− | ==CRIPPA UII Control software== | + | ==CRIPPA UII Control software Version 3== |
<table width=700> | <table width=700> | ||
<tr> | <tr> | ||
<td> | <td> | ||
− | The CRIPPA Windows software allows for complete programming of bender setup. | + | The CRIPPA Windows software allows for complete programming of bender setup.<br><br> |
+ | This is an older version 3.2 of the CRIPPA UII. | ||
</td> | </td> | ||
<td> | <td> | ||
Line 23: | Line 24: | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | |||
+ | ==CRIPPA UII Control software version EVO II== | ||
+ | <table width=700> | ||
+ | <tr> | ||
+ | <td> | ||
+ | This is the screen from the Evo II generation of Crippa UII software (circa 2017). Changes made by VTube-LASER can be viewed in the YBC grid on this page.<br><br> | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:crippa_520_uii_screen_evoII.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | <tr> | ||
+ | <td> | ||
+ | This is the main screen for the CRIPPA HMI. The UII screen (shown above) is loaded from the bottom toolbar button in this screen.<br><br> | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:crippa_evoII_hmi_point_to_UIIbutton.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | </table> | ||
+ | |||
+ | |||
<br><br> | <br><br> | ||
Line 29: | Line 54: | ||
<tr> | <tr> | ||
<td width=300 valign=top> | <td width=300 valign=top> | ||
− | VTube-LASER communicates with the CRIPPA UII software using the Supravision Network protocol.<br><br> | + | [[VTube-LASER]] communicates with the newer CRIPPA UII software using the Supravision Network protocol.<br><br> |
Communications are fully bidirectional - you can send and recall data.<br><br> | Communications are fully bidirectional - you can send and recall data.<br><br> | ||
It is possible to send new part data to the Crippa, and to correct existing parts easily with the Crippa communications.<br><br> | It is possible to send new part data to the Crippa, and to correct existing parts easily with the Crippa communications.<br><br> | ||
− | (Crippa added this capability in late 2014.) | + | (Crippa added this capability in late 2014.) See [[VTube Communication for CRIPPA Supravision]] for details.<br><br> |
+ | [[VTube-LASER]] can also communicate with older CRIPPA SIEMENS SINUMERIK controls by building the CRIPPA MPF data files. See [[VTube Communication for CRIPPA MPF]] for details. | ||
</td> | </td> | ||
<td width=500> | <td width=500> | ||
Line 43: | Line 69: | ||
<br><br> | <br><br> | ||
− | + | ==[[VTube-STEP]] Support for Newer CRIPPA Bender SPF Files== | |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | ==[[VTube-STEP]] Support for CRIPPA Bender SPF Files== | + | |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | [[VTube-STEP]] can export Crippa export capability allows for easy export to Crippa UII software. The format is a text file that is compatible with most | + | For newer benders, [[VTube-STEP]] can export Crippa export capability allows for easy export to Crippa UII software. The format is a text file that is compatible with most CRIPPA benders that were released in early 2012 and on.<br><br> |
− | [[image:vtube_step_1.77.4_crippa_export.jpg|400px]]<br> | + | [[image:vtube_step_1.77.4_crippa_export.jpg|400px]]<br><br> |
− | + | ||
− | + | ||
</td> | </td> | ||
<td width=500> | <td width=500> | ||
Line 82: | Line 83: | ||
</table> | </table> | ||
− | + | ==[[VTube-STEP]] Support for Legacy CRIPPA Bender MPF Files== | |
− | + | ||
− | ==[[VTube-STEP | + | |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | For CRIPPA benders | + | For older CRIPPA SIEMENS SINUMERIK benders, VTube-STEP can build MPF files. (As of VTube version 2.7, December of 2016)<br><br> |
− | + | See [[VTube Communication for CRIPPA MPF]] for details.<br><br> | |
+ | [[image:vtube-step_2.7 export crippa mpf.png|400px]]<br><br> | ||
</td> | </td> | ||
Line 111: | Line 111: | ||
==Other Pages== | ==Other Pages== | ||
− | |||
* See [[VTube-LASER]] | * See [[VTube-LASER]] | ||
* See [[VTube-STEP]] | * See [[VTube-STEP]] | ||
+ | * See [[VTube Communication for CRIPPA MPF]] for a tutorial on communications setup and use |
Latest revision as of 14:58, 11 August 2017
CRIPPA benders are built in Italy and marketed worldwide. Customers report that they like these benders very much. They are often all electric with all actuators servo-controlled. |
Contents |
CRIPPA UII Control software Version 3
The CRIPPA Windows software allows for complete programming of bender setup. |
CRIPPA UII Control software version EVO II
This is the screen from the Evo II generation of Crippa UII software (circa 2017). Changes made by VTube-LASER can be viewed in the YBC grid on this page. |
|
This is the main screen for the CRIPPA HMI. The UII screen (shown above) is loaded from the bottom toolbar button in this screen. |
VTube-LASER Support for Crippa Bender Setup and Corrections
VTube-LASER communicates with the newer CRIPPA UII software using the Supravision Network protocol. |
VTube-STEP Support for Newer CRIPPA Bender SPF Files
For newer benders, VTube-STEP can export Crippa export capability allows for easy export to Crippa UII software. The format is a text file that is compatible with most CRIPPA benders that were released in early 2012 and on. |
VTube-STEP Support for Legacy CRIPPA Bender MPF Files
For older CRIPPA SIEMENS SINUMERIK benders, VTube-STEP can build MPF files. (As of VTube version 2.7, December of 2016) |
Contact Information
CRIPPA USA Distributor
Chris Harrison
Tube Process Technology LLC
4343 SKUSA DR
BRIGHTON, MI 48116
Phone (810) 599-1972
E-Mail: [email protected]
Other Pages
- See VTube-LASER
- See VTube-STEP
- See VTube Communication for CRIPPA MPF for a tutorial on communications setup and use