Difference between revisions of "Reverse the Tube Ends"

From ATTWiki
Jump to: navigation, search
(Reset the Reversed Point Labels)
 
(7 intermediate revisions by one user not shown)
Line 23: Line 23:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
It is often necessary to reverse the tube ends in order to bend the part from the other end of the tube.  To reverse the tube ends, you can right click on the XYZ grids for the MASTER or MEASURED data and click on '''Reverse the Tube Ends'''.
+
It is often necessary to reverse the tube ends in order to bend the part from the other end of the tube.  To reverse the tube ends, you can right click on the XYZ grids for the MASTER or MEASURED data and click on '''Reverse XYZ Data'''.
 
</td>
 
</td>
 
<td>
 
<td>
[[image:vtube-laser_v2.5_reverse_tubeends.png|600px]]
+
[[image:vtube-laser_v2.5_reverse_tubeends.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 33: Line 33:
 
<br>
 
<br>
  
 
+
== Reversed Point Labels==
== About Supravision Files==
+
  
 
<table>
 
<table>
Line 40: Line 39:
 
<tr valign=top>
 
<tr valign=top>
 
<td width=300>
 
<td width=300>
Supravision files usually have a filename extension of $$$.<br><br>
+
When you reverse the XYZ rows, VTube will also reverse the point labels.<br><br>With the point labels reversed, it is a good idea to look at the END LABELS rather than the POINT LABELS to determine which end to measure first.<br><br>
They are text files that contain part setup, XYZ, and LRA data usually.<br><br>
+
See the effect in the image on the right.  The END A label is at point 9 in this part after a reverse of the XYZ data.</td>
They were used by [[Supravision]] software to save and load Supravision project files - so they contain a lot of data that VTube understands.<br><br>
+
<td>
(Supravision software was retired a few years ago by ROMER. It was one of the standards in the industry for decades.)
+
[[image:vtube-laser_2.5_reverse_point_labels.png|400px]]
 
</td>
 
</td>
 +
</tr>
 +
<tr>
 +
</table>
 +
<br>
 +
 +
 +
== Reset the Reversed Point Labels==
 +
 +
<table>
 +
 +
<tr valign=top>
 +
<td width=300>
 +
You can reset the point labels from being reversed with the XYZ reverse feature.<br><br>
 +
Right click on the XYZ grid and the click on '''Reset Point Labels'''.</td>
 
<td>
 
<td>
[[image:Svwin.png|600px]]
+
[[image:vtube_v2.5_reset_point_ labels.png|400px]]
 +
[[image:vtube_v2.5_effect_of_reset_point_labels.png|400px]]<br><br>
 +
[[image:vtube-laser_v2.5_tubeimage_with_pointlabels.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>

Latest revision as of 15:48, 13 April 2016

Vtube-step logo 1.96.png Vtube-laser logo 1.96.png

VTS2 SplashScreen.png
Vtl screen hd scanner without logo.png



Reverse the Tube Ends

It is often necessary to reverse the tube ends in order to bend the part from the other end of the tube. To reverse the tube ends, you can right click on the XYZ grids for the MASTER or MEASURED data and click on Reverse XYZ Data.

Vtube-laser v2.5 reverse tubeends.png


Reversed Point Labels

When you reverse the XYZ rows, VTube will also reverse the point labels.

With the point labels reversed, it is a good idea to look at the END LABELS rather than the POINT LABELS to determine which end to measure first.

See the effect in the image on the right. The END A label is at point 9 in this part after a reverse of the XYZ data.

Vtube-laser 2.5 reverse point labels.png



Reset the Reversed Point Labels

You can reset the point labels from being reversed with the XYZ reverse feature.

Right click on the XYZ grid and the click on Reset Point Labels.

Vtube v2.5 reset point labels.png Vtube v2.5 effect of reset point labels.png

Vtube-laser v2.5 tubeimage with pointlabels.png