Difference between revisions of "VTube-LASER v1.93"
From ATTWiki
(Created page with "<table> <tr cellpadding=10> <td width=225> 300px ==Revision 1.92== * Back to VTube-STEP * Back to VTube-STEP Revisions * Back to VTube...") |
(→25px NEW: Added to the Popup Menu to Synchronize End Diameters with Main Diameter) |
||
(8 intermediate revisions by one user not shown) | |||
Line 3: | Line 3: | ||
<td width=225> | <td width=225> | ||
[[image:vtube-laser_logo.jpg|300px]] | [[image:vtube-laser_logo.jpg|300px]] | ||
− | ==Revision 1. | + | ==Revision 1.93== |
* Back to [[VTube-STEP]] | * Back to [[VTube-STEP]] | ||
* Back to [[VTube-STEP Revisions]] | * Back to [[VTube-STEP Revisions]] | ||
Line 23: | Line 23: | ||
− | ===[[image:Check.jpg|25px]] NEW: | + | ===[[image:Check.jpg|25px]] NEW: Import CSM M3 Bender Files (VTube-STEP Mode)=== |
+ | [[image:vtube-step-1.93_csm_m3_import_button.png]] | ||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
− | <td width= | + | <td width=300> |
− | + | (The VTube-STEP mode is included with VTube-LASER.) VTube-STEP can now import CSM M3 bender files.<br><br> | |
− | + | * Import the centerline XYZ data. | |
− | + | * Or import the YBC data.<br><br> | |
− | * | + | [[image:vtube-step-1.93_csm_m3_import_radiobuttons.png|300px]]<br><br> |
− | * | + | * Other values imported are: |
− | + | ** Diameter | |
− | [[image:vtube-step-1. | + | ** Wall Thickness |
+ | ** Pre Length (Start Length) | ||
+ | ** End Length | ||
+ | ** Cut Length | ||
+ | ** Pipe Material Note | ||
</td> | </td> | ||
<td width=500> | <td width=500> | ||
− | [[image: | + | [[image:vtube-step-1.93_csm_m3_importfeature.png|400px]] |
− | + | ||
</td> | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Added the Default Tolerance Value in Part Setup === | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | Some output formats prefer to have a default tolerance built into the export, so now the Default Tolerance value is included in the VTube-LASER Part Setup menu.<br><br> | ||
+ | </td> | ||
+ | <td width=500> | ||
+ | [[image:vtube-1.93_DefaultTolerance_PartSetup.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Added to the Popup Menu to Synchronize End Diameters with Main Diameter === | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | The pop up menus for the Part Setup menu (STEP and LASER modes) now allow for the end diameters to be synchronized with the main diameter.<br><br> | ||
+ | </td> | ||
+ | <td width=400> | ||
+ | [[image:vtube-1.93_SyncEndDiametersPopup.png|400px]]<br><br> | ||
+ | [[image:vtube-1.93_EndDiametersAfter.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Previous Paths List in Quick Open === | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | The Quick Open dialog now has a pull-down list that shows all the recent previous paths used to load VTube project files or imported solid model files.<br><br> | ||
+ | Click on the previous path to use, and the folder tree on the left will open the new folder. | ||
+ | </td> | ||
+ | <td width=500> | ||
+ | [[image:vtube-1.93_PreviousPaths.png|400px]]<br><br></td> | ||
</tr> | </tr> | ||
</table> | </table> | ||
Line 46: | Line 87: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=400> | <td width=400> | ||
− | * | + | |
+ | * Updated the Chinese translation. | ||
+ | * Updated the German translation. | ||
+ | |||
+ | |||
</td> | </td> | ||
<td width=300> | <td width=300> |
Latest revision as of 18:05, 23 July 2014
Revision 1.93
|
- See VTube-LASER Customer Support Page to download the latest version.
NEW: Import CSM M3 Bender Files (VTube-STEP Mode)
(The VTube-STEP mode is included with VTube-LASER.) VTube-STEP can now import CSM M3 bender files.
|
NEW: Added the Default Tolerance Value in Part Setup
Some output formats prefer to have a default tolerance built into the export, so now the Default Tolerance value is included in the VTube-LASER Part Setup menu. |
NEW: Added to the Popup Menu to Synchronize End Diameters with Main Diameter
The pop up menus for the Part Setup menu (STEP and LASER modes) now allow for the end diameters to be synchronized with the main diameter. |
NEW: Previous Paths List in Quick Open
Other Changes
|
Other
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER
- See VTube Language Editor