now the Default Tolerance value is included in the VTube-STEP Part Setup menu.

Vtube-1.93 DefaultTolerance PartSetup.png

Check.jpg NEW: Automatic Set of End Diameters When Calculating Centerlines

The end diameters are now set to equal the main diameter during centerline calculation from models.

Vtube-1.93 EndDiameters Model.png

Check.jpg NEW: Added to the Popup Menu to Synchronize End Diameters with Main Diameter

The pop up menus for the Part Setup menu (STEP and LASER modes) now allow for the end diameters to be synchronized with the main diameter.

Vtube-1.93 SyncEndDiametersPopup.png

Vtube-1.93 EndDiametersAfter.png

Check.jpg ENHANCED: Fine-Tune Export to Laservision Spreadsheet Format Files

The Eaton Leonard Laservision measuring center can import CSV (Comma Separated Value) files built in an Excel spreadsheet. This version of VTube can now export to this format. This version fine-tunes the new feature to make the output conform to customer specifications for the project.

Vtube-step-1.93 export laservision.png


Check.jpg NEW: Previous Paths List in Quick Open

The Quick Open dialog now has a pull-down list that shows all the recent previous paths used to load VTube project files or imported solid model files.

Click on the previous path to use, and the folder tree on the left will open the new folder.

Vtube-1.93 PreviousPaths.png

Check.jpg Other Changes

  • Updated the Chinese translation.
  • Updated the German translation.


Other Pages