Line 21: Line 21:
  
  
===[[image:Check.jpg|25px]] NEW - Large Green LED to Show Measuring Center Monitoring===
+
===[[image:Check.jpg|25px]] NEW - Communications Transfers No Longer Change the BLM Radius Levels===
 
<table width=700>
 
<table width=700>
  
 
<tr>
 
<tr>
 
<td width=300>
 
<td width=300>
A new larger green LED port indicator to show that Benderlink is monitoring for measuring center communications is added to the interface.<br><br>
+
Setting or changing BLM radius levels could easily cause radius level mix ups during corrections loops.  The radius levels are no longer touched or changed during transfer. <br><br>
It is also possible to click on the LED to toggle the measuring center monitor state.
+
Not setting the radius levels is no problem - since corrections loops targets the LRA data only anyway.
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:benderlinkblm_v5.3_large_led.png|400px]]
+
[[image:blinkblm_electric_verticalshift.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 37: Line 37:
 
<br><br>
 
<br><br>
  
===[[image:Check.jpg|25px]] NEW - Communications Transfers No Longer Change the BLM Radius Levels===
+
===[[image:Check.jpg|25px]] NEW - Switch for "Do Not Allow Measuring Center to Change End Lengths"===
 
<table width=700>
 
<table width=700>
  
 
<tr>
 
<tr>
 
<td width=300>
 
<td width=300>
Setting or changing BLM radius levels could easily cause radius level mix ups during corrections loopsThe radius levels are no longer touched or changed during transfer. <br><br>
+
During CORRECTION of parts with extra material on the ends, it is helpful to not allow the end lengths to changeThis keeps the carriage in approximately the same start position even after corrections are applied.<br><br>
Not setting the radius levels is no problem - since corrections loops targets the LRA data only anyway.
+
This version of Benderlink now includes this checkbox switch to turn this feature on or off.
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:blinkblm_electric_verticalshift.png|400px]]
+
[[image:blinkblm_donotallowmeasuringcenterchangeendlengths.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 53: Line 53:
 
<br><br>
 
<br><br>
  
===[[image:Check.jpg|25px]] NEW - Switch for "Do Not Allow Measuring Center to Change End Lengths"===
+
===[[image:Check.jpg|25px]] ENHANCED - The Communications Protocol is Enhanced for LASERVISION Windows Version===
 
<table width=700>
 
<table width=700>
  
 
<tr>
 
<tr>
 
<td width=300>
 
<td width=300>
During CORRECTION of parts with extra material on the ends, it is helpful to not allow the end lengths to changeThis keeps the carriage in approximately the same start position even after corrections are applied.<br><br>
+
The internal communications logic was enhanced to work properly with Windows versions of LASERVISION(It already worked with DOS versions of LASERVISION.)<br><br>
This version of Benderlink now includes this checkbox switch to turn this feature on or off.
+
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:blinkblm_donotallowmeasuringcenterchangeendlengths.png|400px]]
+
[[image:vector_tube_data_center.jpg|400px]]<br>
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 69: Line 68:
 
<br><br>
 
<br><br>
  
===[[image:Check.jpg|25px]] ENHANCED - The Communications Protocol is Enhanced for LASERVISION Windows Version===
+
 
 +
===[[image:Check.jpg|25px]] NEW - Large Green LED to Show Measuring Center Monitoring===
 
<table width=700>
 
<table width=700>
  
 
<tr>
 
<tr>
 
<td width=300>
 
<td width=300>
The internal communications logic was enhanced to work properly with Windows versions of LASERVISION. (It already worked with DOS versions of LASERVISION.)<br><br>
+
A new larger green LED port indicator to show that Benderlink is monitoring for measuring center communications is added to the interface.<br><br>
 +
It is also possible to click on the LED to toggle the measuring center monitor state.
 
</td>
 
</td>
 
<td width=400>
 
<td width=400>
[[image:vector_tube_data_center.jpg|400px]]<br>
+
[[image:benderlinkblm_v5.3_large_led.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 83: Line 84:
 
</table>
 
</table>
 
<br><br>
 
<br><br>
 +
  
 
===[[image:Check.jpg|25px]] NEW - Click on LEDs to Toggle to Measuring Center Monitoring===
 
===[[image:Check.jpg|25px]] NEW - Click on LEDs to Toggle to Measuring Center Monitoring===

Latest revision as of 22:03, 14 October 2015

Benderlink blm logo.jpg

Revision 5.3

Benderlinkblm v5.3 screen.png






Check.jpg NEW - Communications Transfers No Longer Change the BLM Radius Levels

Setting or changing BLM radius levels could easily cause radius level mix ups during corrections loops. The radius levels are no longer touched or changed during transfer.

Not setting the radius levels is no problem - since corrections loops targets the LRA data only anyway.

Blinkblm electric verticalshift.png



Check.jpg NEW - Switch for "Do Not Allow Measuring Center to Change End Lengths"

During CORRECTION of parts with extra material on the ends, it is helpful to not allow the end lengths to change. This keeps the carriage in approximately the same start position even after corrections are applied.

This version of Benderlink now includes this checkbox switch to turn this feature on or off.

Blinkblm donotallowmeasuringcenterchangeendlengths.png



Check.jpg ENHANCED - The Communications Protocol is Enhanced for LASERVISION Windows Version

The internal communications logic was enhanced to work properly with Windows versions of LASERVISION. (It already worked with DOS versions of LASERVISION.)

Vector tube data center.jpg




Check.jpg NEW - Large Green LED to Show Measuring Center Monitoring

A new larger green LED port indicator to show that Benderlink is monitoring for measuring center communications is added to the interface.

It is also possible to click on the LED to toggle the measuring center monitor state.

Benderlinkblm v5.3 large led.png




Check.jpg NEW - Click on LEDs to Toggle to Measuring Center Monitoring

You can now click on either LED indicator to toggle monitoring for the measuring center commmands.

Benderlinkblm v5.3 both leds.png



Check.jpg FIXED - Ping Port Confirmation Works in Windows 7, 8, 8.1, 10

This feature allows Benderlink to ping for a serial device server before opening a virtual port.

The feature worked in older Windows - but did not work in Windows 7 and higher. Now it works in the newer Windows versions too.

Blinkblm pingportconfirmation.png



Check.jpg NEW - Message Warning for COM Ports That Cannot Open

When a COM port to the measuring center cannot open, Benderlink now displays a message that a problem occurred.