Difference between revisions of "VTube-LASER v1.93"

From ATTWiki
Jump to: navigation, search
(Revision 1.92)
(25px NEW: Added to the Popup Menu to Synchronize End Diameters with Main Diameter)
 
(7 intermediate revisions by one user not shown)
Line 23: Line 23:
  
  
===[[image:Check.jpg|25px]] NEW: Export to Laservision Spreadsheet Format Files ===
+
===[[image:Check.jpg|25px]] NEW: Import CSM M3 Bender Files (VTube-STEP Mode)===
 +
[[image:vtube-step-1.93_csm_m3_import_button.png]]
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
<td width=400>
+
<td width=300>
'''Note: This feature is in [[VTube-STEP]], which is included with VTube-LASER.'''<br><br>
+
(The VTube-STEP mode is included with VTube-LASER.)  VTube-STEP can now import CSM M3 bender files.<br><br>
The Eaton Leonard Laservision measuring center can import CSV (Comma Separated Value) files built in an Excel spreadsheet. This version of VTube (STEP mode) can now export to this format.<br><br>
+
* Import the centerline XYZ data.
[[image:vtube-step-1.92_export_laservision.png|400px]]<br><br>
+
* Or import the YBC data.<br><br>
* Include qualification tolerance in the export.<br><br>
+
[[image:vtube-step-1.93_csm_m3_import_radiobuttons.png|300px]]<br><br>
* Automatically show CSV file in a text editor for inspection.<br><br>
+
* Other values imported are:
* Automatically load data into Excel if Excel is available on your system.<br><br>
+
** Diameter
[[image:vtube-step-1.92_export_direct_excel.png|400px]]<br><br>
+
** Wall Thickness
 +
** Pre Length (Start Length)
 +
** End Length
 +
** Cut Length
 +
** Pipe Material Note
 
</td>
 
</td>
 
<td width=500>
 
<td width=500>
[[image:laservision_measuring_center.png|300px]]<br><br>
+
[[image:vtube-step-1.93_csm_m3_importfeature.png|400px]]
[[image:laservision_import_el_csv.png|400px]]<br><br>
+
 
</td>
 
</td>
 +
</tr>
 +
</table>
 +
 +
===[[image:Check.jpg|25px]] NEW: Added the Default Tolerance Value in Part Setup  ===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 +
Some output formats prefer to have a default tolerance built into the export, so now the Default Tolerance value is included in the VTube-LASER Part Setup menu.<br><br>
 +
</td>
 +
<td width=500>
 +
[[image:vtube-1.93_DefaultTolerance_PartSetup.png|400px]]
 +
</td>
 +
</tr>
 +
</table>
 +
 +
===[[image:Check.jpg|25px]] NEW: Added to the Popup Menu to Synchronize End Diameters with Main Diameter  ===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 +
The pop up menus for the Part Setup menu (STEP and LASER modes) now allow for the end diameters to be synchronized with the main diameter.<br><br>
 +
</td>
 +
<td width=400>
 +
[[image:vtube-1.93_SyncEndDiametersPopup.png|400px]]<br><br>
 +
[[image:vtube-1.93_EndDiametersAfter.png|400px]]
 +
</td>
 +
</tr>
 +
</table>
 +
 +
===[[image:Check.jpg|25px]] NEW: Previous Paths List in Quick Open ===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 +
The Quick Open dialog now has a pull-down list that shows all the recent previous paths used to load VTube project files or imported solid model files.<br><br>
 +
Click on the previous path to use, and the folder tree on the left will open the new folder.
 +
</td>
 +
<td width=500>
 +
[[image:vtube-1.93_PreviousPaths.png|400px]]<br><br></td>
 
</tr>
 
</tr>
 
</table>
 
</table>
Line 46: Line 87:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=400>
 
<td width=400>
* Also in VTube-STEP: The SMI export dialog now properly saves the last SMI export path.<br><br>
+
 
 +
* Updated the Chinese translation.
 +
* Updated the German translation.
 +
 
 +
 
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>

Latest revision as of 18:05, 23 July 2014

Vtube-laser logo.jpg

Revision 1.93


Vtube-laser 1.89 mainscreen.png





Check.jpg NEW: Import CSM M3 Bender Files (VTube-STEP Mode)

Vtube-step-1.93 csm m3 import button.png

(The VTube-STEP mode is included with VTube-LASER.) VTube-STEP can now import CSM M3 bender files.

  • Import the centerline XYZ data.
  • Or import the YBC data.

Vtube-step-1.93 csm m3 import radiobuttons.png

  • Other values imported are:
    • Diameter
    • Wall Thickness
    • Pre Length (Start Length)
    • End Length
    • Cut Length
    • Pipe Material Note

Vtube-step-1.93 csm m3 importfeature.png

Check.jpg NEW: Added the Default Tolerance Value in Part Setup

Some output formats prefer to have a default tolerance built into the export, so now the Default Tolerance value is included in the VTube-LASER Part Setup menu.

Vtube-1.93 DefaultTolerance PartSetup.png

Check.jpg NEW: Added to the Popup Menu to Synchronize End Diameters with Main Diameter

The pop up menus for the Part Setup menu (STEP and LASER modes) now allow for the end diameters to be synchronized with the main diameter.

Vtube-1.93 SyncEndDiametersPopup.png

Vtube-1.93 EndDiametersAfter.png

Check.jpg NEW: Previous Paths List in Quick Open

The Quick Open dialog now has a pull-down list that shows all the recent previous paths used to load VTube project files or imported solid model files.

Click on the previous path to use, and the folder tree on the left will open the new folder.

Vtube-1.93 PreviousPaths.png

Check.jpg Other Changes

  • Updated the Chinese translation.
  • Updated the German translation.


Other